Mennekes: Use voltage instead of current to determine connected phases
This commit is contained in:
parent
ba922c7e7e
commit
e95eac7dd5
@ -482,13 +482,13 @@ void IntegrationPluginMennekes::updateECUPhaseCount(Thing *thing)
|
|||||||
}
|
}
|
||||||
qCDebug(dcMennekes()) << "Actively charging phases:" << phaseCount;
|
qCDebug(dcMennekes()) << "Actively charging phases:" << phaseCount;
|
||||||
if (phaseCount == 0) {
|
if (phaseCount == 0) {
|
||||||
if (amtronECUConnection->meterCurrentL1() > 0) {
|
if (amtronECUConnection->meterVoltageL1() > 0) {
|
||||||
phaseCount++;
|
phaseCount++;
|
||||||
}
|
}
|
||||||
if (amtronECUConnection->meterCurrentL2() > 0) {
|
if (amtronECUConnection->meterVoltageL2() > 0) {
|
||||||
phaseCount++;
|
phaseCount++;
|
||||||
}
|
}
|
||||||
if (amtronECUConnection->meterCurrentL3() > 0) {
|
if (amtronECUConnection->meterVoltageL3() > 0) {
|
||||||
phaseCount++;
|
phaseCount++;
|
||||||
}
|
}
|
||||||
qCDebug(dcMennekes()) << "Connected phases:" << phaseCount;
|
qCDebug(dcMennekes()) << "Connected phases:" << phaseCount;
|
||||||
|
|||||||
Reference in New Issue
Block a user