This repository has been archived on 2026-05-31. You can view files and clone it, but cannot push or open issues or pull requests.
Hermann Detz e202b328b7 Removed faulty functionality.
Write access to target temperatures for air and water, as well as
humidity sensor were removed.

Code clean-up + comments added.
2021-06-27 17:24:38 +02:00

186 lines
8.0 KiB
C++

/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
*
* Copyright 2013 - 2020, nymea GmbH
* Contact: contact@nymea.io
*
* This file is part of nymea.
* This project including source code and documentation is protected by
* copyright law, and remains the property of nymea GmbH. All rights, including
* reproduction, publication, editing and translation, are reserved. The use of
* this project is subject to the terms of a license agreement to be concluded
* with nymea GmbH in accordance with the terms of use of nymea GmbH, available
* under https://nymea.io/license
*
* GNU Lesser General Public License Usage
* Alternatively, this project may be redistributed and/or modified under the
* terms of the GNU Lesser General Public License as published by the Free
* Software Foundation; version 3. This project is distributed in the hope that
* it will be useful, but WITHOUT ANY WARRANTY; without even the implied
* warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* Lesser General Public License for more details.
*
* You should have received a copy of the GNU Lesser General Public License
* along with this project. If not, see <https://www.gnu.org/licenses/>.
*
* For any further details and any questions please contact us under
* contact@nymea.io or see our FAQ/Licensing Information on
* https://nymea.io/license/faq
*
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
#ifndef IDM_H
#define IDM_H
#include <QObject>
#include "../modbus/modbustcpmaster.h"
#include "idminfo.h"
/*
* Functionality:
* The current version allows read access to selected
* modbus registers:
* + Room temperature (HK A)
* + Water temperature
* + Outside air temperature
* + Target room temperature eco mode (HK A)
* + Target water temperature
* + Current power consumption
* + Operation mode
* + Error
*
* At present there is no write access for target
* room temperature and target water temperature. These
* result in an "invalid data access" error from the
* device.
*/
/* Note: It would be desirable to read the modbus registers
* of the Idm heat pump in groups to minimize the number
* of read requests. However, a maximum of 6 registers
* can be read simultaneously. With the given set of
* addresses it is not possible to reasonably group the
* registers, therefore they are read individually.
*/
class Idm : public QObject
{
Q_OBJECT
public:
/** Constructor */
explicit Idm(const QHostAddress &address, QObject *parent = nullptr);
/** Destructor */
~Idm();
private:
/** Modbus Unit ID of Idm device */
static const quint16 ModbusUnitID = 1;
enum IscModus {
KeineAbwarme = 0,
Heizung = 1,
Warmwasser = 4,
Warmequelle = 8,
};
/** System operation modes according to manual p. 13 */
enum IdmSysMode {
IdmSysModeStandby = 0,
IdmSysModeAutomatic = 1,
IdmSysModeAway = 2,
IdmSysModeOnlyHotwater = 4,
IdmSysModeOnlyRoomHeating = 5
};
/** Heat pump operation modes according to manual p. 14 */
enum IdmHeatPumpMode {
IdmHeatPumpModeOff = 0,
IdmHeatPumpModeHeating = 1,
IdmHeatPumpModeCooling = 2,
IdmHeatPumpModeHotWater = 4,
IdmHeatPumpModeDefrost = 8
};
/** The following modbus addresses are according to the manual
* Modbus TCP Navigatorregelung 2.0 pages 13-31.
* Comments at the end of each line give their original name
* in the German manual. */
