Two points the document got wrong. The stable branch is main, not
master: the remote has never had a master. And the promotion chain was
written as if it existed, while landing-silo and experimental-silo were
created only today, the first as empty branches off main.
Nothing else in the document is touched.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Committed verbatim from the working tree, where it had been sitting
uncommitted. Written by Patrick, not by the agent: this commit only puts
it under version control so the promotion chain it describes can be
corrected against reality in the next one.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
First content of the promotion chain. Brings the vendored SunSpec plugin,
the Fronius vendor and its multi unit ID support: one froniusConnection
thing now carries two SunSpecConnection objects, inverter and Smart Meter
on separate unit IDs behind the same host and port.
Verified before merging: 60 offline tests green, plus 8 green against the
bench SunSpec simulator in froniusgen24-sunspec mode.
Note: the branch was cut from the abbterra TCP line, so this merge also
brings three abbterra commits that were never in main.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The suite captured a stack local of initTestCase() by reference in two
lambdas that outlive it. Once the function returned they wrote into a
stack slot reused by later frames, corrupting the running test: a
QSignalSpy reported a phantom emission, reading its recorded arguments
segfaulted, and the count changed when unrelated locals were added. Both
observed failures came from that, not from the plugin. The two flags are
members now.
Covers the two remaining claims the offline suites cannot reach: a meter
slave ID of 0 opens no second connection against a real device, and
losing the meter connection leaves the parent connected and the inverter
data flowing, marking only the meter child disconnected.
That last test drives one explicit block read first. This bench replaces
the plugin timer with a null object, on purpose, so nothing would
otherwise ever mark a child connected and the cut would prove nothing.
Run against the bench simulator: 8 tests, 8 green. Each of the two
corrections was confirmed able to fail by reintroducing its pre-F3 form.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The whole point of keeping the meter connection in a hash of its own was
that not a line of the generic and solarEdge vendors would change.
Checks it rather than claiming it: a stored solarEdge connection, whose
behaviour no suite covered until now, must still end up with exactly one
connection, as must a generic one.
Also records the connection a discovery came from in
processDiscoveryResult() rather than in the discoveryFinished handler.
The initial setup calls it from a second handler on the same signal, so
recording it there made the orphan sweep depend on the order Qt happens
to invoke the two.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The two most certain defects of the multi unit ID work are invisible to
the offline suites, because they only appear once a discovery has
actually run: the orphan sweep deleting the children of the other
connection, and the aggregation of the connected state.
This suite mounts the plugin behind a real ThingManager against a real
device. It is deliberately not a testcase, so "make check" never runs
it, but it is still built so it cannot rot unnoticed. Without
SUNSPEC_TEST_HOST every test skips, and no address is written into the
repository: the address of a real installation is customer data.
NOT YET RUN against hardware. It needs the address of a GEN24 and, given
the polling rate guidance, a deliberate decision to point it at a
customer inverter.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
processDiscoveryResult() makes child things disappear when their model
is no longer announced. It used to confront them with the models of the
one connection that had just finished discovering, which is only half of
the picture on a thing carrying two: the inverter discovery would delete
the meter child, and the meter discovery the inverter and storage ones,
on every single reconnect.
The sweep now waits for every connection of the parent to have reported
a successful discovery, then confronts the children with the union of
their models. A grace period releases it if a connection never reports,
so a hung discovery cannot freeze the cleanup for good.
That grace period is inferred, not measured: it is set generously
because sweeping too late leaves a stale child showing as disconnected,
while sweeping too early deletes a thing of the user. Recorded as D-2 in
DIVERGENCES.md with what to measure to replace it.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
A GEN24 answers for the inverter on unit ID 1 and for its Smart Meter on
unit ID 200 by default, behind the same host and port. One thing now
carries two SunSpecConnection objects, the second one driven by the
meterSlaveId parameter that until now no line of C++ ever read.
The meter connection is created during setup but left idle: it is only
brought up once the primary connection has finished discovering, so the
two never handshake at the same time towards the same inverter. An
absent meter never fails the pairing, since a GEN24 without a Smart
Meter is a legitimate installation and the parameter has a non zero
default the user did not choose.
thingRemoved() and the reconfigure path now dispose of both connections
through a single entry point. Their else if chain used to stop at the
primary one, which left the meter connection outliving its thing with an
open socket and signals pointing at a destroyed Thing.
Child things look their model up across every connection of their
parent. The two connections of a GEN24 never announce the same model ID,
so no discriminator has to be persisted.
