# my-PV
NIGHTLY NYMEA
Control my-PV network enabled heating rods.
**Fabricant :** my-PV
**Plugin :** `Mypv`
#### Modèles pris en charge
| Modèle | Rôle | Transport | Ajout | Grandeurs |
| --- | --- | --- | --- | --- |
| **AC Elwa E** | heating, temperaturesensor | — | Discovery | 6 |
#### Détail par modèle
??? abstract "AC Elwa E — `elwa`"
_Réglages :_
| Clé | Libellé | Type | Plage | Défaut | Lecture seule |
| --- | --- | --- | --- | --- | --- |
| `ipAddress` | IP address | QString | — | — | non |
| `serialNumber` | Serial number | QString | — | — | non |
_Grandeurs mesurées :_
| Clé | Grandeur | Type | Unité |
| --- | --- | --- | --- |
| `connected` | Connected | bool | — |
| `power` | Power | bool | — |
| `heatingPower` | Power consumption | int | Watt |
| `temperature` | Water temperature | double | DegreeCelsius |
| `targetWaterTemperature` | Target water temperature | double | DegreeCelsius |
| `status` | Status | QString | — |