Merge PR #143: Mennekes: Use voltage instead of current to determine connected phases
commit
7e01211601
|
|
@ -502,13 +502,13 @@ void IntegrationPluginMennekes::updateECUPhaseCount(Thing *thing)
|
||||||
}
|
}
|
||||||
qCDebug(dcMennekes()) << "Actively charging phases:" << phaseCount;
|
qCDebug(dcMennekes()) << "Actively charging phases:" << phaseCount;
|
||||||
if (phaseCount == 0) {
|
if (phaseCount == 0) {
|
||||||
if (amtronECUConnection->meterCurrentL1() > 0) {
|
if (amtronECUConnection->meterVoltageL1() > 0) {
|
||||||
phaseCount++;
|
phaseCount++;
|
||||||
}
|
}
|
||||||
if (amtronECUConnection->meterCurrentL2() > 0) {
|
if (amtronECUConnection->meterVoltageL2() > 0) {
|
||||||
phaseCount++;
|
phaseCount++;
|
||||||
}
|
}
|
||||||
if (amtronECUConnection->meterCurrentL3() > 0) {
|
if (amtronECUConnection->meterVoltageL3() > 0) {
|
||||||
phaseCount++;
|
phaseCount++;
|
||||||
}
|
}
|
||||||
qCDebug(dcMennekes()) << "Connected phases:" << phaseCount;
|
qCDebug(dcMennekes()) << "Connected phases:" << phaseCount;
|
||||||
|
|
|
||||||