docs(moteur): « Comment le moteur décide » aligné sur le code des règles
All checks were successful
Build & Deploy docs / build-deploy (push) Successful in 3m52s
All checks were successful
Build & Deploy docs / build-deploy (push) Successful in 3m52s
Relu contre le moteur (main 61db6cf) : en temps réel la protection ne bride que les bornes, les autres charges sont délestées au cycle suivant ; cycle chaque minute ; repli à 90 s de silence du compteur, états sûrs. Ordre réel : mesure et marge de soutirage, échéances VE, réserve batterie, passe éco (demandes ponctuelles puis obligations étalées) avant la cascade confort ; recrédit, plancher, verrous et indisponibilité appliqués charge par charge ; une commande par charge. Retiré : « si l'installateur l'a autorisé » (aucune autorisation dédiée). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Ry3vBrJT1tHdxAaXdCWi6L
This commit is contained in:
parent
eb7d727d17
commit
e6a5f50467
@ -12,51 +12,76 @@ Integratoren; die folgenden Seiten erläutern die einzelnen Funktionen.
|
||||
Die Engine trennt Sicherheit und Verteilung. Es sind zwei getrennte Schleifen, mit
|
||||
unterschiedlichem Takt und unterschiedlicher Priorität.
|
||||
|
||||
- **Die Sicherheitsschleife, in Echtzeit.** Bei jeder Änderung der gemessenen Bilanz liest
|
||||
sie den Strom jeder Phase am Netzanschlusszähler. Überschreitet eine Phase die
|
||||
eingestellte Grenze, regelt sie die Verbraucher sofort ab ([Lastabwurf](delestage.md))
|
||||
und gibt wieder frei, sobald genug Reserve da ist. Sie wartet nicht auf den Zyklus und
|
||||
hat Vorrang vor allem anderen.
|
||||
- **Der Verteilungszyklus, etwa einmal pro Minute.** Er verteilt die verfügbare Leistung
|
||||
auf die Verbraucher. Nur hier greift eine Strategie ein: die eingebauten Regeln oder,
|
||||
falls angeschlossen, ein [Optimierer](../optimiseur/index.md).
|
||||
- **Der Überlastschutz, bei jeder Messung.** Sobald sich die gemessene Bilanz ändert,
|
||||
liest die Engine den Strom jeder Phase am Netzanschlusszähler. Überschreitet eine Phase
|
||||
die eingestellte Grenze, senkt sie **sofort** den Ladestrom der Wallboxen und gibt ihn
|
||||
wieder frei, sobald genug Reserve da ist. Die übrigen Verbraucher (Warmwasserbereiter,
|
||||
Wärmepumpe, Relais) werden zu Beginn des nächsten Zyklus abgeworfen
|
||||
([Lastabwurf](delestage.md)). Dieser Schutz hat Vorrang vor jeder
|
||||
Verteilungsentscheidung.
|
||||
- **Der Verteilungszyklus, jede Minute.** Er verteilt die verfügbare Leistung auf die
|
||||
Verbraucher, auf Basis der Minutenmessung der elektrischen Bilanz, und läuft sofort
|
||||
erneut, wenn Sie eine Einstellung ändern. Nur hier greift eine Strategie ein: die
|
||||
eingebauten Regeln oder, falls angeschlossen, ein [Optimierer](../optimiseur/index.md).
|
||||
|
||||
Antwortet der Netzanschlusszähler nicht mehr, setzt die Engine die Verteilung aus und geht
|
||||
in den Sicherheits-Rückfall: ohne Messung keine Entscheidung.
|
||||
**Schweigt der Netzanschlusszähler** (mehr als 90 s ohne Messwert), setzt die Engine die
|
||||
Verteilung aus und bringt die Verbraucher in eine sichere Stellung: regelbare Verbraucher
|
||||
auf 0 W, Relais offen, Wärmepumpe im Normalbetrieb, bereits ladende Wallboxen auf
|
||||
Mindeststrom, kein neuer Verbraucher wird gestartet. Der Überlastschutz bleibt aktiv. Die
|
||||
Verteilung setzt im Zyklus nach der Rückkehr des Zählers wieder ein.
|
||||
|
||||
## Die Regeln, in ihrer Reihenfolge
|
||||
|
||||
In jedem Zyklus durchläuft die Engine dieselben Schritte, in derselben Reihenfolge.
|
||||
|
||||
1. **Messen.** Ausgangspunkt ist der Messwert des Netzanschlusszählers. Die Engine rechnet
|
||||
hinzu, was die von ihr gesteuerten Verbraucher bereits aufnehmen: Ein laufender
|
||||
Verbraucher wird nicht gegen sich selbst gerechnet.