Adds a test suite instantiating the plugin behind a real ThingManager
with two connections. It lives in its own binary because the F1 suite
checks global call counters that extra configured things would falsify.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Takes the slave ID as an argument instead of reading it from the thing,
and takes whether it is the primary connection of that thing. Only the
primary one follows the network monitor, writes the connected state of
the thing and lands in m_sunSpecConnections; a secondary one lands in a
hash of its own.
Child things are updated per connection rather than per parent, resolved
from the model each child is bound to. With a single connection that is
every child of the parent, so nothing changes here yet.
No caller creates a secondary connection at this point: behaviour is
unchanged for all three vendors.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
A GEN24 answers for the inverter on one unit ID and for the Smart Meter
on another, behind the same host and port. Isolate the decision to open
that second connection as a pure function, so it can be pinned down
without nymea, and leave the logging of the refusal to the caller.
Refuses a meter slave ID out of the 0..247 range, treats 0 as "no meter
on this connection" as documented, and refuses a meter slave ID equal to
the inverter one: a second socket on the same unit ID would rediscover
the very same models and duplicate every child thing. That last case is
reachable, since the discovery writes the scanned slave ID into the
thing parameter.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
AC-7 asks for the meterSlaveId parameter to be advanced. That property
does not exist on nymea 1.15.2 param types: the metadata verifier
rejects unknown fields, so adding it makes the whole plugin fail to
load rather than merely hiding a parameter.
Measured by loading the plugin JSON, with and without the flag, into a
PluginMetadata linked against the installed libnymea, rather than read
from an upstream tree that may differ from the package.
Also records the three other divergences the multi unit ID work runs
into, two of which predate it.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
setupThing() only knew about sunspecConnection and solarEdgeConnection, so a
froniusConnection thing fell into the final Q_ASSERT_X. In a release build the
assert is compiled out, setupThing() returns without calling info->finish(),
and the pairing hangs until the setup times out - with no message at all. In a
debug build nymead dies on the assert instead.
Take the same branch as the two vendors that already work: createConnection()
already reads the slave ID and picks the byte order for froniusConnection, so
no new logic is needed.
postSetupThing() and thingRemoved() are unchanged on purpose. The former only
special cases solarEdgeConnection, for the battery search a Fronius must not
run, and registers the refresh timer for every thing. The latter is keyed on
m_sunSpecConnections, which createConnection() now populates for Fronius as
well.
Makes the four cases of tst_sunspecplugin pass.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The existing suite only exercises free functions and the plugin JSON, so it
cannot see whether a thing class is dispatched at all. A thing class missing
from the dispatch in setupThing() falls into the final Q_ASSERT_X: in a debug
build the process dies, in a release build the assert is compiled out and
setupThing() returns without ever calling info->finish(), leaving the pairing
stuck with no message.
Split the tests into two suites. The logic one keeps its former scope and its
single dependency on libnymea-sunspec. The new one instantiates the plugin
behind the real ThingManager of libnymea-core and a faked HardwareManager, so
the dispatch of setupThing(), postSetupThing() and thingRemoved() is covered.
No network access takes place: the faked monitor is never reachable, so the
plugin never attempts a Modbus connection.
The four new cases fail: froniusConnection is not dispatched yet.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Adds a fronius vendor and a froniusConnection thing class alongside the
generic sunspec and solarEdge ones, following the SolarEdge mechanism but
none of its workarounds - no proprietary battery block and no PV
production computed by difference, since the GEN24 exposes model 160.
FroniusRules holds the vendor decisions as pure functions:
- discovery only keeps devices announcing Fronius as manufacturer;
- the byte order is the SunSpec default, not the forced big endian that
is specific to SolarEdge, and no endianness parameter is exposed;
- meterSlaveId defaults to 200, 0 meaning no meter on this connection;
- a hard 7 s floor on the poll interval. Polling faster can push the
inverter offline towards the vendor portal, and recovery needs an
AC+DC power cycle on site, so this is a guard in the code rather than
a configurable default;
- the registers the inverter accepts and then silently ignores are
refused before anything reaches the wire;
- the six HEMS battery modes map onto ChaGriSet, StorCtl_Mod, InWRte and
OutWRte, negative meaning charge;
- model 160 blocks are classified by IDStr, never by index: on a three
or four MPPT inverter the battery blocks are not in position 3 and 4.
Storages under a Fronius connection default revertTime to 300 s.
