Via Unit 0,Via Unit 2,Register Count,R/W,Data Type,Content,Start Bit Nr.,Category 100,0,1,R,MixedBits,Digital Input 2.1,0,Basic 100,0,1,R,MixedBits,Digital Input 2.2,1,Basic 100,0,1,R,MixedBits,Digital Input 2.3,2,Basic 100,0,1,R,MixedBits,Digital Input 2.4,3,Basic 100,0,1,R,MixedBits,Digital Input 2.5,4,Basic 100,0,1,R,MixedBits,Digital Input 2.6,5,Basic 101,1,1,RW,MixedBits,Relay Output 2.1,0,Basic 101,1,1,RW,MixedBits,Relay Output 2.2,1,Basic 101,1,1,RW,MixedBits,Relay Output 2.3,2,Basic 101,1,1,RW,MixedBits,Relay Output 2.4,3,Basic 101,1,1,RW,MixedBits,Relay Output 2.5,4,Basic 102,2,1,RW,Word,Analog Output Value 2.1 (0..4000 ~ 0..10V),,Basic 103,3,1,RW,Word,Analog Output Value 2.2 (0..4000 ~ 0..10V),,Basic 104,4,1,RW,Word,Analog Output Value 2.3 (0..4000 ~ 0..10V),,Basic 105,5,1,RW,Word,Analog Output Value 2.4 (0..4000 ~ 0..10V),,Basic 106,6,2,R,Real,Analog Input Value 2.1,,Basic 108,8,2,R,Real,Analog Input Value 2.2,,Basic 110,10,2,R,Real,Analog Input Value 2.3,,Basic 112,12,2,R,Real,Analog Input Value 2.4,,Basic 114,14,1,RW,MixedBits,Group MasterWatchDog (MWD) Status,,Advanced 115,15,1,R,Word,Length of RS485 TX Queue 2.1,,Obsolete 116,16,2,RW,DWord,Counter of Digital Input 2.1,,Basic 118,18,2,RW,DWord,Counter of Digital Input 2.2,,Basic 120,20,2,RW,DWord,Counter of Digital Input 2.3,,Basic 122,22,2,RW,DWord,Counter of Digital Input 2.4,,Basic 124,24,2,RW,DWord,Counter of Digital Input 2.5,,Basic 126,26,2,RW,DWord,Counter of Digital Input 2.6,,Basic 128,28,1,RW,MixedBits,Synchronised DO/RO 2.1,0,Advanced 128,28,1,RW,MixedBits,Synchronised DO/RO 2.2,1,Advanced 128,28,1,RW,MixedBits,Synchronised DO/RO 2.3,2,Advanced 128,28,1,RW,MixedBits,Synchronised DO/RO 2.4,3,Advanced 128,28,1,RW,MixedBits,Synchronised DO/RO 2.5,4,Advanced 129,29,1,RW,MixedBits,Synchronised DO/RO Lock 2.1,0,Advanced 129,29,1,RW,MixedBits,Synchronised DO/RO Lock 2.2,1,Advanced 129,29,1,RW,MixedBits,Synchronised DO/RO Lock 2.3,2,Advanced 129,29,1,RW,MixedBits,Synchronised DO/RO Lock 2.4,3,Advanced 129,29,1,RW,MixedBits,Synchronised DO/RO Lock 2.5,4,Advanced ,100,2,RW,DWord,(Internal) RS485 Full Mode Configuration 2.1,,Obsolete ,500,1,RW,Word,RS485 TERMIOS CFlags 2.1,,Expert ,501,1,RW,Word,RS485 TERMIOS LFlags 2.1,,Expert ,502,1,RW,Word,RS485 TERMIOS IFlags 2.1,,Expert ,503,1,RW,Word,RS485 TERMIOS LDisc 2.1,,Expert ,504,1,RW,Word,RS485 ModBus Timeout 2.1,,Basic 605,505,1,W,Word,Reserved - Do Not Use,,Reserved 606,506,1,W,Word,Reserved - Do Not Use,,Reserved 607,507,1,W,Word,Reserved - Do Not Use,,Reserved 608,508,1,W,Word,Reserved - Do Not Use,,Reserved 609,509,1,W,Word,Reserved - Do Not Use,,Reserved ,510,1,RW,Word,(Internal) Stored Firmware Version,,Expert ,511,1,RW,Word,(Internal) Stored Firmware Revision,,Expert ,512,1,RW,Word,(Internal) Stored Base Firmware Revision,,Expert ,513,1,RW,Word,(Internal) Stored Expanded Flash Magic Value,,Expert ,514,1,RW,Word,(Internal) Stored PCB Revision,,Expert ,515,1,RW,Word,(Internal) Stored PCB Serial Number,,Expert ,516,1,RW,Word,(Internal) Stored HW Revision Number,,Expert 1100,1000,1,R,Word,Firmware Version,,Expert 1101,1001,1,R,Word,Number of I/Os,,Advanced 1102,1002,1,R,Word,Number of peripherals,,Advanced 1103,1003,1,R,Word,Firmware ID,,Expert 1104,1004,1,R,Word,Hardware ID,,Expert 1105,1005,2,R,DWord,PCB Serial Number,,Expert 1107,1007,1,RW,Word,Interrupt Mask,,Expert 1108,1008,1,RW,Word,Group MasterWatchDog (MWD) Timeout (in 1ms),,Advanced 1109,1009,1,R,Word,VRef of MCU,,Expert 1110,1010,1,RW,Word,Debounce time (in 100us) for DI 2.1,,Advanced 1111,1011,1,RW,Word,Debounce time (in 100us) for DI 2.2,,Advanced 1112,1012,1,RW,Word,Debounce time (in 100us) for DI 2.3,,Advanced 1113,1013,1,RW,Word,Debounce time (in 100us) for DI 2.4,,Advanced 1114,1014,1,RW,Word,Debounce time (in 100us) for DI 2.5,,Advanced 1115,1015,1,RW,Word,Debounce time (in 100us) for DI 2.6,,Advanced 1116,1016,1,RW,MixedBits,Enable DirectSwitch on DI 2.1,0,Basic 1116,1016,1,RW,MixedBits,Enable DirectSwitch on DI 2.2,1,Basic 1116,1016,1,RW,MixedBits,Enable DirectSwitch on DI 2.3,2,Basic 1116,1016,1,RW,MixedBits,Enable DirectSwitch on DI 2.4,3,Basic 1116,1016,1,RW,MixedBits,Enable DirectSwitch on DI 2.5,4,Basic 1117,1017,1,RW,MixedBits,Invert DirectSwitch Polarity on DI 2.1,0,Basic 1117,1017,1,RW,MixedBits,Invert DirectSwitch Polarity on DI 2.2,1,Basic 1117,1017,1,RW,MixedBits,Invert DirectSwitch Polarity on DI 2.3,2,Basic 1117,1017,1,RW,MixedBits,Invert DirectSwitch Polarity on DI 2.4,3,Basic 1117,1017,1,RW,MixedBits,Invert DirectSwitch Polarity on DI 2.5,4,Basic 1118,1018,1,RW,MixedBits,Enable DirectSwitch Toggle on DI 2.1,0,Basic 1118,1018,1,RW,MixedBits,Enable DirectSwitch Toggle on DI 2.2,1,Basic 1118,1018,1,RW,MixedBits,Enable DirectSwitch Toggle on DI 2.3,2,Basic 1118,1018,1,RW,MixedBits,Enable DirectSwitch Toggle on DI 2.4,3,Basic 1118,1018,1,RW,MixedBits,Enable DirectSwitch Toggle on DI 2.5,4,Basic 1119,1019,1,RW,Word,Analog Input Configuration(U/I/R) 2.1,,Basic 1120,1020,1,RW,Word,Analog Input Configuration(U/I/R) 2.2,,Basic 1121,1021,1,RW,Word,Analog Input Configuration(U/I/R) 2.3,,Basic 1122,1022,1,RW,Word,Analog Input Configuration(U/I/R) 2.4,,Basic 1123,1023,1,RW,MixedBits,RS485 Configuration 2.1,,Obsolete ,2000,220,W,Word,Reserved - Do Not Use,,Reserved