3 Commits

Author SHA1 Message Date
Patrick Schurig
cbfb5df23e abbterra: make ABB Terra AC addable over Modbus TCP (etm2..etm5)
Follow-up to the etm1 fixes, driven by live debugging against a real ABB
Terra AC 7 kW behind a Waveshare RS485->TCP gateway (192.168.1.132, slave 2):

- etm3: disable TCP auto-discovery (createMethods = "user" only). Discovery
  blind-scans the LAN and SIGSEGVs nymead as soon as any Modbus device answers
  :502 with an exception response. The crash is in the generated reachability
  handler (abbterramodbustcpconnection.cpp:2062 dereferences the check-reachable
  reply after it is freed); it could not be fixed from the discovery code alone.
  A gateway's slave id can't be discovered anyway, so manual add is required.
- etm2: still defer/guard AbbTerraTcpDiscovery::cleanupConnection() teardown
  (kept for correctness even though discovery is now off by default).
- etm4: setupTcpThing() never called connectDevice(), so manual setup hung until
  timeout. Start the connection when the network monitor reports the device.
- etm5: decode the serial-number and firmware register fields as BCD per ABB
  spec §5.1 (0x46 = week 46, not 70; 0x22 = 22 kW). The binary reading rejected
  real chargers ("does not match the ABB Terra AC Modbus register map").

Verified end to end: charger adds cleanly (TACW7-4-4624-S0034), states poll and
actions execute, no SIGSEGV. The underlying discovery/generated-code crash is
tracked separately.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-03 12:14:44 +02:00
Patrick Schurig
368c80688a abbterra: fix TCP discovery SEGV + restore checkReachableRegister
Two coupled fixes so the ABB Terra AC can be added over Modbus TCP:

- Restore checkReachableRegister ("serialNumber") in the register JSON.
  The libnymea-modbus 1.15 code generator *requires* it — without it the
  connection classes (abbterramodbustcpconnection.h) are never generated and
  the plugin fails to build. Reverts the false lead in b23a9a2. The register
  is valid: mbpoll confirms holding reg 16384 (uint64) responds at slave 2.

- Fix a use-after-free in AbbTerraTcpDiscovery::cleanupConnection() that
  SIGSEGV'd nymead during network discovery whenever any Modbus device on the
  LAN answered on :502 with an exception (e.g. "illegal data address"). The
  method is invoked from several of the connection's own signals; it now
  bails out on the second (re-entrant) call and disconnects the connection's
  signals before disconnectDevice(), so the teardown can no longer re-enter
  while the QModbusReply "finished" handler is still dereferencing the reply.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-03 10:48:47 +02:00
Patrick Schurig
c26b0336bd Ajout plugin ABB Terra AC (vendoring upstream experimental-silo)
- abbterra/ copié depuis nymea-plugins-modbus experimental-silo (a652793)
- paquet nymea-plugin-abbterra (nom upstream, vendoring tracé dans VENDORED.md)
- 3 paquets binaires => .install par paquet
- abbterra ajouté à FORKED_PLUGINS du mirror (exclusion upstream)
- changelog 1.15.0+etm3
2026-06-01 07:38:51 +02:00