<sunSpecModels v="1">
<!-- 502: panel module integer -->
<model id="502" len="28" name="solar_module">
<block len="28">
<point id="A_SF" offset="0" type="sunssf" />
<point id="V_SF" offset="1" type="sunssf" />
<point id="W_SF" offset="2" type="sunssf" />
<point id="Wh_SF" offset="3" type="sunssf" />
<point id="Stat" offset="4" type="enum16" mandatory="true">
<symbol id="OFF">1</symbol>
<symbol id="SLEEPING">2</symbol>
<symbol id="STARTING">3</symbol>
<symbol id="MPPT">4</symbol>
<symbol id="THROTTLED">5</symbol>
<symbol id="SHUTTING_DOWN">6</symbol>
<symbol id="FAULT">7</symbol>
<symbol id="STANDBY">8</symbol>
<symbol id="TEST">9</symbol>
<symbol id="OTHER">10</symbol>
</point>
<point id="StatVend" offset="5" type="enum16" />
<point id="Evt" offset="6" type="bitfield32" mandatory="true">
<symbol id="GROUND_FAULT">0</symbol>
<symbol id="INPUT_OVER_VOLTAGE">1</symbol>
<symbol id="RESERVED_2">2</symbol>
<symbol id="DC_DISCONNECT">3</symbol>
<symbol id="RESERVED_4">4</symbol>
<symbol id="RESERVED_5">5</symbol>
<symbol id="MANUAL_SHUTDOWN">6</symbol>
<symbol id="OVER_TEMPERATURE">7</symbol>
<symbol id="RESERVED_8">8</symbol>
<symbol id="RESERVED_9">9</symbol>
<symbol id="RESERVED_10">10</symbol>
<symbol id="RESERVED_11">11</symbol>
<symbol id="BLOWN_FUSE">12</symbol>
<symbol id="UNDER_TEMPERATURE">13</symbol>
<symbol id="MEMORY_LOSS">14</symbol>
<symbol id="ARC_DETECTION">15</symbol>
<symbol id="THEFT_DETECTION">16</symbol>
<symbol id="OUTPUT_OVER_CURRENT">17</symbol>
<symbol id="OUTPUT_OVER_VOLTAGE">18</symbol>
<symbol id="OUTPUT_UNDER_VOLTAGE">19</symbol>
<symbol id="TEST_FAILED">20</symbol>
</point>
<point id="EvtVend" offset="8" type="bitfield32" />
<point id="Ctl" offset="10" type="enum16" access="rw" />
<point id="CtlVend" offset="11" type="enum32" access="rw" />
<point id="CtlVal" offset="13" type="int32" access="rw" />
<point id="Tms" offset="15" type="uint32" units="Secs" />
<point id="OutA" offset="17" type="int16" sf="A_SF" units="A" />
<point id="OutV" offset="18" type="int16" sf="V_SF" units="V" />
<point id="OutWh" offset="19" type="acc32" sf="Wh_SF" units="Wh" />
<point id="OutPw" offset="21" type="int16" sf="W_SF" units="W" />
<point id="Tmp" offset="22" type="int16" units="C" />
<point id="InA" offset="23" type="int16" sf="A_SF" units="A" />
<point id="InV" offset="24" type="int16" sf="V_SF" units="V" />
<point id="InWh" offset="25" type="acc32" sf="Wh_SF" units="Wh" />
<point id="InW" offset="27" type="int16" sf="W_SF" units="W" />
</block>
</model>
<strings id="502" locale="en">
<model>
<label>Solar Module</label>
<description>A solar module model supporting DC-DC converter</description>
<notes>Integer</notes>
</model>
<point id="Stat">
<label>Status</label>
<description>Enumerated value. Module Status Code</description>
<notes></notes>
<symbol id="OFF">
<label>Off</label>
<description>Module is in the OFF state</description>
<notes></notes>
</symbol>
<symbol id="SLEEPING">
<label>SLEEPING</label>
<description>Sleeping (auto-shutdown) or panel is at low/safe output power/voltage</description>
<notes></notes>
</symbol>
<symbol id="STARTING">
<label>STARTING</label>
<description>Starting up or ON but not producing power; panel might have high voltage but is not producing power</description>
<notes></notes>
</symbol>
<symbol id="MPPT">
<label>MPPT</label>
<description>Tracking MPPT power point</description>
<notes></notes>
</symbol>
<symbol id="THROTTLED">
<label>THROTTLED</label>
<description>Forced power reduction / power de-rating</description>
<notes></notes>
</symbol>
<symbol id="SHUTTING_DOWN">
<label>SHUTTING_DOWN</label>
<description>Shutting down</description>
<notes></notes>
</symbol>
<symbol id="FAULT">
<label>FAULT</label>
<description>One or more faults exist</description>
<notes></notes>
</symbol>
<symbol id="STANDBY">
<label>STANDBY</label>
<description>Standby (service or unit) - unlike SLEEPING in this mode the module might be at a high (unsafe) output voltage or power</description>
<notes></notes>
</symbol>
<symbol id="TEST">
<label>TEST</label>
<description>Test mode</description>
<notes></notes>
</symbol>
<symbol id="OTHER">
<label>OTHER</label>
<description>As defined in vendor specific status</description>
<notes></notes>
</symbol>
</point>
<point id="StatVend">
<label>Vendor Status</label>
<description>Module Vendor Status Code</description>
<notes></notes>
</point>
<point id="Evt">
<label>Events</label>
<description>Bitmask value. Module Event Flags</description>
<notes></notes>
<symbol id="GROUND_FAULT">
<label>Ground Fault</label>
<description>Ground Fault</description>
<notes></notes>
</symbol>
<symbol id="INPUT_OVER_VOLTAGE">
<label>Over Voltage</label>
<description>DC input over-voltage</description>
<notes></notes>
