* Copyright 2013 - 2020, nymea GmbH
|
|
* Contact: contact@nymea.io
|
|
*
|
|
* This file is part of nymea.
|
|
* This project including source code and documentation is protected by
|
|
* copyright law, and remains the property of nymea GmbH. All rights, including
|
|
* reproduction, publication, editing and translation, are reserved. The use of
|
|
* this project is subject to the terms of a license agreement to be concluded
|
|
* with nymea GmbH in accordance with the terms of use of nymea GmbH, available
|
|
* under https://nymea.io/license
|
|
*
|
|
* GNU General Public License Usage
|
|
* Alternatively, this project may be redistributed and/or modified under the
|
|
* terms of the GNU General Public License as published by the Free Software
|
|
* Foundation, GNU version 3. This project is distributed in the hope that it
|
|
* will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty
|
|
* of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General
|
|
* Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License along with
|
|
* this project. If not, see <https://www.gnu.org/licenses/>.
|
|
*
|
|
* For any further details and any questions please contact us under
|
|
* contact@nymea.io or see our FAQ/Licensing Information on
|
|
* https://nymea.io/license/faq
|
|
*
|
|
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
|
|
|
|
#include "zigbeenodeinitializer.h"
|
|
#include "loggingcategories.h"
|
|
|
|
#include <zigbeenetwork.h>
|
|
|
|
Q_DECLARE_LOGGING_CATEGORY(dcZigbee)
|
|
|
|
ZigbeeNodeInitializer::ZigbeeNodeInitializer(ZigbeeNetwork *network, QObject *parent) :
|
|
QObject(parent),
|
|
m_network(network)
|
|
{
|
|
|
|
}
|
|
|
|
void ZigbeeNodeInitializer::initializeNode(ZigbeeNode *node)
|
|
{
|
|
qCDebug(dcZigbee()) << "Start initializing node internally" << node;
|
|
|
|
// Bind the coordinator to group 0x0000
|
|
//m_network->coordinatorNode()->deviceObject()->requestBindShortAddress(0x01, ZigbeeClusterLibrary::ClusterIdOnOff, 0x0000);
|
|
|
|
// Initialize and configure server clusters
|
|
foreach (ZigbeeNodeEndpoint *endpoint, node->endpoints()) {
|
|
// Configure attribute reporting
|
|
if (endpoint->hasInputCluster(ZigbeeClusterLibrary::ClusterIdPowerConfiguration)) {
|
|
|
|
// Read current battery remaining
|
|
qCDebug(dcZigbee()) << "Read power configuration cluster attributes" << node;
|
|
ZigbeeClusterReply *readAttributeReply = endpoint->getInputCluster(ZigbeeClusterLibrary::ClusterIdPowerConfiguration)->readAttributes({ZigbeeClusterPowerConfiguration::AttributeBatteryPercentageRemaining});
|
|
connect(readAttributeReply, &ZigbeeClusterReply::finished, node, [=](){
|
|
if (readAttributeReply->error() != ZigbeeClusterReply::ErrorNoError) {
|
|
qCWarning(dcZigbee()) << "Failed to read power cluster attributes" << readAttributeReply->error();
|
|
//emit nodeInitialized(node);
|
|
return;
|
|
}
|
|
qCDebug(dcZigbee()) << "Read power configuration cluster attributes finished successfully";
|
|
|
|
// Bind the cluster to the coordinator
|
|
qCDebug(dcZigbee()) << "Bind power configuration cluster to coordinaotr";
|
|
ZigbeeDeviceObjectReply * zdoReply = node->deviceObject()->requestBindIeeeAddress(endpoint->endpointId(), ZigbeeClusterLibrary::ClusterIdPowerConfiguration, m_network->coordinatorNode()->extendedAddress(), 0x01);
|
|
connect(zdoReply, &ZigbeeDeviceObjectReply::finished, node, [=](){
|
|
if (zdoReply->error() != ZigbeeDeviceObjectReply::ErrorNoError) {
|
|
qCWarning(dcZigbee()) << "Failed to bind power cluster to coordinator" << readAttributeReply->error();
|
|
return;
|
|
}
|
|
qCDebug(dcZigbee()) << "Bind power configuration cluster to coordinaotr finished successfully";
|
|
|
|
// Configure attribute rporting for battery remaining
|
|
ZigbeeClusterLibrary::AttributeReportingConfiguration reportingConfig;
|
|
reportingConfig.attributeId = ZigbeeClusterPowerConfiguration::AttributeBatteryPercentageRemaining;
|
|
reportingConfig.dataType = Zigbee::Uint8;
|
|
reportingConfig.minReportingInterval = 300;
|
|
reportingConfig.maxReportingInterval = 2700;
|
|
reportingConfig.reportableChange = ZigbeeDataType(static_cast<quint8>(14)).data();
|
|
|
|
qCDebug(dcZigbee()) << "Configure attribute reporting for power configuration cluster to coordinator";
|
|
ZigbeeClusterReply *reportingReply = endpoint->getInputCluster(ZigbeeClusterLibrary::ClusterIdPowerConfiguration)->configureReporting({reportingConfig});
|
|
connect(reportingReply, &ZigbeeClusterReply::finished, this, [reportingReply](){
|
|
if (reportingReply->error() != ZigbeeClusterReply::ErrorNoError) {
|
|
qCWarning(dcZigbee()) << "Failed to read power cluster attributes" << reportingReply->error();
|
|
return;
|
|
}
|
|
|
|
qCDebug(dcZigbee()) << "Reporting config finished" << ZigbeeClusterLibrary::parseAttributeReportingStatusRecords(reportingReply->responseFrame().payload);
|
|
});
|
|
});
|
|
});
|
|
}
|
|
}
|
|
|
|
|
|
// Initialize and configure client clusters
|
|
foreach (ZigbeeNodeEndpoint *endpoint, node->endpoints()) {
|
|
|
|
if (endpoint->hasOutputCluster(ZigbeeClusterLibrary::ClusterIdOnOff)) {
|
|
// Bind command
|
|
ZigbeeDeviceObjectReply *zdoReply = node->deviceObject()->requestBindShortAddress(endpoint->endpointId(), ZigbeeClusterLibrary::ClusterIdOnOff, m_network->coordinatorNode()->shortAddress());
|
|
connect(zdoReply, &ZigbeeDeviceObjectReply::finished, this, [zdoReply](){
|
|
if (zdoReply->error() != ZigbeeDeviceObjectReply::ErrorNoError) {
|
|
qCWarning(dcZigbee()) << "Failed to bind OnOff cluster attributes" << zdoReply->error();
|
|
return;
|
|
}
|
|
});
|
|
}
|
|
|
|
if (endpoint->hasOutputCluster(ZigbeeClusterLibrary::ClusterIdLevelControl)) {
|
|
// Bind command
|
|
ZigbeeDeviceObjectReply *zdoReply = node->deviceObject()->requestBindShortAddress(endpoint->endpointId(), ZigbeeClusterLibrary::ClusterIdLevelControl, m_network->coordinatorNode()->shortAddress());
|
|
connect(zdoReply, &ZigbeeDeviceObjectReply::finished, this, [this, node, zdoReply](){
|
|
if (zdoReply->error() != ZigbeeDeviceObjectReply::ErrorNoError) {
|
|
qCWarning(dcZigbee()) << "Failed to bind Level cluster attributes" << zdoReply->error();
|
|
//emit nodeInitialized(node);
|
|
return;
|
|
}
|
|
});
|
|
}
|
|
}
|
|
|
|
//emit nodeInitialized(node);
|
|
}
|