This repository has been archived on 2026-05-31. You can view files and clone it, but cannot push or open issues or pull requests.
powersync-zigbee/libnymea-zigbee/zcl/manufacturerspecific/philips/zigbeeclustermanufacturerspecificphilips.cpp
Michael Zanetti df0b7e9c63 Rafactor handling of TSNs in ZCL to allow the application using it.
This patch separates the transactionSequenceNumber used for sending from the
one received. According to the specification, the transactionSequenceNumber is
not meant to equally increase on both ends, but instead really just be a "random"
number which allows to match a reply to a request. Syncing them on both ends
has the outcome to increase the likelyhood of collisions if a device sends
a notification at the same time we send a request and thus even may wrongly
interpret that incoming command as a reply to the request. In fact, ideally TSNs for
outgoing messages would stay away as far as possible from incoming ones.

The old code additionally had the problem that it would re-use the last received
TSN for outgoing requests, given it used a post-increment when reading
m_transactionSequenceNumber after setting it to the last received TSN.

The new code will use a single static upcounting TSN for all outgoing requests
but will still allow overriding it with a custom TSN of for some reason a certain
device requires a specific TSN (apparently those exist).
It will not do anything with incoming TSNs but forward them now to the application
layer which may decide to use it match its own transactions or to deduplicate packets.

This allows fixing the issue in nymea that remote controls sometimes produce duplicate
pressed events (seen most often with the Tradfri Symfonisk) by discarding commands that
didn't increase the TSN.
2022-01-22 13:51:21 +01:00

72 lines
3.5 KiB
C++

/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
*
* Copyright 2013 - 2020, nymea GmbH
* Contact: contact@nymea.io
*
* This file is part of nymea-zigbee.
* This project including source code and documentation is protected by copyright law, and
* remains the property of nymea GmbH. All rights, including reproduction, publication,
* editing and translation, are reserved. The use of this project is subject to the terms of a
* license agreement to be concluded with nymea GmbH in accordance with the terms
* of use of nymea GmbH, available under https://nymea.io/license
*
* GNU Lesser General Public License Usage
* Alternatively, this project may be redistributed and/or modified under the terms of the GNU
* Lesser General Public License as published by the Free Software Foundation; version 3.
* this project is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY;
* without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
* See the GNU Lesser General Public License for more details.
*
* You should have received a copy of the GNU Lesser General Public License along with this project.
* If not, see <https://www.gnu.org/licenses/>.
*
* For any further details and any questions please contact us under contact@nymea.io
* or see our FAQ/Licensing Information on https://nymea.io/license/faq
*
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
#include "zigbeeclustermanufacturerspecificphilips.h"
#include "zigbeenetworkreply.h"
#include "loggingcategory.h"
#include "zigbeenetwork.h"
#include "zigbeeutils.h"
#include <QDataStream>
ZigbeeClusterManufacturerSpecificPhilips::ZigbeeClusterManufacturerSpecificPhilips(ZigbeeNetwork *network, ZigbeeNode *node, ZigbeeNodeEndpoint *endpoint, Direction direction, QObject *parent) :
ZigbeeCluster(network, node, endpoint, ZigbeeClusterLibrary::ClusterIdManufacturerSpecificPhilips, direction, parent)
{
}
void ZigbeeClusterManufacturerSpecificPhilips::processDataIndication(ZigbeeClusterLibrary::Frame frame)
{
qCDebug(dcZigbeeCluster()) << "Processing manufacturer specific (Philips) cluster frame" << m_node << m_endpoint << this << frame;
switch (m_direction) {
case Client:
qCWarning(dcZigbeeCluster()) << "Unhandled ZCL indication in" << m_node << m_endpoint << this << frame;
break;
case Server:
if (frame.header.frameControl.direction == ZigbeeClusterLibrary::DirectionServerToClient) {
Command command = static_cast<Command>(frame.header.command);
switch (command) {
case CommandButtonPress: {
QDataStream payloadStream(frame.payload);
payloadStream.setByteOrder(QDataStream::LittleEndian);
quint8 button; quint16 unknown1; quint8 unknown2; quint8 operation;
payloadStream >> button >> unknown1 >> unknown2 >> operation;
qCDebug(dcZigbeeCluster()) << "Received manufacturer specific (Philips) button press. Button:" << button << "Operation:" << operation;
emit buttonPressed(button, Operation(operation), frame.header.transactionSequenceNumber);
break;
}
default:
qCWarning(dcZigbeeCluster()) << "Unhandled ZCL indication in" << m_node << m_endpoint << this << frame;
}
} else {
qCWarning(dcZigbeeCluster()) << "Unhandled ZCL indication in" << m_node << m_endpoint << this << frame;
}
break;
}
}