|
||||
2. **Berücksichtigen, was festliegt.** Ein gesperrter Verbraucher (Mindestlauf- oder
|
||||
Mindeststillstandszeit, Wartezeit zwischen zwei Stromänderungen) behält seine
|
||||
zugesagte Leistung, und sie wird vom Budget abgezogen. Ein nicht verfügbarer
|
||||
Verbraucher erhält keinen Sollwert, sein Verbrauch wird aber weiter gezählt.
|
||||
3. **Bedarfe mit Frist bedienen.** Eine tägliche Pflicht (etwa eine Mindestenergie für den
|
||||
Warmwasserbereiter bis zu einer bestimmten Uhrzeit) oder eine einmalige Anforderung aus
|
||||
der App kann, wenn die Frist naht und der Überschuss nicht gereicht hat, den Rest aus
|
||||
dem Netz beziehen — sofern der Installateur das erlaubt hat.
|
||||
4. **Den Überschuss kaskadiert verteilen.** Die Verbraucher werden in der von Ihnen
|
||||
festgelegten **Priorität** bedient (1 = zuerst). Jeder erhält, was vom Budget übrig
|
||||
ist, innerhalb seiner Grenzen, und das Budget wird entsprechend verringert. Es gibt
|
||||
**ein einziges** Budget: Ohne es sähen drei Manager jeweils „2 kW Überschuss“ und
|
||||
zögen zusammen 6.
|
||||
5. **Abschalten, was nicht starten kann.** Unterhalb seiner Mindestleistung bleibt ein
|
||||
Verbraucher aus, statt halb zu laufen.
|
||||
1. **Messen.** Ausgangspunkt ist der Messwert des Netzanschlusszählers (Einspeisung und
|
||||
Bezug). Daraus leitet die Engine auch den **Bezugsspielraum** ab: was die Anlage noch
|
||||
aus dem Netz beziehen kann, ohne die Phasengrenze zu überschreiten. Kein Netzbezug,
|
||||
gleich aus welchem Grund, geht darüber hinaus.
|
||||
2. **Ladefristen bedienen.** Ein Fahrzeug, das bis zu einer bestimmten Uhrzeit geladen
|
||||
sein muss, wird aus dem Netz bedient, außerhalb der Überschussverteilung.
|
||||
3. **Die Batterie schützen.** Liegt ein Hausspeicher unter seiner Reserveschwelle, geht der
|
||||
Überschuss zuerst an ihn: Die gesteuerten Verbraucher erhalten nichts davon. Oberhalb
|
||||
der Schwelle zählt, was er aufnimmt, als verfügbarer Überschuss. Seine Entladung wird
|
||||
nie als Überschuss gezählt.
|
||||
4. **Zugesicherte Bedarfe („Eco“-Durchlauf).** Zuerst die **einmaligen Anforderungen** aus
|
||||
der App („jetzt heizen“): Der Verbraucher erhält seine volle Leistung, unabhängig von
|
||||
seinem Rang. Danach die **täglichen Pflichten**, etwa eine Mindestenergie für den
|
||||
Warmwasserbereiter bis zu einer bestimmten Uhrzeit: Die Engine kauft das Fehlende aus
|
||||
dem Netz, gleichmäßig bis zur Frist verteilt, und schaltet auf volle Leistung, wenn nur
|
||||
noch die gerade nötige Zeit bleibt. Diese Bezüge bleiben im Bezugsspielraum.
|
||||
5. **Den Überschuss kaskadiert verteilen („Komfort“-Durchlauf).** Die Verbraucher werden
|
||||
in der von Ihnen festgelegten **Priorität** bedient (1 = zuerst). Jeder erhält, was vom
|
||||
Budget übrig ist, innerhalb seiner Grenzen, und das Budget wird entsprechend
|
||||
verringert. Es gibt **ein einziges** Budget: Ohne es sähen drei Manager jeweils „2 kW
|
||||
Überschuss“ und zögen zusammen 6. Der Reihe nach, für jeden Verbraucher:
|
||||
- was er bereits aufnimmt, wird ihm gutgeschrieben: Ein laufender Verbraucher wird
|
||||
nicht gegen sich selbst gerechnet;
|
||||
- unterhalb seiner Mindestleistung bleibt er aus, statt halb zu laufen, und das Budget
|
||||
geht an den nächsten. Eine Wallbox kann dennoch mit einem kleinen Zuschuss aus dem
|
||||
Netz starten, innerhalb der eingestellten Toleranz;
|
||||
- ein **gesperrter** Verbraucher (Mindestlauf- oder Mindeststillstandszeit, Wartezeit
|
||||
zwischen zwei Änderungen) behält seine aktuelle Leistung;
|
||||
- ein **nicht verfügbarer** Verbraucher behält seine aktuelle Leistung, ohne neuen
|
||||
Sollwert; sein Verbrauch wird weiter gezählt.
