change to float Finished
parent
ce3db06a27
commit
92aeeb6a6f
|
|
@ -542,14 +542,14 @@ void IntegrationPluginHuawei::setupFusionSolar(ThingSetupInfo *info)
|
|||
meterThings.first()->setStateValue(huaweiMeterCurrentPowerStateTypeId, -powerMeterActivePower);
|
||||
}
|
||||
});
|
||||
connect(connection, &HuaweiFusionSolar::powerMeterEnergyReturnedReadFinished, thing, [this, thing](qint32 powerMeterEnergyReturned){
|
||||
connect(connection, &HuaweiFusionSolar::powerMeterEnergyReturnedReadFinished, thing, [this, thing](float powerMeterEnergyReturned){
|
||||
Things meterThings = myThings().filterByParentId(thing->id()).filterByThingClassId(huaweiMeterThingClassId);
|
||||
if (!meterThings.isEmpty()) {
|
||||
qCDebug(dcHuawei()) << "Meter power Returned changed" << powerMeterEnergyReturned << "kWh";
|
||||
meterThings.first()->setStateValue(huaweiMeterTotalEnergyProducedStateTypeId, powerMeterEnergyReturned);
|
||||
}
|
||||
});
|
||||
connect(connection, &HuaweiFusionSolar::powerMeterEnergyAquiredReadFinished, thing, [this, thing](qint32 powerMeterEnergyAquired){
|
||||
connect(connection, &HuaweiFusionSolar::powerMeterEnergyAquiredReadFinished, thing, [this, thing](float powerMeterEnergyAquired){
|
||||
Things meterThings = myThings().filterByParentId(thing->id()).filterByThingClassId(huaweiMeterThingClassId);
|
||||
if (!meterThings.isEmpty()) {
|
||||
qCDebug(dcHuawei()) << "Meter power Aquired changed" << powerMeterEnergyAquired << "kWh";
|
||||
|
|
|
|||
Loading…