enum RegisterList {
OutsideTemperature = 1000, // Außentemperatur (B31)
MeanOutsideTemperature = 1002, // Gemittelte Außentemperature
CurrentFaultNumber = 1004, // Aktuelle Störungsnummer
OperationModeSystem = 1005, // Betriebsart System
SmartGridStatus = 1006, // Smart Grid Status
HeatStorageTemperature = 1008, // Wärmespeichertemperatur (B38)
ColdStorageTemperature = 1010, // Kältespeichertemperatur (B40)
DrinkingWaterHeaterTempBottom = 1012, // Trinkwassererwärmertmp. unten (B41)
DrinkingWaterHeaterTempTop = 1014, // Trinkwassererwärmertmp. oben (B48)
HotWaterTapTemperature = 1030, // Warmwasserzapftemperatur (B42)
TargetHotWaterTemperature = 1032, // Warmwasser-Solltemperatur
HeatPumpOperatingMode = 1090, // Betriebsart Wärmepumpe
SummationFaultHeatPump = 1099, // Summenstörung Wärepumpe
RoomTemperatureHKA = 1364, // Heizkreis A Raumtemperature (B61)
HumiditySensor = 1392, // Feuchtesensor
RoomTemperatureTargetHeatingHKA = 1401, // Raumsolltemperatur Heizen Normal HK A
RoomTemperatureTargetHeatingEcoHKA = 1415, // Raumsolltemperatur Heizen Eco HK A
ExternalOutsideTemperature = 1690, // Externe Außentemperatur
ExternalHumidity = 1692, // Externe Feuchte
ExternalRequestTemperatureHeating = 1694, // Externe Anforderungstemperatur Heizen
ExternalRequestTemperatureCooling = 1695, // Externe Anforderungstemperatur Kühlen
HeatingRequirement = 1710, // Anforderung Heizen
CoolingRequirement = 1711, // Anforderung Kühlen
HotWaterChargingRequirement = 1712, // Anforderung Warmwasserladung
HeatQuantityHeating = 1750, // Wärmemenge Heizen
HeatQuantityCooling = 1752, // Wärmemenge Kühlen
HeatQuantityHotWater = 1754, // Wärmemenge Warmwasser
HeatQuantityDefrosting = 1756, // Wärmemenge Abtauung
HeatQuantityPassiveCooling = 1758, // Wärmemenge Passive Kühlung,
HeatQuantityPhotovolatics = 1760, // Wärmemenge Solar
HeatQuantityHeatingElemetn = 1762, // Wärmemenge Elektroheizeinsatz,
CurrentPower = 1790, // Momentanleistung
CurrentPowerSolar = 1792, // MomentanleistungSolar
SolarCollectorTemperature = 1850, // SolarKollektortemperatur (B73)
SolarCollectorReturnTemperature = 1852, // SolarKollektorruecklauftemperatur (B75)
SolarChargeTemperature = 1854, // SolarLadetemperatur (B74)
SolarOperatingMode = 1856, // Betriebsart Solar
ISCMode = 1875, // ISCModus
AcknowledgeFaultMessages = 1999, // Störmeldungen quittieren
TargetRoomTemperatureZ1R1 = 2004, // Zonenmodul 1 Raumsolltemperatur Raum 1
CurrentPhotovoltaicsSurplus = 74, // Aktueller PV-Überschuss
CurrentPhotovoltaicsProduction = 78, // Aktueller PV Produktion
CurrentPowerConsumptionHeatPump = 4122, // Aktuelle Leistungsaufnahme Wärmepumpe
};
/* Note: This class only requires one IP address and one
* TCP Modbus connection. Multiple devices are managed
* within the IntegrationPluginIdm class. */
QHostAddress m_hostAddress;
/** Pointer to ModbusTCPMaster object, responseible for low-level communicaiton */
ModbusTCPMaster *m_modbusMaster = nullptr;
/** This structure is allocated within onRequestStatus and filled
* by the receivedStatusGroupx functions */
IdmInfo *m_info = nullptr;
/** Converts a system operation mode code to a string (according to manual p. 13) */
QString systemOperationModeToString(IdmSysMode mode);
/** Converts a heat pump operation mode code to a string (according to manual p. 14) */
QString heatPumpOperationModeToString(IdmHeatPumpMode mode);
signals:
void statusUpdated(IdmInfo *info);
void targetRoomTemperatureChanged();
public slots:
void onModbusError();
void onRequestStatus();
void onReceivedHoldingRegister(int slaveAddress, int modbusRegister, const QVector<quint16> &value);
};