// SPDX-License-Identifier: GPL-3.0-or-later
|
|
|
|
/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
|
|
*
|
|
* Copyright (C) 2013 - 2024, nymea GmbH
|
|
* Copyright (C) 2024 - 2025, chargebyte austria GmbH
|
|
*
|
|
* This file is part of nymea-plugins-modbus.
|
|
*
|
|
* nymea-plugins-modbus is free software: you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation, either version 3 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* nymea-plugins-modbus is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with nymea-plugins-modbus. If not, see <https://www.gnu.org/licenses/>.
|
|
*
|
|
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
|
|
|
|
#include "huaweismartlogger.h"
|
|
|
|
Q_DECLARE_LOGGING_CATEGORY(dcHuaweiSmartLoggerModbusTcpConnection)
|
|
|
|
HuaweiSmartLogger::HuaweiSmartLogger(const QHostAddress &hostAddress, uint port, quint16 meterSlaveId, QObject *parent)
|
|
: HuaweiSmartLoggerModbusTcpConnection{hostAddress, port, 0, parent},
|
|
m_meterSlaveId{meterSlaveId}
|
|
{
|
|
// Note: the smart logger only responds to requests on slave ID 0 (broadcast), the meter itself can be
|
|
// accessed using the connected modbus RTU slave ID, therefore we need to handle 2 modbus slave IDs with one modbus TCP connection
|
|
|
|
}
|
|
|
|
bool HuaweiSmartLogger::update()
|
|
{
|
|
if (!m_modbusTcpMaster->connected())
|
|
return false;
|
|
|
|
if (!m_pendingUpdateReplies.isEmpty()) {
|
|
qCDebug(dcHuaweiSmartLoggerModbusTcpConnection()) << "Tried to update but there are still some update replies pending. Waiting for them to be finished...";
|
|
return true;
|
|
}
|
|
|
|
QModbusReply *reply = nullptr;
|
|
|
|
// Read Total active output power of all inverters
|
|
qCDebug(dcHuaweiSmartLoggerModbusTcpConnection()) << "--> Read \"Total active output power of all inverters\" register:" << 40525 << "size:" << 2;
|
|
reply = readInverterTotalActivePower();
|
|
if (!reply) {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Error occurred while reading \"Total active output power of all inverters\" registers from" << m_modbusTcpMaster->hostAddress().toString() << m_modbusTcpMaster->errorString();
|
|
return false;
|
|
}
|
|
|
|
if (reply->isFinished()) {
|
|
reply->deleteLater(); // Broadcast reply returns immediately
|
|
return false;
|
|
}
|
|
|
|
m_pendingUpdateReplies.append(reply);
|
|
connect(reply, &QModbusReply::finished, reply, &QModbusReply::deleteLater);
|
|
connect(reply, &QModbusReply::finished, this, [this, reply](){
|
|
m_pendingUpdateReplies.removeAll(reply);
|
|
handleModbusError(reply->error());
|
|
if (reply->error() != QModbusDevice::NoError) {
|
|
verifyUpdateFinished();
|
|
return;
|
|
}
|
|
|
|
const QModbusDataUnit unit = reply->result();
|
|
processInverterTotalActivePowerRegisterValues(unit.values());
|
|
verifyUpdateFinished();
|
|
});
|
|
|
|
connect(reply, &QModbusReply::errorOccurred, this, [this, reply] (QModbusDevice::Error error){
|
|
QModbusResponse response = reply->rawResult();
|
|
if (reply->error() == QModbusDevice::ProtocolError && response.isException()) {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Modbus reply error occurred while reading \"Total active output power of all inverters\" registers from" << m_modbusTcpMaster->hostAddress().toString() << error << reply->errorString() << ModbusDataUtils::exceptionCodeToString(response.exceptionCode());
|
|
} else {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Modbus reply error occurred while reading \"Total active output power of all inverters\" registers from" << m_modbusTcpMaster->hostAddress().toString() << error << reply->errorString();
|
|
}
|
|
});
|
|
|
|
// Read Total energy yield produced by all inverters
|
|
