Fronius: Add support for S0 meters
parent
d4d9ad698d
commit
adc2b8d0d4
|
|
@ -375,15 +375,26 @@ void IntegrationPluginFronius::refreshConnection(FroniusSolarConnection *connect
|
|||
QVariantMap dataMap = jsonDoc.toVariant().toMap().value("Body").toMap().value("Data").toMap();
|
||||
QString thingName;
|
||||
QString serialNumber;
|
||||
QString model;
|
||||
|
||||
if (dataMap.contains("Details")) {
|
||||
QVariantMap details = dataMap.value("Details").toMap();
|
||||
thingName = details.value("Manufacturer", "Fronius").toString() + " " + details.value("Model", "Smart Meter").toString();
|
||||
model = dataMap.value("Details").toMap().value("Model", "Smart Meter").toString();
|
||||
thingName = details.value("Manufacturer", "Fronius").toString() + " " + model;
|
||||
serialNumber = details.value("Serial").toString();
|
||||
} else {
|
||||
thingName = connectionThing->name() + " Meter " + meterId;
|
||||
}
|
||||
|
||||
// Note: some inverters have a S0 meter connected, which measures the load, not the grid power and also provides only the current power and no additionl information
|
||||
// Since we assume a meter on the grid root of the household, we don't update the meter here, but in the updatePowerFlow method.
|
||||
if (model.toLower().contains("s0") && !dataMap.contains("EnergyReal_WAC_Sum_Produced") && !dataMap.contains("EnergyReal_WAC_Sum_Consumed")) {
|
||||
qCDebug(dcFronius()) << "Detected weak meter on inverter (S0). Using the plant overview grid power as meter information for this one.";
|
||||
m_weakMeterConnections[connection] = true;
|
||||
} else {
|
||||
m_weakMeterConnections[connection] = false;
|
||||
}
|
||||
|
||||
ThingDescriptor descriptor(meterThingClassId, thingName, QString(), connectionThing->id());
|
||||
ParamList params;
|
||||
params.append(Param(meterThingIdParamTypeId, meterId));
|
||||
|
|
@ -529,6 +540,15 @@ void IntegrationPluginFronius::updatePowerFlow(FroniusSolarConnection *connectio
|
|||
}
|
||||
}
|
||||
|
||||
Things availableMeters = myThings().filterByParentId(parentThing->id()).filterByThingClassId(meterThingClassId);
|
||||
if (availableMeters.count() == 1 && m_weakMeterConnections.value(connection)) {
|
||||
Thing *meterThing = availableMeters.first();
|
||||
double gridPower = dataMap.value("Site").toMap().value("P_Grid").toDouble();
|
||||
meterThing->setStateValue(meterCurrentPowerStateTypeId, gridPower);
|
||||
qCDebug(dcFronius()) << "Using power flow grid power for the weak S0 meter" << gridPower << "House consumption" << dataMap.value("Site").toMap().value("P_Load").toDouble();
|
||||
}
|
||||
|
||||
|
||||
});
|
||||
}
|
||||
|
||||
|
|
@ -601,7 +621,7 @@ void IntegrationPluginFronius::updateMeters(FroniusSolarConnection *connection)
|
|||
{
|
||||
Thing *parentThing = m_froniusConnections.value(connection);
|
||||
foreach (Thing *meterThing, myThings().filterByParentId(parentThing->id()).filterByThingClassId(meterThingClassId)) {
|
||||
int meterId = meterThing->paramValue(inverterThingIdParamTypeId).toInt();
|
||||
int meterId = meterThing->paramValue(meterThingIdParamTypeId).toInt();
|
||||
|
||||
// Get the inverter realtime data
|
||||
FroniusNetworkReply *realtimeDataReply = connection->getMeterRealtimeData(meterId);
|
||||
|
|
@ -622,9 +642,29 @@ void IntegrationPluginFronius::updateMeters(FroniusSolarConnection *connection)
|
|||
return;
|
||||
}
|
||||
|
||||
|
||||
// Parse the data and update the states of our device
|
||||
QVariantMap dataMap = jsonDoc.toVariant().toMap().value("Body").toMap().value("Data").toMap();
|
||||
//qCDebug(dcFronius()) << "Meter data" << qUtf8Printable(QJsonDocument::fromVariant(dataMap).toJson(QJsonDocument::Indented));
|
||||
qCDebug(dcFronius()) << "Meter data" << qUtf8Printable(QJsonDocument::fromVariant(dataMap).toJson(QJsonDocument::Indented));
|
||||
|
||||
meterThing->setStateValue("connected", true);
|
||||
|
||||
// Note: some inverters have a S0 meter connected, which measures the load, not the grid power and also provides only the current power and no additionl information
|
||||
// Since we assume a meter on the grid root of the household, we don't update the meter here, but in the updatePowerFlow method.
|
||||
QString model;
|
||||
if (dataMap.contains("Details")) {
|
||||
model = dataMap.value("Details").toMap().value("Model", "Smart Meter").toString();
|
||||
}
|
||||
|
||||
// Note: maybe we find a better way to detect a weak meter, for now, we only knwo it does not provide any additional informaiton and has a S0 in the name
|
||||
if (model.toLower().contains("s0") && !dataMap.contains("EnergyReal_WAC_Sum_Produced") && !dataMap.contains("EnergyReal_WAC_Sum_Consumed")) {
|
||||
qCDebug(dcFronius()) << "Ignoring this meter since there are not enought information available (S0). Using the plant overview grid power as meter information.";
|
||||
m_weakMeterConnections[connection] = true;
|
||||
return;
|
||||
} else {
|
||||
m_weakMeterConnections[connection] = false;
|
||||
}
|
||||
|
||||
|
||||
// Power
|
||||
if (dataMap.contains("PowerReal_P_Sum")) {
|
||||
|
|
@ -682,8 +722,6 @@ void IntegrationPluginFronius::updateMeters(FroniusSolarConnection *connection)
|
|||
if (dataMap.contains("Frequency_Phase_Average")) {
|
||||
meterThing->setStateValue(meterFrequencyStateTypeId, dataMap.value("Frequency_Phase_Average").toDouble());
|
||||
}
|
||||
|
||||
meterThing->setStateValue("connected", true);
|
||||
});
|
||||
}
|
||||
}
|
||||
|
|
@ -772,3 +810,4 @@ void IntegrationPluginFronius::markStorageAsDisconnected(Thing *thing)
|
|||
thing->setStateValue("chargingState", "idle");
|
||||
// Note: do not reset the energy counters since they are always counting up until reset on the device
|
||||
}
|
||||
|
||||
|
|
|
|||
|
|
@ -59,6 +59,7 @@ private:
|
|||
|
||||
QHash<FroniusSolarConnection *, Thing *> m_froniusConnections;
|
||||
QHash<Thing *, NetworkDeviceMonitor *> m_monitors;
|
||||
QHash<FroniusSolarConnection *, bool> m_weakMeterConnections;
|
||||
|
||||
void refreshConnection(FroniusSolarConnection *connection);
|
||||
|
||||
|
|
|
|||
Loading…