20 lines
773 B
Markdown
20 lines
773 B
Markdown
# Amperfied - Heidelberg
|
|
|
|
Connects nymea to a Amperfied/Heidelberg wallboxes. Currently supported models are:
|
|
|
|
* Amperfeid Energy Control
|
|
* Amperfeid connect.home
|
|
|
|
# Requirements
|
|
|
|
nymea requires the use of a firmware greator or equal version 1.0.7 on the wallbox.
|
|
|
|
## Amperfeid Energy Control
|
|
The Amperfeid Energy Control is a Modbus RTU device. This means it must be connected to the nymea system using an RS485 port.
|
|
In order to allow nymea to automatically discover the wallbox on the bus, the Modbus slave ID must be in the range of 1 - 20.
|
|
If a higher slave ID number is required, the manual setup is to be used.
|
|
|
|
## Amperfied connect.home
|
|
The Amperfeid connect.home is a Modbus TCP device. This means it must be connected to the same network the nymea system is in.
|
|
|