|
||||
6. **Ein Befehl pro Verbraucher.** Zugesicherter Bedarf und Überschussanteil desselben
|
||||
Verbrauchers werden zusammengeführt: Jeder Verbraucher erhält einen einzigen Sollwert,
|
||||
mit seinem Grund.
|
||||
|
||||
### Die Grenzen jedes Verbrauchers
|
||||
|
||||
Jeder Verbraucher hat vom Installateur eingetragene Grenzen, die **jede** Entscheidung
|
||||
einhält, gleich welche Strategie:
|
||||
|
||||
- eine **Unter-** und eine **Obergrenze** der Leistung (bzw. des Stroms bei einer Wallbox);
|
||||
- eine **Unter-** und eine **Obergrenze** der Leistung. Bei einer Wallbox sind sie als
|
||||
Strom angegeben (mal Anzahl der Phasen), und die Obergrenze wird zusätzlich durch die
|
||||
Phasengrenze beschränkt;
|
||||
- **Sperren gegen Takten**: Mindestlauf- und Mindeststillstandszeit, Wartezeit zwischen
|
||||
zwei Änderungen;
|
||||
zwei Änderungen. Eine Wallbox hat eigene (Wartezeit zwischen Ein und Aus, Wartezeit
|
||||
zwischen zwei Stromänderungen);
|
||||
- bei einer SG-Ready-Wärmepumpe: der Zustand wird nach der geschätzten Leistung jedes
|
||||
Zustands gewählt, mit einer Mindesthaltedauer.
|
||||
Zustands gewählt, mit Hysterese und Mindesthaltedauer. Der Sperrzustand wird nie durch
|
||||
den Überschuss ausgelöst.
|
||||
|
||||
## Der Grund jeder Entscheidung
|
||||
|
||||
@ -68,20 +93,20 @@ Mindestleistung“, „Ladefrist“… Die Liste der Codes ist mit dem
|
||||
|
||||
## Die Messung, nie das Ergebnis der Steuerung
|
||||
|
||||
Der Überschuss wird aus der **Rohmessung** berechnet: Erzeugung und Zähler, so wie sie
|
||||
gemessen werden. Nie aus der Nettobilanz nach der Steuerung: Die Engine würde sich selbst
|
||||
lesen und schwingen.
|
||||
Der Überschuss wird aus der **Rohmessung** des Netzanschlusszählers berechnet, so wie sie
|
||||
gemessen wird. Nie aus einer nach der Steuerung neu berechneten Bilanz: Die Engine würde
|
||||
sich selbst lesen und schwingen.
|
||||
|
||||
## Ohne Internet
|
||||
|
||||
All das läuft auf der Box. Ohne Internet steuert die Engine, wendet die Sicherheit an und
|
||||
antwortet der App in Ihrem lokalen Netz. Nur die [PV-Prognose](prevision-pv.md) setzt
|
||||
aus — und sie dient in der Community-Version nicht zur Entscheidung, ebenso wenig wie der
|
||||
[eingegebene Tarif](../tarifs.md): Beide werden angezeigt und gespeichert, aber von den
|
||||
Regeln nie verwendet.
|
||||
aus. In der Community-Version fließen weder die Prognose noch der
|
||||
[eingegebene Tarif](../tarifs.md) in die Entscheidungen der Regeln ein: Beide werden
|
||||
angezeigt und gespeichert, aber nie zum Entscheiden verwendet.
|
||||
|
||||
## Und ein Optimierer?
|
||||
|
||||
Ein Optimierer kann anhand der Prognosen einen Plan über mehrere Stunden vorschlagen. Er
|
||||
ersetzt den Verteilungsschritt, **nie** die Sicherheitsschleife oder die Grenzen. Siehe
|
||||
ersetzt den Verteilungsschritt, **nie** den Überlastschutz oder die Grenzen. Siehe
|
||||
Abschnitt [Optimierer](../optimiseur/index.md).
