# my-PV STABLE NYMEA COMMUNITY Control my-PV network enabled heating rods. _Installation guide coming soon._ ## Reference **Manufacturer:** my-PV **Plugin:** `Mypv` #### Supported models | Model | Role | Transport | Pairing | Quantities | | --- | --- | --- | --- | --- | | **AC Elwa E** | heating, temperaturesensor | — | Discovery | 6 | #### Per-model detail ??? abstract "AC Elwa E — `elwa`" _Settings:_ | Key | Label | Type | Range | Default | Read-only | | --- | --- | --- | --- | --- | --- | | `ipAddress` | IP address | QString | — | — | no | | `serialNumber` | Serial number | QString | — | — | no | _Measured quantities:_ | Key | Quantity | Type | Unit | | --- | --- | --- | --- | | `connected` | Connected | bool | — | | `power` | Power | bool | — | | `heatingPower` | Power consumption | int | Watt | | `temperature` | Water temperature | double | DegreeCelsius | | `targetWaterTemperature` | Target water temperature | double | DegreeCelsius | | `status` | Status | QString | — |