// SPDX-License-Identifier: GPL-3.0-or-later
/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
*
* Copyright (C) 2013 - 2024, nymea GmbH
* Copyright (C) 2024 - 2025, chargebyte austria GmbH
*
* This file is part of nymea-energy-plugin-nymea.
*
* nymea-energy-plugin-nymea.s free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* nymea-energy-plugin-nymea.s distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with nymea-energy-plugin-nymea. If not, see .
*
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
#ifndef ENERGYTIMESLOT_H
#define ENERGYTIMESLOT_H
#include
#include
#include
#include
#include
// Represents one time slot (typically 15–60 min) in the energy planning timeline.
// Predictions are all optional (0 = not yet available / stub value).
// Allocations and results are computed by the active ISchedulingStrategy.
struct EnergyTimeSlot {
// Time boundaries
QDateTime start;
QDateTime end;
// Predictions (0 = stub / not yet available)
double solarForecastW = 0; // Expected PV production (W)
double baseConsumptionW = 0; // Expected base load without flexible loads (W)
double heatingNeedW = 0; // Estimated heating demand (W)
double dhwNeedL = 0; // Estimated domestic hot water need (litres)
double electricityPrice = 0; // Spot/tariff price (EUR/kWh) from TariffManager
double electricitySellPrice = 0; // Feed-in tariff (EUR/kWh)
// Decisions computed by the Scheduler (may be overridden manually)
double allocatedToEV = 0; // Power allocated to EV charging (W)
double allocatedToHP = 0; // Power allocated to heat pump (W)
double allocatedToDHW = 0; // Power allocated to domestic hot water (W)
double allocatedToBattery = 0; // >0 battery charging, <0 battery discharging (W)
double allocatedToFeedIn = 0; // Planned grid feed-in (W)
// Derived results
double netGridPowerW = 0; // >0 grid import, <0 grid export (W)
double estimatedCostEUR = 0; // Estimated cost for this slot (negative = revenue)
double selfSufficiencyPct = 0; // Self-sufficiency percentage for this slot
// Explainability — required, must not be empty for active slots
QString decisionReason; // Human-readable explanation (e.g. "Surplus solaire +2.3 kW")
QStringList decisionRules; // Machine-readable rule tags (e.g. ["SolarSurplus","PriceBelow0.08"])
// Manual override flag (Scheduler skips re-optimising this slot when true)
bool manualOverride = false;
QString overrideReason;
bool isNull() const;
bool isActive(const QDateTime &dt = QDateTime::currentDateTimeUtc()) const;
QVariantMap toJson() const;
static EnergyTimeSlot fromJson(const QVariantMap &map);
};
Q_DECLARE_METATYPE(EnergyTimeSlot)
QDebug operator<<(QDebug debug, const EnergyTimeSlot &slot);