Setpoints now reread the scale factor before writing and read the written
registers back afterwards, reporting a mismatch through a new
controlHealthy state - the only defence against writes that are accepted
and then ignored without a Modbus exception.
Byte order and the revert timer semantics on model 124 are inferences, not
measurements; see specs/fronius-sunspec.md, H-2 and H-3.
setInOutWRteRvrtTms() existed but was never called. InOutWRte_RvrtTms is
the delay after which the inverter drops the setpoint and resumes its
native behaviour. Left at 0, a setpoint stays active indefinitely, HEMS
stopped, network lost or process crashed included - the battery stays
where the last command put it.
Add a per-thing revertTime parameter, 0..28800 s, defaulting to 0 so the
generic vendor keeps its current behaviour, and route every setpoint
through SunSpecStorageLogic::planSetpoint(). The plan orders the writes -
ChaGriSet, StorCtl_Mod, then the rates - and appends the revert timer
last, so the timer never starts counting against a setpoint that has not
been written yet.
Writes are issued sequentially rather than in parallel: the order is part
of the contract with the hardware.
onStorageBlockUpdated() fed chargingRate from wChaGra() and dischargingRate
from wDisChaGra(). Those are the gradients, in percent of WChaMax per
second, and read only on several inverters. The matching actions write
InWRte and OutWRte, in percent of WChaMax. The user wrote one quantity and
read back another.
Feed the two rate states from inWRte() and outWRte(), and keep the
gradients under names that cannot be mistaken for setpoints:
chargeGradient and dischargeGradient, read only.
enableDischarging was never reconciled either, while enableCharging was.
It stayed frozen on the last written value and drifted silently as soon as
the inverter changed StorCtl_Mod on its own. Reconcile both flags.
The mapping moves into SunSpecStorageLogic so it can be exercised on a
register dump without a running nymea.
chargingRate and dischargingRate map onto InWRte and OutWRte of model 124,
which are int16 setpoints ranging from -100.00 to +100.00 percent of
WChaMax. Declaring them as 0..100 makes a forced charge structurally
inexpressible: nymea rejects the negative action parameter before it ever
reaches the plugin.
Also fixes the default value, which was the boolean false on an int state.
One test per AC of specs/fronius-sunspec.md, named test_AC_<n>_<what>.
Definition criteria (value ranges, thing classes, defaults) are checked by
re-reading integrationpluginsunspec.json. Behaviour criteria run either on
a model 124 register dump fed to the real libnymea-sunspec model, or on the
pure logic units the plugin is about to grow.
All red at this point: sunspecstoragelogic and froniusrules do not exist
yet, so the suite does not compile. That is the expected starting state.
AC-1..AC-4 are the four upstream anomalies of the generic sunspec vendor
(setpoint range, read/write mismatch on the rate states, enableDischarging
never reconciled, revert timer never written).
AC-5..AC-15 are the Fronius-specific behaviour: manufacturer filter, byte
order, connection parameters, polling floor, forbidden writes, the HEMS
intent to register table, scale factor reread, readback verification and
the model 160 block classification.
Points the design contract leaves open are recorded as explicit working
hypotheses (H-1..H-6) rather than blocking on them.
Vendor the sunspec plugin into this repo so the Fronius work and the
upstream storage fixes can live here. Sources only: build artefacts and
generated plugininfo headers are excluded.
libnymea-sunspec is deliberately NOT vendored - the plugin must stay
rebasable on upstream nymea, so it links against libnymea-sunspec-dev.
sunspec.pri resolves it via pkg-config, with a NYMEA_SUNSPEC_PATH
override for a local sysroot, mirroring modbus.pri.
See sunspec/VENDORED.md.
Follow-up to the etm1 fixes, driven by live debugging against a real ABB
Terra AC 7 kW behind a Waveshare RS485->TCP gateway (192.168.1.132, slave 2):
- etm3: disable TCP auto-discovery (createMethods = "user" only). Discovery
blind-scans the LAN and SIGSEGVs nymead as soon as any Modbus device answers
:502 with an exception response. The crash is in the generated reachability
handler (abbterramodbustcpconnection.cpp:2062 dereferences the check-reachable
reply after it is freed); it could not be fixed from the discovery code alone.
A gateway's slave id can't be discovered anyway, so manual add is required.
- etm2: still defer/guard AbbTerraTcpDiscovery::cleanupConnection() teardown
(kept for correctness even though discovery is now off by default).
