Enable energymeter interface for single and split phase meters

This commit is contained in:
Simon Stürz 2021-08-26 08:58:34 +02:00
parent 1e97ba3c50
commit 65e1fb746b

View File

@ -1,5 +1,5 @@
{ {
"description": "Energy meters measure electric power consumption/production on 3 phases. Often used as root measurements.", "description": "Energy meters measure electric power consumption/production on 1, 2 or 3 phases. Often used as root measurements.",
"extends": [ "smartmeter" ], "extends": [ "smartmeter" ],
"states": [ "states": [
{ {
@ -26,12 +26,14 @@
{ {
"name": "energyConsumedPhaseB", "name": "energyConsumedPhaseB",
"type": "double", "type": "double",
"unit": "KiloWattHour" "unit": "KiloWattHour",
"optional": true
}, },
{ {
"name": "energyConsumedPhaseC", "name": "energyConsumedPhaseC",
"type": "double", "type": "double",
"unit": "KiloWattHour" "unit": "KiloWattHour",
"optional": true
}, },
{ {
"name": "energyProducedPhaseA", "name": "energyProducedPhaseA",
@ -41,12 +43,14 @@
{ {
"name": "energyProducedPhaseB", "name": "energyProducedPhaseB",
"type": "double", "type": "double",
"unit": "KiloWattHour" "unit": "KiloWattHour",
"optional": true
}, },
{ {
"name": "energyProducedPhaseC", "name": "energyProducedPhaseC",
"type": "double", "type": "double",
"unit": "KiloWattHour" "unit": "KiloWattHour",
"optional": true
}, },
{ {
"name": "currentPowerPhaseA", "name": "currentPowerPhaseA",
@ -56,12 +60,14 @@
{ {
"name": "currentPowerPhaseB", "name": "currentPowerPhaseB",
"type": "double", "type": "double",
"unit": "Watt" "unit": "Watt",
"optional": true
}, },
{ {
"name": "currentPowerPhaseC", "name": "currentPowerPhaseC",
"type": "double", "type": "double",
"unit": "Watt" "unit": "Watt",
"optional": true
}, },
{ {
"name": "currentPhaseA", "name": "currentPhaseA",
@ -71,12 +77,14 @@
{ {
"name": "currentPhaseB", "name": "currentPhaseB",
"type": "double", "type": "double",
"unit": "Ampere" "unit": "Ampere",
"optional": true
}, },
{ {
"name": "currentPhaseC", "name": "currentPhaseC",
"type": "double", "type": "double",
"unit": "Ampere" "unit": "Ampere",
"optional": true
}, },
{ {
"name": "voltagePhaseA", "name": "voltagePhaseA",
@ -86,12 +94,14 @@
{ {
"name": "voltagePhaseB", "name": "voltagePhaseB",
"type": "double", "type": "double",
"unit": "Volt" "unit": "Volt",
"optional": true
}, },
{ {
"name": "voltagePhaseC", "name": "voltagePhaseC",
"type": "double", "type": "double",
"unit": "Volt" "unit": "Volt",
"optional": true
} }
] ]
} }