168 lines
5.8 KiB
C++
168 lines
5.8 KiB
C++
/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
|
|
*
|
|
* Copyright 2013 - 2020, nymea GmbH
|
|
* Contact: contact@nymea.io
|
|
*
|
|
* This file is part of nymea.
|
|
* This project including source code and documentation is protected by
|
|
* copyright law, and remains the property of nymea GmbH. All rights, including
|
|
* reproduction, publication, editing and translation, are reserved. The use of
|
|
* this project is subject to the terms of a license agreement to be concluded
|
|
* with nymea GmbH in accordance with the terms of use of nymea GmbH, available
|
|
* under https://nymea.io/license
|
|
*
|
|
* GNU Lesser General Public License Usage
|
|
* Alternatively, this project may be redistributed and/or modified under the
|
|
* terms of the GNU Lesser General Public License as published by the Free
|
|
* Software Foundation; version 3. This project is distributed in the hope that
|
|
* it will be useful, but WITHOUT ANY WARRANTY; without even the implied
|
|
* warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
|
* Lesser General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU Lesser General Public License
|
|
* along with this project. If not, see <https://www.gnu.org/licenses/>.
|
|
*
|
|
* For any further details and any questions please contact us under
|
|
* contact@nymea.io or see our FAQ/Licensing Information on
|
|
* https://nymea.io/license/faq
|
|
*
|
|
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
|
|
|
|
#ifndef SUNSPECMETER_H
|
|
#define SUNSPECMETER_H
|
|
|
|
#include <QObject>
|
|
#include "sunspec.h"
|
|
|
|
class SunSpecMeter : public QObject
|
|
{
|
|
Q_OBJECT
|
|
public:
|
|
|
|
enum MeterEventFlags {
|
|
MeterEventPowerFailure = 2,
|
|
MeterEventUnderVoltage,
|
|
MeterEventLowPF,
|
|
MeterEventOverCurrent,
|
|
MeterEventOverVoltage,
|
|
MeterEventMissing_Sensor,
|
|
MeterEventReserved1,
|
|
MeterEventReserved2,
|
|
MeterEventReserved3,
|
|
MeterEventReserved4,
|
|
MeterEventReserved5,
|
|
MeterEventReserved6,
|
|
MeterEventReserved7,
|
|
MeterEventReserved8,
|
|
MeterEventOEM01,
|
|
MeterEventOEM02,
|
|
MeterEventOEM03,
|
|
MeterEventOEM04,
|
|
MeterEventOEM05,
|
|
MeterEventOEM06,
|
|
MeterEventOEM07,
|
|
MeterEventOEM08,
|
|
MeterEventOEM09,
|
|
MeterEventOEM10,
|
|
MeterEventOEM11,
|
|
MeterEventOEM12,
|
|
MeterEventOEM13,
|
|
MeterEventOEM14,
|
|
MeterEventOEM15
|
|
};
|
|
|
|
//Model 201 = Single phase meter SF
|
|
//Model 202 = Split phase meter SF
|
|
//Model 203 = Three phase meter SF
|
|
//Note: For example single phase inverters, Phase B current is optional then.
|
|
enum Model20X {
|
|
Model20XTotalAcCurrent = 0,
|
|
Model20XPhaseACurrent = 1,
|
|
Model20XPhaseBCurrent = 2,
|
|
Model20XPhaseCCurrent = 3,
|
|
Model20XCurrentScaleFactor = 4,
|
|
Model20XVoltageLN = 5,
|
|
Model20XPhaseVoltageAN = 6,
|
|
Model20XPhaseVoltageBN = 7,
|
|
Model20XPhaseVoltageCN = 8,
|
|
Model20XVoltageLL = 9,
|
|
Model20XPhaseVoltageAB = 10,
|
|
Model20XPhaseVoltageBC = 11,
|
|
Model20XPhaseVoltageCA = 12,
|
|
Model20XVoltageScaleFactor = 13,
|
|
Model20XFrequency = 14,
|
|
Model20XFrequencyScaleFactor = 15,
|
|
Model20XTotalRealPower = 16,
|
|
Model20XRealPowerScaleFactor = 20,
|
|
Model20XTotalRealEnergyExported = 36,
|
|
Model20XTotalRealEnergyImported = 44,
|
|
Model20XRealEnergyScaleFactor = 52,
|
|
Model20XMeterEventFlags = 103
|
|
};
|
|
|
|
//Model 211 = Single phase meter float
|
|
//Model 212 = Split phase meter float
|
|
//Model 213 = Three phase meter float
|
|
enum Model21X {
|
|
Model21XTotalAcCurrent = 0,
|
|
Model21XPhaseACurrent = 2,
|
|
Model21XPhaseBCurrent = 4,
|
|
Model21XPhaseCCurrent = 6,
|
|
Model21XVoltageLN = 8,
|
|
Model21XPhaseVoltageAN = 10,
|
|
Model21XPhaseVoltageBN = 12,
|
|
Model21XPhaseVoltageCN = 14,
|
|
Model21XVoltageLL = 16,
|
|
Model21XPhaseVoltageAB = 18,
|
|
Model21XPhaseVoltageBC = 20,
|
|
Model21XPhaseVoltageCA = 22,
|
|
Model21XFrequency = 24,
|
|
Model21XTotalRealPower = 26,
|
|
Model21XTotalRealEnergyExported = 58,
|
|
Model21XTotalRealEnergyImported = 66,
|
|
Model21XMeterEventFlags = 122
|
|
};
|
|
|
|
struct MeterData {
|
|
double totalAcCurrent; // [A]
|
|
double phaseACurrent; // [A]
|
|
double phaseBCurrent; // [A]
|
|
double phaseCCurrent; // [A]
|
|
double voltageLN; // [V]
|
|
double phaseVoltageAN; // [V]
|
|
double phaseVoltageBN; // [V]
|
|
double phaseVoltageCN; // [V]
|
|
double voltageLL; // [V]
|
|
double phaseVoltageAB; // [V]
|
|
double phaseVoltageBC; // [V]
|
|
double phaseVoltageCA; // [V]
|
|
double frequency; // [Hz]
|
|
double totalRealPower; // [W]
|
|
double totalRealEnergyExported; // [kWh]
|
|
double totalRealEnergyImported; // [kWh]
|
|
quint32 meterEventFlags; // MeterEventFlags
|
|
};
|
|
|
|
SunSpecMeter(SunSpec *sunspec, SunSpec::ModelId modelId, int modbusAddress);
|
|
SunSpec::ModelId modelId();
|
|
void init();
|
|
void getMeterModelHeader();
|
|
void getMeterModelDataBlock();
|
|
|
|
private:
|
|
SunSpec *m_connection = nullptr;
|
|
SunSpec::ModelId m_id = SunSpec::ModelIdDeltaConnectThreePhaseMeter;
|
|
uint m_modelLength = 0;
|
|
uint m_modelModbusStartRegister = 40000;
|
|
bool m_initFinishedSuccess = false;
|
|
|
|
private slots:
|
|
void onModelDataBlockReceived(SunSpec::ModelId modelId, uint length, QVector<quint16> data);
|
|
|
|
signals:
|
|
void initFinished(bool success);
|
|
void meterDataReceived(const MeterData &data);
|
|
};
|
|
|
|
#endif // SUNSPECMETER_H
|