- etm4: setupTcpThing() never called connectDevice(), so manual setup hung until
timeout. Start the connection when the network monitor reports the device.
- etm5: decode the serial-number and firmware register fields as BCD per ABB
spec §5.1 (0x46 = week 46, not 70; 0x22 = 22 kW). The binary reading rejected
real chargers ("does not match the ABB Terra AC Modbus register map").
Verified end to end: charger adds cleanly (TACW7-4-4624-S0034), states poll and
actions execute, no SIGSEGV. The underlying discovery/generated-code crash is
tracked separately.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Two coupled fixes so the ABB Terra AC can be added over Modbus TCP:
- Restore checkReachableRegister ("serialNumber") in the register JSON.
The libnymea-modbus 1.15 code generator *requires* it — without it the
connection classes (abbterramodbustcpconnection.h) are never generated and
the plugin fails to build. Reverts the false lead in b23a9a2. The register
is valid: mbpoll confirms holding reg 16384 (uint64) responds at slave 2.
- Fix a use-after-free in AbbTerraTcpDiscovery::cleanupConnection() that
SIGSEGV'd nymead during network discovery whenever any Modbus device on the
LAN answered on :502 with an exception (e.g. "illegal data address"). The
method is invoked from several of the connection's own signals; it now
bails out on the second (re-entrant) call and disconnects the connection's
signals before disconnectDevice(), so the teardown can no longer re-enter
while the QModbusReply "finished" handler is still dereferencing the reply.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The status block (12 registers × 2 words = 24 words) was read as a
single Modbus request, producing a 53-byte response that overflows the
RT38B01 433 MHz radio module's 31-byte frame limit.
Dissolve the status block into individual registers with
readSchedule:update so queuedRequests sends them one at a time
(max 9 bytes per response). The deviceInfo init block (8 words → 21
bytes) is left untouched.
Bump to 1.15.0+etm6.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
reachableChanged(true) never fires within the nymea setup timeout when
the RTU link is slow (e.g. 433 MHz radio relay). Add a fallback:
trigger initialize() immediately if master is already connected
(QTimer::singleShot 500 ms), and also on master::connectedChanged.
The existing reachableChanged path is kept for TCP-style RTU adapters.
Bump to 1.15.0+etm5.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Diagnostic tcpdump : le plugin ouvrait/fermait la socket Modbus TCP à
chaque cycle de poll, générant 6-7 paquets SYN consécutifs qui saturaient
l'ESP32 WiFi de la borne (timeouts en boucle). mbpoll avec une connexion
persistante = 0 % d'échec.
Corrections :
- connectDevice() : guard "si déjà connecté → no-op" (élimine le warning
"already in ConnectedState" et les FIN/RESET parasites).
- onConnectionStateChanged(true) : appelle initialize() directement au lieu
de setReachable(true) — évite la ré-entrée initialize() via reachableChanged.
- initialize() : setReachable(true) uniquement au succès, après lecture
MinIntensity/MaxIntensity ; guard || m_updating ajouté.
- update() : guard || m_initializing ajouté (pas de poll concurrent avec init).
- Timer : if (!master->update()) master->connectDevice() — le socket reste
ouvert tant que la connexion TCP est active ; connectDevice() n'est appelé
que quand le TCP est réellement coupé.
- initializationFinished(thing) : master->update() immédiat après reconnect.
- reachableChanged handler : suppression de l'appel à initialize() (déplacé).
Résultat attendu tcpdump : 1 seul SYN à l'établissement, puis uniquement
des échanges Modbus (P. length 12/13) toutes les 30 s, aucun FIN/RESET.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- Decode SlaveError (reg 0x0BC5) with full table (codes 0-10) into new
slaveErrorMessage state; code 04 (WiFi reconnect) also surfaces in
statusMessage for immediate SAV visibility.
- Add L1/L2/L3 phase powers (regs 0x0BD9-0x0BDB, confirmed hw) as
diagnostic states polled every 30 s.
- Add RegChargeTime (0x0BC6) to enum for completeness (not yet exposed).
- Collapse debian/changelog to single 1.15.0+etm1 entry (new plugin).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
The Trydan ESP32 WiFi stack saturates under nymea's periodic ICMP pings
(observed: latency > 14 s, Modbus timeouts, charger drops off).
Changes:
- NetworkDeviceMonitor removed entirely from setupThing() and thingRemoved().
The charger is expected to have a DHCP-reserved IP (documented in code).
