245 lines
11 KiB
JSON
245 lines
11 KiB
JSON
{
|
|
"name": "EnergyMeters",
|
|
"displayName": "EnergyMeters",
|
|
"id": "56e95111-fb6b-4f63-9a0a-a5ee001e89ed",
|
|
"paramTypes":[
|
|
{
|
|
"id": "eaa84c3c-06b8-4642-a40b-c2efbe6aae66",
|
|
"name": "updateInterval",
|
|
"displayName": "Update interval",
|
|
"type": "uint",
|
|
"unit": "MilliSeconds",
|
|
"defaultValue": 300,
|
|
"minValue": 200
|
|
}
|
|
],
|
|
"vendors": [
|
|
{
|
|
"name": "ineproMetering",
|
|
"displayName": "inepro Metering",
|
|
"id": "64f4df0f-18ce-409c-bf32-84a086c691ca",
|
|
"thingClasses": [
|
|
{
|
|
"name": "pro380",
|
|
"displayName": "PRO380-Mod",
|
|
"id": "d7c6440b-54f9-4cc0-a96b-9bb7304b3e77",
|
|
"createMethods": ["discovery"],
|
|
"interfaces": ["extendedsmartmeterconsumer"],
|
|
"discoveryParamTypes": [
|
|
{
|
|
"id": "a29f37f6-b344-4628-8ab4-8f4c18fada4a",
|
|
"name": "slaveAddress",
|
|
"displayName": "Slave address",
|
|
"type": "int",
|
|
"defaultValue": 1
|
|
}
|
|
],
|
|
"paramTypes": [
|
|
{
|
|
"id": "c75b2c31-6ec3-49ab-8c8f-5231d0a7e941",
|
|
"name": "slaveAddress",
|
|
"displayName": "Modbus slave address",
|
|
"type": "int",
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"id": "6cdbec8c-21b9-42dc-b1ab-8901ac609482",
|
|
"name": "modbusMasterUuid",
|
|
"displayName": "Modbus RTU master",
|
|
"type": "QUuid",
|
|
"defaultValue": "",
|
|
"readOnly": true
|
|
}
|
|
],
|
|
"stateTypes": [
|
|
{
|
|
"id": "7f9bc504-0882-4b86-83b1-42fa345acfd9",
|
|
"name": "connected",
|
|
"displayName": "Connected",
|
|
"displayNameEvent": "Connected changed",
|
|
"type": "bool",
|
|
"cached": false,
|
|
"defaultValue": false
|
|
},
|
|
{
|
|
"id": "04dba21a-7447-46b9-b9ae-095e5769e511",
|
|
"name": "voltage",
|
|
"displayName": "Voltage",
|
|
"displayNameEvent": "Voltage changed",
|
|
"type": "double",
|
|
"unit": "Volt",
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"id": "1e077a3b-2dab-4ec4-ae96-ab49a564fe31",
|
|
"name": "current",
|
|
"displayName": "Current",
|
|
"displayNameEvent": "Current changed",
|
|
"type": "double",
|
|
"unit": "Ampere",
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"id": "464eff60-11c2-46b7-98f5-1aa8172e5a2d",
|
|
"name": "currentPower",
|
|
"displayName": "Active power",
|
|
"displayNameEvent": "Active power changed",
|
|
"type": "double",
|
|
"unit": "Watt",
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"id": "cdb34487-3d9b-492a-8c33-802f32a2e90e",
|
|
"name": "powerFactor",
|
|
"displayName": "Power factor",
|
|
"displayNameEvent": "Power factor changed",
|
|
"type": "double",
|
|
"defaultValue": 0.00
|
|
},
|
|
{
|
|
"id": "bb6fd00c-3bbb-4977-bb8a-96787bb6f5c5",
|
|
"name": "frequency",
|
|
"displayName": "Frequency",
|
|
"displayNameEvent": "Frequency changed",
|
|
"type": "double",
|
|
"unit": "Hertz",
|
|
"defaultValue": 0.00
|
|
},
|
|
{
|
|
"id": "f18fd596-b47f-44be-a0f0-6ca44369ebf5",
|
|
"name": "totalEnergyConsumed",
|
|
"displayName": "Total energy consumed",
|
|
"displayNameEvent": "Total energy consumed changed",
|
|
"type": "double",
|
|
"unit": "KiloWattHour",
|
|
"defaultValue": 0.00
|
|
},
|
|
{
|
|
"id": "112911c9-14e0-4c83-ac92-f2ceb3bdecdf",
|
|
"name": "totalEnergyProduced",
|
|
