All checks were successful
Build & Deploy docs / build-deploy (push) Successful in 3m33s
introspect.json relevé sur une box nymea 1.15.2 avec le moteur ETM 1.15.2+etm70 : 34 méthodes NymeaEnergy.* apparaissent, rangées dans la partie métier. EvDash disparaît : ce plugin n'est pas installé sur nos box. GetOptimizerProtocol (protocole 1.1) manque encore : la box porte un moteur antérieur ; il viendra au prochain relevé. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Ry3vBrJT1tHdxAaXdCWi6L
4.3 KiB
4.3 KiB
AirConditioning
Methods
AirConditioning.AddZone
ADMIN
Create a zones.
Parameters:
| Field | Type | Notes |
|---|---|---|
name |
String |
|
indoorSensors |
Uuid[] |
optional |
notifications |
Uuid[] |
optional |
outdoorSensors |
Uuid[] |
optional |
thermostats |
Uuid[] |
optional |
valves |
Uuid[] |
optional |
windowSensors |
Uuid[] |
optional |
Returns:
| Field | Type | Notes |
|---|---|---|
airConditioningError |
AirConditioningError | |
zone |
ZoneInfo | optional |
AirConditioning.GetZones
CONTROL
Get all Zones.
Parameters:
| Field | Type | Notes |
|---|---|---|
zoneId |
Uuid |
optional |
Returns:
| Field | Type | Notes |
|---|---|---|
airConditioningError |
AirConditioningError | |
zones |
ZoneInfos |
AirConditioning.RemoveZone
ADMIN
Remove a zone.
Parameters:
| Field | Type | Notes |
|---|---|---|
zoneId |
Uuid |
Returns:
| Field | Type | Notes |
|---|---|---|
airConditioningError |
AirConditioningError |
AirConditioning.SetZoneName
ADMIN
Set zone name.
Parameters:
| Field | Type | Notes |
|---|---|---|
name |
String |
|
zoneId |
Uuid |
Returns:
| Field | Type | Notes |
|---|---|---|
airConditioningError |
AirConditioningError |
AirConditioning.SetZoneSetpointOverride
CONTROL
Set zone setpoint override temperature. Parameter minutes gives the minutes until the setpoint should return to the standby/schedule.
Parameters:
| Field | Type | Notes |
|---|---|---|
mode |
SetpointOverrideMode | |
minutes |
Int |
optional |
setpointOverride |
Double |
|
zoneId |
Uuid |
Returns:
| Field | Type | Notes |
|---|---|---|
airConditioningError |
AirConditioningError |
AirConditioning.SetZoneStandbySetpoint
ADMIN
Set zone standby setpoint temperature.
Parameters:
| Field | Type | Notes |
|---|---|---|
standbySetpoint |
Double |
|
zoneId |
Uuid |
Returns:
| Field | Type | Notes |
|---|---|---|
airConditioningError |
AirConditioningError |
AirConditioning.SetZoneThings
ADMIN
Set Zone things
Parameters:
| Field | Type | Notes |
|---|---|---|
indoorSensors |
Uuid[] |
optional |
notifications |
Uuid[] |
optional |
outdoorSensors |
Uuid[] |
optional |
thermostats |
Uuid[] |
optional |
valves |
Uuid[] |
optional |
windowSensors |
Uuid[] |
optional |
zoneId |
Uuid |
Returns:
| Field | Type | Notes |
|---|---|---|
airConditioningError |
AirConditioningError |
AirConditioning.SetZoneWeekSchedule
CONTROL
Set the time schedule for a zone.
Parameters:
| Field | Type | Notes |
|---|---|---|
weekSchedule |
TemperatureWeekSchedule | |
zoneId |
Uuid |
Returns:
| Field | Type | Notes |
|---|---|---|
airConditioningError |
AirConditioningError |
Notifications
AirConditioning.ZoneAdded
Emitted whenever a zone is added
Parameters:
| Field | Type | Notes |
|---|---|---|
zone |
ZoneInfo |
AirConditioning.ZoneChanged
Emitted whenever a zone changes
Parameters:
| Field | Type | Notes |
|---|---|---|
zone |
ZoneInfo |
AirConditioning.ZoneRemoved
Emitted whenever a zone is removed
Parameters:
| Field | Type | Notes |
|---|---|---|
zoneId |
Uuid |