qCDebug(dcHuaweiSmartLoggerModbusTcpConnection()) << "--> Read \"Total energy yield produced by all inverters\" register:" << 40560 << "size:" << 2;
|
|
reply = readInverterTotalEnergyProduced();
|
|
if (!reply) {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Error occurred while reading \"Total energy yield produced by all inverters\" registers from" << m_modbusTcpMaster->hostAddress().toString() << m_modbusTcpMaster->errorString();
|
|
return false;
|
|
}
|
|
|
|
if (reply->isFinished()) {
|
|
reply->deleteLater(); // Broadcast reply returns immediately
|
|
return false;
|
|
}
|
|
|
|
m_pendingUpdateReplies.append(reply);
|
|
connect(reply, &QModbusReply::finished, reply, &QModbusReply::deleteLater);
|
|
connect(reply, &QModbusReply::finished, this, [this, reply](){
|
|
m_pendingUpdateReplies.removeAll(reply);
|
|
handleModbusError(reply->error());
|
|
if (reply->error() != QModbusDevice::NoError) {
|
|
verifyUpdateFinished();
|
|
return;
|
|
}
|
|
|
|
const QModbusDataUnit unit = reply->result();
|
|
processInverterTotalEnergyProducedRegisterValues(unit.values());
|
|
verifyUpdateFinished();
|
|
});
|
|
|
|
connect(reply, &QModbusReply::errorOccurred, this, [this, reply] (QModbusDevice::Error error){
|
|
QModbusResponse response = reply->rawResult();
|
|
if (reply->error() == QModbusDevice::ProtocolError && response.isException()) {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Modbus reply error occurred while reading \"Total energy yield produced by all inverters\" registers from" << m_modbusTcpMaster->hostAddress().toString() << error << reply->errorString() << ModbusDataUtils::exceptionCodeToString(response.exceptionCode());
|
|
} else {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Modbus reply error occurred while reading \"Total energy yield produced by all inverters\" registers from" << m_modbusTcpMaster->hostAddress().toString() << error << reply->errorString();
|
|
}
|
|
});
|
|
|
|
// Read meterData
|
|
|
|
// Temporary set the slave ID to the configured meter id, send the request and reset to broadcast...
|
|
m_slaveId = m_meterSlaveId;
|
|
reply = readBlockMeterData();
|
|
m_slaveId = 0;
|
|
qCDebug(dcHuaweiSmartLoggerModbusTcpConnection()) << "--> Read block \"meterData\" registers from:" << 32260 << "size:" << 105;
|
|
if (!reply) {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Error occurred while reading block \"meterData\" registers";
|
|
return false;
|
|
}
|
|
|
|
if (reply->isFinished()) {
|
|
reply->deleteLater(); // Broadcast reply returns immediately
|
|
return false;
|
|
}
|
|
|
|
m_pendingUpdateReplies.append(reply);
|
|
connect(reply, &QModbusReply::finished, reply, &QModbusReply::deleteLater);
|
|
connect(reply, &QModbusReply::finished, this, [this, reply](){
|
|
m_pendingUpdateReplies.removeAll(reply);
|
|
handleModbusError(reply->error());
|
|
if (reply->error() != QModbusDevice::NoError) {
|
|
verifyUpdateFinished();
|
|
return;
|
|
}
|
|
|
|
const QModbusDataUnit unit = reply->result();
|
|
const QVector<quint16> blockValues = unit.values();
|
|
processBlockMeterDataRegisterValues(blockValues);
|
|
verifyUpdateFinished();
|
|
});
|
|
|
|
connect(reply, &QModbusReply::errorOccurred, this, [reply] (QModbusDevice::Error error){
|
|
QModbusResponse response = reply->rawResult();
|
|
if (reply->error() == QModbusDevice::ProtocolError && response.isException()) {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Modbus reply error occurred while updating block \"meterData\" registers" << error << reply->errorString() << ModbusDataUtils::exceptionCodeToString(response.exceptionCode());
|
|
} else {
|
|
qCWarning(dcHuaweiSmartLoggerModbusTcpConnection()) << "Modbus reply error occurred while updating block \"meterData\" registers" << error << reply->errorString();
|
|
}
|
|
});
|
|
|
|
return true;
|
|
}
|