Bug: ModbusTcpMaster: device ':502' ConnectionError when adding a trydan by manual IP (createMethod "user") or after nymead restart before the NetworkDeviceMonitor completes its ARP scan. Root cause: TrydanModbusTcpMaster was constructed with monitor->networkDeviceInfo().address(), which is null at first registerMonitor() — the monitor only populates its cache after an asynchronous ARP/mDNS resolution. connectDevice() then ran against QHostAddress() → ":502". Fix: - Read the initial IP from the stored address param (always set at discovery or user-entry) and use it as the fallback when the monitor has not yet resolved the address. - Guard the networkDeviceInfoChanged callback: only call setHostAddress() when the new address is non-null (the monitor emits transient null info during its internal refresh cycles). Order is now: create master with valid address → wire callbacks → connectDevice(). The monitor update path remains for DHCP renewals. Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>