|
||||
|
||||
@ -3,80 +3,105 @@
|
||||
<span class="badge community">COMMUNITY</span>
|
||||
|
||||
The box's energy engine drives your loads on its own: EV chargers, water heater,
|
||||
SG-Ready heat pump, relays. It is free software (GPL-3.0) and it is what decides in the
|
||||
**Community** edition. This page describes its logic for installers and integrators; the
|
||||
following pages detail each feature.
|
||||
SG-Ready heat pump, relays. It is free software (GPL-3.0) and it is the one that decides
|
||||
in the **Community** edition. This page describes its logic for installers and
|
||||
integrators; the following pages detail each feature.
|
||||
|
||||
## Two loops, two priorities
|
||||
|
||||
The engine keeps safety apart from allocation. They are two separate loops, running at
|
||||
different rates and with different priorities.
|
||||
|
||||
- **The safety loop, in real time.** On every change in the measured balance, it reads the
|
||||
current of each phase at the grid meter. If a phase exceeds the configured limit, it
|
||||
cuts loads back immediately ([load shedding](delestage.md)), then releases them once
|
||||
there is headroom again. It does not wait for the cycle and overrides everything else.
|
||||
- **The allocation cycle, about once a minute.** It shares the available power between
|
||||
the loads. This is the only place a strategy acts: the built-in rules, or an
|
||||
[optimizer](../optimiseur/index.md) if one is connected.
|
||||
- **Overload protection, on every measurement.** As soon as the measured balance
|
||||
changes, the engine reads the current of each phase at the grid meter. If a phase
|
||||
exceeds the configured limit, it **immediately** lowers the current of the EV chargers,
|
||||
then releases it when the margin returns. The other loads (water heater, heat pump,
|
||||
relays) are shed at the start of the next cycle ([load management](delestage.md)). This
|
||||
protection overrides any allocation decision.
|
||||
- **The allocation cycle, every minute.** It shares the available power between the
|
||||
loads, on the one-minute measurement of the electrical balance, and runs again right
|
||||
away when you change a setting. It is the only place where a strategy comes in: the
|
||||
built-in rules, or an [optimizer](../optimiseur/index.md) if one is connected.
|
||||
|
||||
If the grid meter stops answering, the engine suspends allocation and falls back to safety
|
||||
mode: no measurement, no decision.
|
||||
**If the grid meter goes silent** (more than 90 s without a reading), the engine suspends
|
||||
allocation and puts the loads in a safe position: adjustable loads at 0 W, relays open,
|
||||
heat pump in normal operation, chargers already charging brought down to minimum
|
||||
current, no new load started. Overload protection stays active. Allocation resumes on the
|
||||
cycle after the meter comes back.
|
||||
|
||||
## The rules, in order
|
||||
|
||||
On every cycle, the engine runs the same steps, in the same order.
|
||||
On every cycle, the engine applies the same steps, in the same order.
|
||||
|
||||
1. **Measure.** The starting point is what the grid meter measures. The engine adds back
|
||||
what the loads it drives are already drawing: a running load is not counted against
|
||||
itself.
|
||||
2. **Account for what is locked.** A load under a lock (minimum on or off time, delay
|
||||
between two current changes) keeps the power it has committed, and that power is taken
|
||||
out of the budget. An unavailable load receives no setpoint, but what it draws is still
|
||||
counted.
|
||||
3. **Serve needs with a deadline.** A daily obligation (for example a minimum energy for
|
||||
the water heater before a given time) or a one-off request made from the app may, as
|
||||
the deadline nears and the surplus has not been enough, take the remainder from the
|
||||
grid — if the installer has allowed it.
|
||||
4. **Cascade the surplus.** Loads are served in the **priority** order you set (1 = served
|
||||
first). Each receives what is left of the budget, within its bounds, and the budget is
|
||||
reduced accordingly. There is **one** budget: without it, three managers would each see
|
||||
"2 kW of surplus" and draw 6 between them.
|
||||
5. **Stop what cannot start.** Below its minimum power, a load stays off rather than
|
||||
running at half.
|
||||
1. **Measure.** The starting point is what the grid meter measures (export and import).
|
||||
The engine also derives the **draw margin** from it: what the installation can still
|
||||
take from the grid without exceeding the phase limit. No grid purchase, whatever its
|
||||
reason, goes beyond it.
|
||||
2. **Serve charging deadlines.** A vehicle that must be charged by a given time is served
|
||||
from the grid, outside the surplus sharing.
|
||||
3. **Protect the battery.** If a home battery is below its reserve threshold, the surplus
|
||||
goes to it first: the controlled loads get none of it. Above the threshold, what it
|
||||
absorbs counts as available surplus. Its discharge is never counted as surplus.