Address comes from trydanThingAddressParamTypeId param — already the correct
path after the previous setup fix.
- Connectivity now derives from Modbus poll success/failure only (reachable()
from TrydanModbusTcpMaster), NOT from network ping. A ping response does
not imply Modbus usability on this hardware.
- postSetupThing() timer (30 s): if not reachable, calls connectDevice() for
reconnect; if reachable, calls update(). The 30 s period IS the backoff —
no aggressive retry loop.
- Modbus timeout: 2 s → 5 s (tolerates residual WiFi latency spikes).
- Modbus retries per read: 1 → 0 (abort fast on first timeout; full poll
sequence already aborts at first error via doNextRead).
- k_errorLimit: 5 → 3 (3 × 5 s = 15 s before marking unreachable).
- New state "statusMessage" (QString): set on disconnect with timestamp +
cause ("timeout Modbus — vérifier signal WiFi de la borne"); cleared on
successful poll. Visible in nymea-app; helps SAV without SSH access.
- "networkdevice" removed from JSON interfaces (contract broken without monitor).
Invariants preserved: Big/Big float32 decode, no block read, PauseState+Lock
mirror, PauseDynamic conflict management, writeCompleted address filtering.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Bug: ModbusTcpMaster: device ':502' ConnectionError when adding a trydan
by manual IP (createMethod "user") or after nymead restart before the
NetworkDeviceMonitor completes its ARP scan.
Root cause: TrydanModbusTcpMaster was constructed with
monitor->networkDeviceInfo().address(), which is null at first
registerMonitor() — the monitor only populates its cache after an
asynchronous ARP/mDNS resolution. connectDevice() then ran against
QHostAddress() → ":502".
Fix:
- Read the initial IP from the stored address param (always set at
discovery or user-entry) and use it as the fallback when the monitor
has not yet resolved the address.
- Guard the networkDeviceInfoChanged callback: only call setHostAddress()
when the new address is non-null (the monitor emits transient null info
during its internal refresh cycles).
Order is now: create master with valid address → wire callbacks →
connectDevice(). The monitor update path remains for DHCP renewals.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Build fixes found during first local compilation (qmake6 + g++ -Werror):
1. Logging category: nymea-plugininfocompiler generates 'dcV2C' (uppercase C)
from the JSON vendor name "V2C". All three source files used 'dcV2c'
(lowercase c) — corrected to 'dcV2C' in integrationpluginv2c.cpp,
trydanmodbustcpmaster.cpp, v2ctcpdiscovery.cpp.
2. modbus.pri: hardcoded include(/usr/include/nymea-modbus/modbus-tool.pri)
fails when libnymea-modbus-dev is not system-installed. Changed to a
conditional: checks $$[QT_INSTALL_PREFIX] first, then NYMEA_MODBUS_PATH
override, with a graceful fallback (warning + manual C++17 CONFIG flag).
The v2c plugin has MODBUS_CONNECTIONS empty so the tool loop is a no-op
either way; the fallback is safe.
3. debian/: add powersync-plugin-v2c package entry (control, .install,
changelog entry 1.15.0+etm4).
Build verified: libnymea_integrationpluginv2c.so links against libnymea.so.1,
libnymea-modbus.so.1, Qt6Network/SerialBus/Core, 0 compiler warnings
(with -Werror -Wall -Wextra -std=c++17).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
qMin(32, m_maxIntensity) gives 0 when firmware returns 0 for MaxIntensity
(aberrant value). maxIntensity()==0 then causes every setMaxChargingCurrent
call to be clamped to 0, falling into the <6 A path which pauses charging
silently — the user sees the action succeed but the charger stops.
qBound(6, val, 32) is correct in all cases:
- firmware reports 16 A (mono Trydan) → 16 (real installation limit kept)
- firmware reports 0 (aberrant) → 6 (safe floor, does not claim 32 A)
- firmware reports 65535 (aberrant) → 32 (IEC absolute ceiling)
The real installation limit still comes from MaxIntensity read on the device;
the bounds [6, 32] are only IEC guardrails, not hardcoded defaults.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Étape 1 complete: V2C Trydan nymea plugin (Modbus TCP, status Partial).
Plugin (IntegrationPluginV2c):
- discoverThings: delegates to V2cTcpDiscovery, maps results to
ThingDescriptors; createMethod "user" bypasses discovery.
