# USB-RLY82
STABLE NYMEA CONSUMER
Control relays connected over USB and read digital and analog inputs.
_Installationsanleitung folgt._
## Referenz
**Manufacturer:** Robot electronics
**Plugin:** `UsbRly82`
#### Supported models
| Model | Role | Transport | Pairing | Quantities |
| --- | --- | --- | --- | --- |
| **USB-RLY82** | gateway | — | Auto-discovery / Automatic | 20 |
#### Per-model detail
??? abstract "USB-RLY82 — `usbRelay`"
_Settings:_
| Key | Label | Type | Range | Default | Read-only |
| --- | --- | --- | --- | --- | --- |
| `serialNumber` | Serial number | QString | — | — | no |
_Measured quantities:_
| Key | Quantity | Type | Unit |
| --- | --- | --- | --- |
| `connected` | Connected | bool | — |
| `powerRelay1` | Power relay 1 | bool | — |
| `powerRelay2` | Power relay 2 | bool | — |
| `digitalInputChannel1` | Channel 1 | bool | — |
| `digitalInputChannel2` | Channel 2 | bool | — |
| `digitalInputChannel3` | Channel 3 | bool | — |
| `digitalInputChannel4` | Channel 4 | bool | — |
| `digitalInputChannel5` | Channel 5 | bool | — |
| `digitalInputChannel6` | Channel 6 | bool | — |
| `digitalInputChannel7` | Channel 7 | bool | — |
| `digitalInputChannel8` | Channel 8 | bool | — |
| `analogInputChannel1` | Analog Channel 1 | double | — |
| `analogInputChannel2` | Analog Channel 2 | double | — |
| `analogInputChannel3` | Analog Channel 3 | double | — |
| `analogInputChannel4` | Analog Channel 4 | double | — |
| `analogInputChannel5` | Analog Channel 5 | double | — |
| `analogInputChannel6` | Analog Channel 6 | double | — |
| `analogInputChannel7` | Analog Channel 7 | double | — |
| `analogInputChannel8` | Analog Channel 8 | double | — |
| `version` | Version | QString | — |