Patrick Schurig fe7c15d0b9 abbterra: split status block to respect 31-byte RT38B01 frame limit
The status block (12 registers × 2 words = 24 words) was read as a
single Modbus request, producing a 53-byte response that overflows the
RT38B01 433 MHz radio module's 31-byte frame limit.

Dissolve the status block into individual registers with
readSchedule:update so queuedRequests sends them one at a time
(max 9 bytes per response). The deviceInfo init block (8 words → 21
bytes) is left untouched.

Bump to 1.15.0+etm6.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 23:33:15 +02:00