|
||||
4. **Guaranteed needs ("eco" pass).** First the **one-off requests** made from the app
|
||||
("heat now"): the load gets its full power, whatever its rank. Then the **daily
|
||||
obligations**, for example a minimum amount of energy for the water heater before a
|
||||
given time: the engine buys the missing energy from the grid, spread evenly until the
|
||||
deadline, and switches to full power when only the time strictly needed is left. These
|
||||
purchases stay within the draw margin.
|
||||
5. **Share the surplus in cascade ("comfort" pass).** Loads are served in the
|
||||
**priority** order you set (1 = served first). Each receives what is left of the
|
||||
budget, within its bounds, and the budget is decreased accordingly. There is **one**
|
||||
budget: without it, three managers would each see "2 kW of surplus" and draw 6. In
|
||||
turn, for each load:
|
||||
- what it already consumes is given back to it: a running load is not counted against
|
||||
itself;
|
||||
- below its minimum power, it stays off rather than running at half power, and the
|
||||
budget moves on to the next one. An EV charger may still start with a small top-up
|
||||
from the grid, within the configured tolerance;
|
||||
- a load under **lock** (minimum on or off time, delay between two changes) keeps its
|
||||
current power;
|
||||
- an **unavailable** load keeps its current power, with no new setpoint; what it
|
||||
consumes is still counted.
|
||||
6. **One command per load.** The guaranteed need and the surplus share of the same load
|
||||
are merged: each load receives a single setpoint, with its reason.
|
||||
|
||||
### The bounds of each load
|
||||
|
||||
Each load carries bounds entered by the installer, which **every** decision respects,
|
||||
whatever the strategy:
|
||||
|
||||
- a power **floor** and **ceiling** (or current, for an EV charger);
|
||||
- **anti-flapping locks**: minimum on and off time, delay between two changes;
|
||||
- for an SG-Ready heat pump: the state is chosen from the estimated power of each state,
|
||||
with a minimum hold time.
|
||||
- a power **floor** and **ceiling**. For an EV charger they are in current (times the
|
||||
number of phases), and the ceiling is further capped by the phase limit;
|
||||
- **anti-flapping locks**: minimum on and off time, delay between two changes. An EV
|
||||
charger has its own (delay between on and off, delay between two current changes);
|
||||
- for an SG-Ready heat pump: the state chosen from the estimated power of each state,
|
||||
with hysteresis and a minimum hold time. The blocking state is never commanded by the
|
||||
surplus.
|
||||
|
||||
## The reason for every decision
|
||||
|
||||
The engine takes no decision without stating why. Every decision carries a non-empty
|
||||
**reason** (`decisionReason`): a stable code and its parameters, which the app displays in
|
||||
your language — "surplus insufficient", "below minimum power", "charging deadline"… The
|
||||
list of codes is published with the [optimizer protocol](../optimiseur/protocole.md#reponse).
|
||||
The engine makes no decision without stating why. Every decision carries a non-empty
|
||||
**reason** (`decisionReason`): a stable code and its parameters, which the app displays
|
||||
in your language — "insufficient surplus", "below minimum power", "charging deadline"…
|
||||
The list of codes is published with the
|
||||
[optimizer protocol](../optimiseur/protocole.md#reponse).
|
||||
|
||||
## The measurement, never the result of control
|
||||
|
||||
Surplus is computed from the **raw measurement**: production and meter, as measured. Never
|
||||
from the net balance after control: the engine would be reading itself, and oscillate.
|
||||
The surplus is computed on the **raw measurement** of the grid meter, as measured. Never
|
||||
on a balance recomputed after control: the engine would be reading itself and would
|
||||
oscillate.
|
||||
|
||||
## Without internet
|
||||
|
||||
All of the above runs on the box. Without internet, the engine keeps driving the loads,
|
||||
enforces safety and answers the app on your local network. Only the
|
||||
[PV forecast](prevision-pv.md) stops — and it is not used for decisions in the Community
|
||||
edition, any more than the [entered tariff](../tarifs.md): both are displayed and
|
||||
recorded, never used by the rules.
|
||||
Everything above runs on the box. Without internet, the engine controls, applies safety
|
||||
and answers the app on your local network. Only the [PV forecast](prevision-pv.md)
|
||||
stops. In the Community edition, neither the forecast nor the
|
||||
[entered tariff](../tarifs.md) enters the decisions of the rules: both are displayed and
|
||||
recorded, never used to decide.