"displayName": "Total energy produced",
|
|
"displayNameEvent": "Total energy produced changed",
|
|
"type": "double",
|
|
"unit": "KiloWattHour",
|
|
"defaultValue": 0.00
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"name": "bgetech",
|
|
"displayName": "B+G e-tech",
|
|
"id": "215035fe-95e8-43d8-a52e-0a31b787d902",
|
|
"thingClasses": [
|
|
{
|
|
"name": "sdm630",
|
|
"displayName": "SDM630Modbus",
|
|
"id": "f37597bb-35fe-48f2-9617-343dd54c0903",
|
|
"createMethods": ["discovery"],
|
|
"interfaces": ["extendedsmartmeterconsumer"],
|
|
"discoveryParamTypes": [
|
|
{
|
|
"id": "6ab43559-53ec-47ba-b8a0-8d3b7f8d90c2",
|
|
"name": "slaveAddress",
|
|
"displayName": "Slave address",
|
|
"type": "int",
|
|
"defaultValue": 1
|
|
}
|
|
],
|
|
"paramTypes": [
|
|
{
|
|
"id": "ac77ea98-b006-486e-a3e8-b30a483f26c1",
|
|
"name": "slaveAddress",
|
|
"displayName": "Modbus slave address",
|
|
"type": "int",
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"id": "d90e9292-d03c-4f2a-957e-5d965018c9c9",
|
|
"name": "modbusMasterUuid",
|
|
"displayName": "Modbus RTU master",
|
|
"type": "QUuid",
|
|
"defaultValue": "",
|
|
"readOnly": true
|
|
}
|
|
],
|
|
"stateTypes": [
|
|
{
|
|
"id": "8050bd0b-1dad-4a7e-b632-c71ead3c9f8b",
|
|
"name": "connected",
|
|
"displayName": "Connected",
|
|
"displayNameEvent": "Connected changed",
|
|
"type": "bool",
|
|
"cached": false,
|
|
"defaultValue": false
|
|
},
|
|
{
|
|
"id": "4636ec5c-fcb9-45b7-ad68-2818cb615ce1",
|
|
"name": "voltage",
|
|
"displayName": "Voltage",
|
|
"displayNameEvent": "Voltage changed",
|
|
"type": "double",
|
|
"unit": "Volt",
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"id": "96bc65ce-5bde-4a69-9ebf-711d65c6501c",
|
|
"name": "current",
|
|
"displayName": "Current",
|
|
"displayNameEvent": "Current changed",
|
|
"type": "double",
|
|
"unit": "Ampere",
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"id": "c824e97b-a6d1-4030-9d7a-00af6fb8e1c3",
|
|
"name": "currentPower",
|
|
"displayName": "Active power",
|
|
"displayNameEvent": "Active power changed",
|
|
"type": "double",
|
|
"unit": "Watt",
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"id": "31b9032f-f994-472b-94bd-44f9fb094801",
|
|
"name": "powerFactor",
|
|
"displayName": "Power factor",
|
|
"displayNameEvent": "Power factor changed",
|
|
"type": "double",
|
|
"defaultValue": 0.00
|
|
},
|
|
{
|
|
"id": "ab24f26c-dc15-4ec3-8d76-06a48285440b",
|
|
"name": "frequency",
|
|
"displayName": "Frequency",
|
|
"displayNameEvent": "Frequency changed",
|
|
"type": "double",
|
|
"unit": "Hertz",
|
|
"defaultValue": 0.00
|
|
},
|
|
{
|
|
"id": "98d858a8-22e8-4262-b5c7-25bb027942ad",
|
|
"name": "totalEnergyConsumed",
|
|
"displayName": "Total energy consumed",
|
|
"displayNameEvent": "Total energy consumed changed",
|
|
"type": "double",
|
|
"unit": "KiloWattHour",
|
|
"defaultValue": 0.00
|
|
},
|
|
{
|
|
"id": "e469b3ff-a4c2-42da-af35-ccafaef214af",
|
|
"name": "totalEnergyProduced",
|
|
"displayName": "Total energy produced",
|
|
"displayNameEvent": "Total energy produced changed",
|
|
"type": "double",
|
|
"unit": "KiloWattHour",
|
|
"defaultValue": 0.00
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|