</symbol>
<symbol id="RESERVED">
<label>Reserved</label>
<description>Reserved</description>
<notes>Reserved for u-inverter compatibility</notes>
</symbol>
<symbol id="DC_DISCONNECT">
<label>Disconnect</label>
<description>DC disconnect open</description>
<notes></notes>
</symbol>
<symbol id="RESERVED">
<label>Reserved</label>
<description>Reserved</description>
<notes>Reserved for u-inverter compatibility</notes>
</symbol>
<symbol id="RESERVED">
<label>Reserved</label>
<description>Reserved</description>
<notes>Reserved for u-inverter compatibility</notes>
</symbol>
<symbol id="MANUAL_SHUTDOWN">
<label>Manual shutdown</label>
<description>Manual shutdown</description>
<notes></notes>
</symbol>
<symbol id="OVER_TEMPERATURE">
<label>Over Temperature</label>
<description>Over Temperature</description>
<notes></notes>
</symbol>
<symbol id="RESERVED">
<label>Reserved</label>
<description>Reserved</description>
<notes>Reserved for u-inverter compatibility</notes>
</symbol>
<symbol id="RESERVED">
<label>Reserved</label>
<description>Reserved</description>
<notes>Reserved for u-inverter compatibility</notes>
</symbol>
<symbol id="RESERVED">
<label>Reserved</label>
<description>Reserved</description>
<notes>Reserved for u-inverter compatibility</notes>
</symbol>
<symbol id="RESERVED">
<label>Reserved</label>
<description>Reserved</description>
<notes>Reserved for u-inverter compatibility</notes>
</symbol>
<symbol id="BLOWN_FUSE">
<label>Blown Fuse</label>
<description>Input fuse is blown</description>
<notes></notes>
</symbol>
<symbol id="UNDER_TEMPERATURE">
<label>Under Temperature</label>
<description>Under Temperature</description>
<notes></notes>
</symbol>
<symbol id="MEMORY_LOSS">
<label>Memory Loss</label>
<description>Generic Memory or Communication Error</description>
<notes></notes>
</symbol>
<symbol id="ARC_DETECTION">
<label>Arc Detection</label>
<description>Arc Detection</description>
<notes></notes>
</symbol>
<symbol id="THEFT_DETECTION">
<label>Theft Detection</label>
<description>Theft Detection</description>
<notes></notes>
</symbol>
<symbol id="OUTPUT_OVER_CURRENT">
<label>Over Current</label>
<description>Output Over Current</description>
<notes></notes>
</symbol>
<symbol id="OUTPUT_OVER_VOLTAGE">
<label>Output Over Voltage</label>
<description>DC Output Over Voltage</description>
<notes></notes>
</symbol>
<symbol id="OUTPUT_UNDER_VOLTAGE">
<label>Output Under Voltage</label>
<description>DC Output Under Voltage</description>
<notes></notes>
</symbol>
<symbol id="TEST_FAILED">
<label>Test Failed</label>
<description>Last Self Test failed; see vendor event for details</description>
<notes></notes>
</symbol>
</point>
<point id="EvtVend">
<label>Vendor Module Event Flags</label>
<description>Vendor specific flags</description>
<notes></notes>
</point>
<point id="A_SF">
<label></label>
<description>Current scale factor</description>
<notes></notes>
</point>
<point id="V_SF">
<label></label>
<description>Voltage scale factor</description>
<notes></notes>
</point>
<point id="W_SF">
<label></label>
<description>Power scale factor</description>
<notes></notes>
</point>
<point id="Wh_SF">
<label></label>
<description>Energy scale factor</description>
<notes></notes>
</point>
<point id="Ctl">
<label>Control</label>
<description>Module Control</description>
<notes></notes>
</point>
<point id="CtlVend">
<label>Vendor Control</label>
<description>Vendor Module Control</description>
<notes></notes>
</point>
<point id="CtlVal">
<label>Control Value</label>
<description>Module Control Value</description>
<notes></notes>
</point>
<point id="Tms">
<label>Timestamp</label>
<description>Time in seconds since 2000 epoch</description>
<notes></notes>
</point>
<point id="OutA">
<label>Output Current</label>
<description>Output Current</description>
<notes></notes>
</point>
<point id="OutV">
<label>Output Voltage</label>
<description>Output Voltage</description>
<notes></notes>
</point>
<point id="OutWh">
<label>Output Energy</label>
<description>Output Energy</description>
<notes></notes>
</point>
<point id="OutPw">
<label>Output Power</label>
<description>Output Power</description>
<notes></notes>
</point>
<point id="Tmp">
<label>Temp</label>
<description>Module Temperature</description>
<notes></notes>
</point>
<point id="InA">
<label>Input Current</label>
<description>Input Current</description>
<notes></notes>
</point>
<point id="InV">
<label>Input Voltage</label>
<description>Input Voltage</description>
<notes></notes>
</point>
<point id="InWh">
<label>Input Energy</label>
<description>Input Energy</description>
<notes></notes>
</point>
<point id="InW">
<label>Input Power</label>
<description>Input Power</description>
<notes></notes>
</point>
</strings>