|
||||
|
||||
## What about an optimizer?
|
||||
## And an optimizer?
|
||||
|
||||
An optimizer can propose a plan over several hours, based on the forecasts. It replaces
|
||||
the allocation step, **never** the safety loop or the bounds. See the
|
||||
An optimizer can propose a plan over several hours, based on forecasts. It replaces the
|
||||
allocation step, **never** the overload protection or the bounds. See the
|
||||
[Optimizer](../optimiseur/index.md) section.
|
||||
|
||||
@ -12,49 +12,75 @@ les pages suivantes détaillent chaque fonction.
|
||||
Le moteur sépare la sécurité de la répartition. Ce sont deux boucles distinctes, qui ne
|
||||
tournent pas au même rythme et n'ont pas la même priorité.
|
||||
|
||||
- **La boucle de sécurité, en temps réel.** À chaque variation du bilan mesuré, elle lit
|
||||
le courant de chaque phase au compteur de tête. Si une phase dépasse la limite
|
||||
configurée, elle réduit immédiatement les charges ([délestage](delestage.md)), puis
|
||||
relâche quand la marge revient. Elle n'attend pas le cycle et prime sur tout le reste.
|
||||
- **Le cycle de répartition, environ une fois par minute.** Il répartit la puissance
|
||||
disponible entre les charges. C'est le seul endroit où une stratégie intervient : les
|
||||
règles intégrées, ou un [optimiseur](../optimiseur/index.md) s'il est branché.
|
||||
- **La protection contre la surcharge, à chaque mesure.** Dès que le bilan mesuré change,
|
||||
le moteur lit le courant de chaque phase au compteur de tête. Si une phase dépasse la
|
||||
limite configurée, il réduit **immédiatement** le courant des bornes de recharge, puis
|
||||
le relâche quand la marge revient. Les autres charges (chauffe-eau, pompe à chaleur,
|
||||
relais) sont délestées au début du cycle suivant ([délestage](delestage.md)). Cette
|
||||
protection prime sur toute décision de répartition.
|
||||
- **Le cycle de répartition, chaque minute.** Il répartit la puissance disponible entre
|
||||
les charges, sur la mesure d'une minute du bilan électrique, et repart aussitôt quand
|
||||
vous changez un réglage. C'est le seul endroit où une stratégie intervient : les règles
|
||||
intégrées, ou un [optimiseur](../optimiseur/index.md) s'il est branché.
|
||||
|
||||
Si le compteur de tête ne répond plus, le moteur suspend la répartition et passe en repli
|
||||
de sécurité : sans mesure, il ne décide pas.
|
||||
**Si le compteur de tête se tait** (plus de 90 s sans mesure), le moteur suspend la
|
||||
répartition et met les charges en position sûre : charges réglables à 0 W, relais
|
||||
ouverts, pompe à chaleur en fonctionnement normal, bornes déjà en charge ramenées au
|
||||
courant minimum, aucune nouvelle charge démarrée. La protection contre la surcharge reste
|
||||
active. La répartition reprend au cycle qui suit le retour du compteur.
|
||||
|
||||
## Les règles, dans l'ordre
|
||||
|
||||
À chaque cycle, le moteur applique les mêmes étapes, dans le même ordre.
|
||||
|
||||
1. **Mesurer.** Le point de départ est ce que mesure le compteur de tête. Le moteur y
|
||||
rajoute ce que consomment déjà les charges qu'il pilote : une charge en marche n'est
|
||||
pas comptée contre elle-même.
|
||||
2. **Tenir compte de ce qui est figé.** Une charge sous verrou (durée minimale de marche
|
||||
ou d'arrêt, délai entre deux changements de courant) garde sa puissance engagée, et
|
||||
celle-ci est retirée du budget. Une charge indisponible ne reçoit aucune consigne, mais
|
||||
ce qu'elle consomme reste compté.
|
||||
3. **Servir les besoins à échéance.** Une obligation quotidienne (par exemple une énergie
|
||||
minimale pour le chauffe-eau avant une heure donnée) ou une demande ponctuelle faite
|
||||
depuis l'application peut, quand l'échéance approche et que le surplus n'a pas suffi,
|
||||
prendre le complément sur le réseau — si l'installateur l'a autorisé.
|
||||
4. **Répartir le surplus en cascade.** Les charges sont servies dans l'ordre de
|
||||
**priorité** que vous avez fixé (1 = servie en premier). Chacune reçoit ce qui reste du
|
||||
budget, dans ses bornes, et le budget est décrémenté d'autant. Le budget est **unique** :
|
||||
sans lui, trois gestionnaires verraient chacun « 2 kW de surplus » et en tireraient 6.