- setupThing: registers a NetworkDeviceMonitor (IP tracking on DHCP
renewal), creates TrydanModbusTcpMaster, wires reachableChanged →
initialize() → state update on initializationFinished(), then starts
periodic polls on a 30s PluginTimer.
- updateThingStates: ChargeState 0/1/2 → pluggedIn/charging;
power = (PauseState==0 AND Lock==0) per evcc trydan.go Enabled().
- handleDynamicConflict: if Dynamic==1 (V2C internal PV optimizer),
write PauseDynamic=1 to suppress it. NEVER write Dynamic=0 (silences
ChargePower telemetry). Writes only on state transition to minimize
flash wear. cf. github.com/evcc-io/evcc/issues/28047.
- Action "power": writes PauseState then Lock (always in mirror), then
fire-and-forgets PauseDynamic if Dynamic==1. Action handlers filter
writeCompleted by register address to avoid reacting to concurrent
background writes.
- Action "maxChargingCurrent": clamps to [minIntensity, maxIntensity],
writes Intensity. Below 6A → pause instead of invalid setpoint.
JSON (integrationpluginv2c.json):
- ThingClass "trydan" implementing evcharger + connectable + networkdevice.
- settingsTypes: suspendInternalOptimizer (bool, default true) — allows
the user to disable Dynamic conflict management if they want the V2C
PID to remain active alongside the HEMS.
- State "chargeEnergy" exposed as diagnostic only (NOT sessionEnergy) —
firmware reliability on this register is unvalidated; cf. evcc #28047.
Build (v2c.pro):
- MODBUS_CONNECTIONS intentionally empty: the modbus-tool code generator
assumes non-overlapping block reads; leaving it empty skips generation
while still linking nymea-modbus via the PKGCONFIG in modbus.pri.
VendorId 56c3e7bb… is new (no existing V2C vendor in the repo).
PluginId f0692725… is new (generated for this plugin).
PORTING_STATUS_modbus.md documents register sources, the 4 items that
require validation on real hardware, and the "no beta matrix" constraint.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Architecture choice: Modbus TCP has no network discovery mechanism, so
discovery piggybacks on nymea's NetworkDeviceDiscovery (ARP/mDNS scan)
and then probes each host via GET /RealTimeData (V2C Trydan HTTP REST API).
The presence of a "Paused" field in the JSON response is used as a Trydan
fingerprint — it matches the charger model and is absent on generic devices.
cf. evcc charger/trydan.go realTimeData struct.
Probes run concurrently (one QNetworkReply per host) but the sequence
terminates via two independent paths that could both fire:
1. The NetworkDeviceDiscoveryReply::finished callback arms a 3-second
QTimer::singleShot to give outstanding probes time to complete.
2. Each probe completion path checks (m_scanFinished && pendingProbes==0)
and calls finishDiscovery() early if all probes are already done.
A m_finished bool guard prevents double-emission of discoveryFinished()
if both paths fire in quick succession (e.g. all probes complete exactly
as the timer fires).
Manual-entry (createMethod "user") skips discovery entirely; setupThing()
is called directly with the user-supplied IP.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Architecture choice: separate the register map / business logic from the
physical transport. TrydanModbusMaster (abstract QObject) holds:
- the complete ReadRegister / WriteRegister enums with addresses
- float32 Big/Big decode helpers (memcpy pattern, matches pymodbus
BinaryPayloadDecoder byteorder=Endian.Big wordorder=Endian.Big)
- all last-polled cached values accessible via simple getters
TrydanModbusTcpMaster (concrete, Étape 1) wraps libnymea-modbus
ModbusTcpMaster. Each register read is a distinct FC3(addr, 2)
transaction via a recursive runReadSequence/doNextRead pattern —
never a block read, because the V2C firmware's register windows
overlap (0x0BC2 and 0x0BC3 each span 2 registers, so a range read
starting at 0x0BC2 for ≥3 registers returns garbage for the second
value). Writes use FC6 (single uint16, not float).
writeCompleted(quint16 address, bool success) carries the originating
register address so that concurrent background writes (e.g. PauseDynamic
from the conflict manager firing during an action) do not interfere with
action handlers waiting on a specific register's acknowledgement.
0x177E (Dynamic) is intentionally absent from WriteRegister: writing it
to 0 silences ChargePower telemetry even though the charger keeps running.
cf. evcc charger/trydan.go and github.com/evcc-io/evcc/issues/28047.
Étape 2 (RTU) will add TrydanModbusRtuMaster on the same interface;
no changes to plugin or register logic will be required.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>