126 lines
4.5 KiB
C++
126 lines
4.5 KiB
C++
/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
|
|
*
|
|
* Copyright 2013 - 2020, nymea GmbH
|
|
* Contact: contact@nymea.io
|
|
*
|
|
* This file is part of nymea-zigbee.
|
|
* This project including source code and documentation is protected by copyright law, and
|
|
* remains the property of nymea GmbH. All rights, including reproduction, publication,
|
|
* editing and translation, are reserved. The use of this project is subject to the terms of a
|
|
* license agreement to be concluded with nymea GmbH in accordance with the terms
|
|
* of use of nymea GmbH, available under https://nymea.io/license
|
|
*
|
|
* GNU Lesser General Public License Usage
|
|
* Alternatively, this project may be redistributed and/or modified under the terms of the GNU
|
|
* Lesser General Public License as published by the Free Software Foundation; version 3.
|
|
* this project is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY;
|
|
* without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
|
|
* See the GNU Lesser General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU Lesser General Public License along with this project.
|
|
* If not, see <https://www.gnu.org/licenses/>.
|
|
*
|
|
* For any further details and any questions please contact us under contact@nymea.io
|
|
* or see our FAQ/Licensing Information on https://nymea.io/license/faq
|
|
*
|
|
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
|
|
|
|
#ifndef ZIGBEECLUSTERPOWERCONFIGURATION_H
|
|
#define ZIGBEECLUSTERPOWERCONFIGURATION_H
|
|
|
|
#include <QObject>
|
|
|
|
#include "zcl/zigbeecluster.h"
|
|
|
|
class ZigbeeNode;
|
|
class ZigbeeNetwork;
|
|
class ZigbeeNodeEndpoint;
|
|
class ZigbeeNetworkReply;
|
|
|
|
class ZigbeeClusterPowerConfiguration : public ZigbeeCluster
|
|
{
|
|
Q_OBJECT
|
|
|
|
friend class ZigbeeNode;
|
|
friend class ZigbeeNetwork;
|
|
|
|
public:
|
|
enum Attribute {
|
|
// Mains information
|
|
AttributeMainsVoltage = 0x0000,
|
|
AttributeMainsFrequency = 0x0001,
|
|
|
|
// Mains settings
|
|
AttributeMainsAlarmMask = 0x0010,
|
|
AttributeMainsVoltageMinThreshold = 0x0011,
|
|
AttributeMainsVoltageMaxThreshold = 0x0012,
|
|
AttributeMainsVoltageDwellTripPoint = 0x0013,
|
|
|
|
// Battery information
|
|
AttributeBatteryVoltage = 0x0020,
|
|
AttributeBatteryPercentageRemaining = 0x0021,
|
|
|
|
// Battery settings
|
|
AttributeBatteryManufacturer = 0x0030,
|
|
AttributeBatterySize = 0x0031,
|
|
AttributeBatteryAHrRating = 0x0032,
|
|
AttributeBatteryQuality = 0x0033,
|
|
AttributeBatteryRatedVoltage = 0x0034,
|
|
AttributeBatteryAlarmMask = 0x0035,
|
|
AttributeBatteryVoltageMinThreshold = 0x0036,
|
|
AttributeBatteryVoltageThreshold1 = 0x0037,
|
|
AttributeBatteryVoltageThreshold2 = 0x0038,
|
|
AttributeBatteryVoltageThreshold3 = 0x0039,
|
|
AttributeBatteryPercentageMinThreshold = 0x003a,
|
|
AttributeBatteryPercentageThreshold1 = 0x003b,
|
|
AttributeBatteryPercentageThreshold2 = 0x003c,
|
|
AttributeBatteryPercentageThreshold3 = 0x003d,
|
|
AttributeBatteryAlarmState = 0x003e
|
|
};
|
|
Q_ENUM(Attribute)
|
|
|
|
enum MainsAlarm {
|
|
MainsAlarmNone = 0x00,
|
|
MainsAlarmMainVoltageToLow = 0x01,
|
|
MainsAlarmMainVoltageToHigh = 0x02,
|
|
MainsAlarmMainPowerSupplyLost = 0x04
|
|
};
|
|
Q_ENUM(MainsAlarm)
|
|
Q_DECLARE_FLAGS(MainsAlarmMask, MainsAlarm)
|
|
|
|
enum BatteryAlarm {
|
|
BatteryAlarmNone = 0x00,
|
|
BatteryAlarmTooLowToOperate = 0x01,
|
|
BatteryAlarm1 = 0x02,
|
|
BatteryAlarm2 = 0x04,
|
|
BatteryAlarm3 = 0x08
|
|
};
|
|
Q_ENUM(BatteryAlarm)
|
|
Q_DECLARE_FLAGS(BatteryAlarmMask, BatteryAlarm)
|
|
|
|
explicit ZigbeeClusterPowerConfiguration(ZigbeeNetwork *network, ZigbeeNode *node, ZigbeeNodeEndpoint *endpoint, Direction direction, QObject *parent = nullptr);
|
|
|
|
double batteryPercentage() const;
|
|
double batteryVoltage() const;
|
|
BatteryAlarmMask batteryAlarmState() const;
|
|
|
|
private:
|
|
double m_batteryPercentage = 0;
|
|
double m_batteryVoltage = 0;
|
|
BatteryAlarmMask m_batteryAlarmState = BatteryAlarmNone;
|
|
|
|
void setAttribute(const ZigbeeClusterAttribute &attribute) override;
|
|
|
|
signals:
|
|
void batteryPercentageChanged(double percentage);
|
|
void batteryVoltageChanged(double voltage);
|
|
void batteryAlarmStateChanged(ZigbeeClusterPowerConfiguration::BatteryAlarmMask alarmState);
|
|
|
|
};
|
|
|
|
Q_DECLARE_OPERATORS_FOR_FLAGS(ZigbeeClusterPowerConfiguration::MainsAlarmMask)
|
|
Q_DECLARE_OPERATORS_FOR_FLAGS(ZigbeeClusterPowerConfiguration::BatteryAlarmMask)
|
|
|
|
|
|
#endif // ZIGBEECLUSTERPOWERCONFIGURATION_H
|