|
||||
5. **Arrêter ce qui ne peut pas démarrer.** Sous sa puissance minimale, une charge reste
|
||||
arrêtée plutôt que de fonctionner à moitié.
|
||||
1. **Mesurer.** Le point de départ est ce que mesure le compteur de tête (injection et
|
||||
soutirage). Le moteur en tire aussi la **marge de soutirage** : ce que l'installation
|
||||
peut encore prendre au réseau sans dépasser la limite de phase. Aucun achat au réseau,
|
||||
quelle qu'en soit la raison, ne la dépasse.
|
||||
2. **Servir les recharges à échéance.** Un véhicule qui doit être chargé pour une heure
|
||||
donnée est servi sur le réseau, hors du partage du surplus.
|
||||
3. **Protéger la batterie.** Si une batterie domestique est sous son seuil de réserve, le
|
||||
surplus lui revient d'abord : les charges pilotées n'en reçoivent pas. Au-dessus du
|
||||
seuil, ce qu'elle absorbe compte comme surplus disponible. Sa décharge n'est jamais
|
||||
comptée comme du surplus.
|
||||
4. **Les besoins garantis (passe « éco »).** D'abord les **demandes ponctuelles** faites
|
||||
depuis l'application (« chauffer maintenant ») : la charge reçoit sa pleine puissance,
|
||||
quel que soit son rang. Ensuite les **obligations quotidiennes**, par exemple une
|
||||
énergie minimale pour le chauffe-eau avant une heure donnée : le moteur achète au
|
||||
réseau ce qui manque, réparti régulièrement jusqu'à l'échéance, et passe à pleine
|
||||
puissance quand il ne reste plus que le temps juste nécessaire. Ces achats restent dans
|
||||
la marge de soutirage.
|
||||
5. **Partager le surplus en cascade (passe « confort »).** Les charges sont servies dans
|
||||
l'ordre de **priorité** que vous avez fixé (1 = servie en premier). Chacune reçoit ce
|
||||
qui reste du budget, dans ses bornes, et le budget est décrémenté d'autant. Le budget
|
||||
est **unique** : sans lui, trois gestionnaires verraient chacun « 2 kW de surplus » et
|
||||
en tireraient 6. À son tour, pour chaque charge :
|
||||
- ce qu'elle consomme déjà lui est rendu : une charge en marche n'est pas comptée
|
||||
contre elle-même ;
|
||||
- sous sa puissance minimale, elle reste arrêtée plutôt que de fonctionner à moitié,
|
||||
et le budget passe à la suivante. Une borne de recharge peut toutefois démarrer avec
|
||||
un petit complément pris au réseau, dans la tolérance réglée ;
|
||||
- une charge sous **verrou** (durée minimale de marche ou d'arrêt, délai entre deux
|
||||
changements) garde sa puissance du moment ;
|
||||
- une charge **indisponible** garde sa puissance actuelle, sans nouvelle consigne ; ce
|
||||
qu'elle consomme reste compté.
|
||||
6. **Une seule commande par charge.** Le besoin garanti et la part de surplus d'une même
|
||||
charge sont fusionnés : chaque charge reçoit une seule consigne, avec son motif.
|
||||
|
||||
### Les bornes de chaque charge
|
||||
|
||||
Chaque charge porte des bornes saisies par l'installateur, que **toute** décision
|
||||
respecte, quelle que soit la stratégie :
|
||||
|
||||
- un **plancher** et un **plafond** de puissance (ou de courant, pour une borne) ;
|
||||
- un **plancher** et un **plafond** de puissance. Pour une borne de recharge, ils sont en
|
||||
courant (multiplié par le nombre de phases), et le plafond est en plus limité par la
|
||||
limite de phase ;
|
||||
- des **verrous anti-battement** : durée minimale de marche et d'arrêt, délai entre deux
|
||||
changements ;
|
||||
changements. Une borne de recharge a les siens (délai entre marche et arrêt, délai entre
|
||||
deux changements de courant) ;
|
||||
- pour une PAC SG-Ready : l'état choisi selon la puissance estimée de chaque état, avec
|
||||
une durée minimale de maintien.
|
||||
une hystérésis et une durée minimale de maintien. L'état de blocage n'est jamais
|
||||
commandé par le surplus.
