Enable energymeter interface for single and split phase meters

pull/459/head
Simon Stürz 2021-08-26 08:58:34 +02:00
parent 1e97ba3c50
commit 65e1fb746b
1 changed files with 21 additions and 11 deletions

View File

@ -1,5 +1,5 @@
{
"description": "Energy meters measure electric power consumption/production on 3 phases. Often used as root measurements.",
"description": "Energy meters measure electric power consumption/production on 1, 2 or 3 phases. Often used as root measurements.",
"extends": [ "smartmeter" ],
"states": [
{
@ -26,12 +26,14 @@
{
"name": "energyConsumedPhaseB",
"type": "double",
"unit": "KiloWattHour"
"unit": "KiloWattHour",
"optional": true
},
{
"name": "energyConsumedPhaseC",
"type": "double",
"unit": "KiloWattHour"
"unit": "KiloWattHour",
"optional": true
},
{
"name": "energyProducedPhaseA",
@ -41,12 +43,14 @@
{
"name": "energyProducedPhaseB",
"type": "double",
"unit": "KiloWattHour"
"unit": "KiloWattHour",
"optional": true
},
{
"name": "energyProducedPhaseC",
"type": "double",
"unit": "KiloWattHour"
"unit": "KiloWattHour",
"optional": true
},
{
"name": "currentPowerPhaseA",
@ -56,12 +60,14 @@
{
"name": "currentPowerPhaseB",
"type": "double",
"unit": "Watt"
"unit": "Watt",
"optional": true
},
{
"name": "currentPowerPhaseC",
"type": "double",
"unit": "Watt"
"unit": "Watt",
"optional": true
},
{
"name": "currentPhaseA",
@ -71,12 +77,14 @@
{
"name": "currentPhaseB",
"type": "double",
"unit": "Ampere"
"unit": "Ampere",
"optional": true
},
{
"name": "currentPhaseC",
"type": "double",
"unit": "Ampere"
"unit": "Ampere",
"optional": true
},
{
"name": "voltagePhaseA",
@ -86,12 +94,14 @@
{
"name": "voltagePhaseB",
"type": "double",
"unit": "Volt"
"unit": "Volt",
"optional": true
},
{
"name": "voltagePhaseC",
"type": "double",
"unit": "Volt"
"unit": "Volt",
"optional": true
}
]
}