Merge PR #173: Menekes: Reconnect AmtronECU in case of dead Modbus TCP connection
commit
d96720cb08
|
|
@ -564,12 +564,20 @@ void IntegrationPluginMennekes::setupAmtronECUConnection(ThingSetupInfo *info)
|
||||||
}
|
}
|
||||||
});
|
});
|
||||||
|
|
||||||
connect(amtronECUConnection, &AmtronECU::reachableChanged, thing, [thing, amtronECUConnection](bool reachable){
|
connect(amtronECUConnection, &AmtronECU::reachableChanged, thing, [thing, amtronECUConnection, monitor](bool reachable){
|
||||||
qCDebug(dcMennekes()) << "Reachable changed to" << reachable << "for" << thing;
|
qCDebug(dcMennekes()) << "Reachable changed to" << reachable << "for" << thing;
|
||||||
if (reachable) {
|
if (reachable) {
|
||||||
amtronECUConnection->initialize();
|
amtronECUConnection->initialize();
|
||||||
} else {
|
} else {
|
||||||
thing->setStateValue(amtronECUConnectedStateTypeId, false);
|
thing->setStateValue(amtronECUConnectedStateTypeId, false);
|
||||||
|
|
||||||
|
// Note: sometimes the device does not repond any more on requests, but the connection is still
|
||||||
|
// up and a reconnect fixes this behavior. Let us try to reconnect in case the TCP connection is up
|
||||||
|
// or the monitor is reachable
|
||||||
|
if (amtronECUConnection->modbusTcpMaster()->connected() || monitor->reachable()) {
|
||||||
|
qCWarning(dcMennekes()) << "The amtron ECU connection is not reachable any more, but the device seems to be still reachable. Trying to reconnect...";
|
||||||
|
amtronECUConnection->modbusTcpMaster()->reconnectDevice();
|
||||||
|
}
|
||||||
}
|
}
|
||||||
});
|
});
|
||||||
|
|
||||||
|
|
|
||||||