|
||||
|
||||
## Le motif de chaque décision
|
||||
|
||||
@ -66,20 +92,20 @@ minimale », « échéance de recharge »… La liste des codes est publiée ave
|
||||
|
||||
## La mesure, jamais le résultat du pilotage
|
||||
|
||||
Le surplus est calculé sur la **mesure brute** : production et compteur, tels qu'ils
|
||||
sont mesurés. Jamais sur le bilan net après pilotage : le moteur se lirait lui-même et
|
||||
Le surplus est calculé sur la **mesure brute** du compteur de tête, telle qu'elle est
|
||||
mesurée. Jamais sur un bilan recalculé après pilotage : le moteur se lirait lui-même et
|
||||
oscillerait.
|
||||
|
||||
## Sans internet
|
||||
|
||||
Tout ce qui précède tourne sur la box. Sans internet, le moteur pilote, applique la
|
||||
sécurité et répond à l'application sur votre réseau local. Seule la
|
||||
[prévision PV](prevision-pv.md) s'interrompt — et elle ne sert pas à décider dans la
|
||||
version Community, pas plus que le [tarif saisi](../tarifs.md) : tous deux sont affichés
|
||||
et enregistrés, jamais utilisés par les règles.
|
||||
[prévision PV](prevision-pv.md) s'interrompt. Dans la version Community, ni la prévision
|
||||
ni le [tarif saisi](../tarifs.md) n'entrent dans les décisions des règles : tous deux
|
||||
sont affichés et enregistrés, jamais utilisés pour décider.
|
||||
|
||||
## Et un optimiseur ?
|
||||
|
||||
Un optimiseur peut proposer un plan sur plusieurs heures, à partir des prévisions. Il
|
||||
remplace l'étape de répartition, **jamais** la boucle de sécurité ni les bornes. Voir la
|
||||
section [Optimiseur](../optimiseur/index.md).
|
||||
remplace l'étape de répartition, **jamais** la protection contre la surcharge ni les
|
||||
bornes. Voir la section [Optimiseur](../optimiseur/index.md).
|
||||
|
||||
@ -20,7 +20,8 @@ Abend lassen usw.
|
||||
- Die Engine führt nur das **aktuelle Zeitfenster** des Plans aus. Der Rest wird als
|
||||
Prognose angezeigt und im nächsten Zyklus neu angefragt.
|
||||
- Jeder Sollwert wird durch die Grenzen des Verbrauchers (Unter-, Obergrenze, Sperren
|
||||
gegen Takten) und durch die **Sicherheitsschleife** in Echtzeit **gedeckelt**; diese
|
||||
gegen Takten) und durch den **Überlastschutz** ([Wie die Engine
|
||||
entscheidet](../fonctionnalites/moteur.md)) **gedeckelt**; diese
|
||||
bleibt bei der Engine und hat Vorrang vor allem. Ein Optimierer kann keine Sperre
|
||||
umgehen.
|
||||
- Jede Aktion muss ihren **Grund** tragen. Eine Aktion ohne Grund wird verworfen.
|
||||
|
||||
@ -18,7 +18,8 @@ expected production peak, keep headroom for evening charging, and so on.
|
||||
- The engine only executes the **current slot** of the plan. The rest is shown as a
|
||||
forecast, and requested again on the next cycle.
|
||||
- Every setpoint is **capped** by the load's bounds (floor, ceiling, anti-flapping locks)
|
||||
and by the real-time **safety loop**, which stays with the engine and overrides
|
||||
and by the **overload protection** ([How the engine
|
||||
decides](../fonctionnalites/moteur.md)), which stays with the engine and overrides
|
||||
everything. An optimizer cannot bypass a lock.
|
||||
- Every action must carry its **reason**. An action without one is rejected.
|
||||
- A malformed plan, or one that targets an unknown load, is rejected as a whole.
|
||||
|
||||
@ -19,8 +19,8 @@ pic de production prévu, garder de la marge pour la recharge du soir, etc.
|
||||
- Le moteur n'exécute que le **créneau en cours** du plan. Le reste est affiché comme
|
||||
prévision, et redemandé au cycle suivant.
|
||||
- Chaque consigne est **plafonnée** par les bornes de la charge (plancher, plafond,
|
||||
verrous anti-battement) et par la **boucle de sécurité** en temps réel, qui reste au
|
||||
moteur et prime sur tout. Un optimiseur ne peut pas contourner un verrou.
|
||||
verrous anti-battement) et par la **protection contre la surcharge** ([Comment le moteur
|
||||
décide](../fonctionnalites/moteur.md)), qui reste au moteur et prime sur tout. Un optimiseur ne peut pas contourner un verrou.
|
||||
- Chaque action doit porter son **motif**. Une action sans motif est rejetée.
|
||||
- Un plan mal formé, ou qui vise une charge inconnue, est refusé en entier.
|
||||
|
||||
|
||||