Fronius: Set energy states to 0 if not connected
parent
bc059d4efd
commit
eadc69b4e3
|
|
@ -1,6 +1,6 @@
|
|||
/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
|
||||
*
|
||||
* Copyright 2013 - 2022, nymea GmbH
|
||||
* Copyright 2013 - 2023, nymea GmbH
|
||||
* Contact: contact@nymea.io
|
||||
*
|
||||
* This file is part of nymea.
|
||||
|
|
@ -170,7 +170,14 @@ void IntegrationPluginFronius::setupThing(ThingSetupInfo *info)
|
|||
if (!available) {
|
||||
// Update all child things, they will be set to available once the connection starts working again
|
||||
foreach (Thing *childThing, myThings().filterByParentId(thing->id())) {
|
||||
childThing->setStateValue("connected", false);
|
||||
// Reset live data states in order to show missing information by 0 line and not by keeping the last known value
|
||||
if (childThing->thingClassId() == inverterThingClassId) {
|
||||
markInverterAsDisconnected(childThing);
|
||||
} else if (childThing->thingClassId() == meterThingClassId) {
|
||||
markMeterAsDisconnected(childThing);
|
||||
} else if (childThing->thingClassId() == storageThingClassId) {
|
||||
markStorageAsDisconnected(childThing);
|
||||
}
|
||||
}
|
||||
}
|
||||
});
|
||||
|
|
@ -435,7 +442,7 @@ void IntegrationPluginFronius::updatePowerFlow(FroniusSolarConnection *connectio
|
|||
QJsonParseError error;
|
||||
QJsonDocument jsonDoc = QJsonDocument::fromJson(data, &error);
|
||||
if (error.error != QJsonParseError::NoError) {
|
||||
qCWarning(dcFronius()) << "Meter: Failed to parse JSON data" << data << ":" << error.errorString();
|
||||
qCWarning(dcFronius()) << "PowerFlow: Failed to parse JSON data" << data << ":" << error.errorString();
|
||||
return;
|
||||
}
|
||||
|
||||
|
|
@ -482,7 +489,7 @@ void IntegrationPluginFronius::updateInverters(FroniusSolarConnection *connectio
|
|||
connect(realtimeDataReply, &FroniusNetworkReply::finished, this, [=]() {
|
||||
if (realtimeDataReply->networkReply()->error() != QNetworkReply::NoError) {
|
||||
// Thing does not seem to be reachable
|
||||
inverterThing->setStateValue("connected", false);
|
||||
markInverterAsDisconnected(inverterThing);
|
||||
return;
|
||||
}
|
||||
|
||||
|
|
@ -492,7 +499,7 @@ void IntegrationPluginFronius::updateInverters(FroniusSolarConnection *connectio
|
|||
QJsonDocument jsonDoc = QJsonDocument::fromJson(data, &error);
|
||||
if (error.error != QJsonParseError::NoError) {
|
||||
qCWarning(dcFronius()) << "Inverter: Failed to parse JSON data" << data << ":" << error.errorString();
|
||||
inverterThing->setStateValue("connected", false);
|
||||
markInverterAsDisconnected(inverterThing);
|
||||
return;
|
||||
}
|
||||
|
||||
|
|
@ -546,7 +553,7 @@ void IntegrationPluginFronius::updateMeters(FroniusSolarConnection *connection)
|
|||
connect(realtimeDataReply, &FroniusNetworkReply::finished, this, [=]() {
|
||||
if (realtimeDataReply->networkReply()->error() != QNetworkReply::NoError) {
|
||||
// Thing does not seem to be reachable
|
||||
meterThing->setStateValue("connected", false);
|
||||
markMeterAsDisconnected(meterThing);
|
||||
return;
|
||||
}
|
||||
|
||||
|
|
@ -556,7 +563,7 @@ void IntegrationPluginFronius::updateMeters(FroniusSolarConnection *connection)
|
|||
QJsonDocument jsonDoc = QJsonDocument::fromJson(data, &error);
|
||||
if (error.error != QJsonParseError::NoError) {
|
||||
qCWarning(dcFronius()) << "Meter: Failed to parse JSON data" << data << ":" << error.errorString();
|
||||
meterThing->setStateValue("connected", false);
|
||||
markMeterAsDisconnected(meterThing);
|
||||
return;
|
||||
}
|
||||
|
||||
|
|
@ -637,7 +644,7 @@ void IntegrationPluginFronius::updateStorages(FroniusSolarConnection *connection
|
|||
connect(realtimeDataReply, &FroniusNetworkReply::finished, this, [=]() {
|
||||
if (realtimeDataReply->networkReply()->error() != QNetworkReply::NoError) {
|
||||
// Thing does not seem to be reachable
|
||||
storageThing->setStateValue("connected", false);
|
||||
markStorageAsDisconnected(storageThing);
|
||||
return;
|
||||
}
|
||||
|
||||
|
|
@ -646,8 +653,8 @@ void IntegrationPluginFronius::updateStorages(FroniusSolarConnection *connection
|
|||
QJsonParseError error;
|
||||
QJsonDocument jsonDoc = QJsonDocument::fromJson(data, &error);
|
||||
if (error.error != QJsonParseError::NoError) {
|
||||
qCWarning(dcFronius()) << "Meter: Failed to parse JSON data" << data << ":" << error.errorString();
|
||||
storageThing->setStateValue("connected", false);
|
||||
qCWarning(dcFronius()) << "Storage: Failed to parse JSON data" << data << ":" << error.errorString();
|
||||
markStorageAsDisconnected(storageThing);
|
||||
return;
|
||||
}
|
||||
|
||||
|
|
@ -678,3 +685,35 @@ void IntegrationPluginFronius::updateStorages(FroniusSolarConnection *connection
|
|||
});
|
||||
}
|
||||
}
|
||||
|
||||
void IntegrationPluginFronius::markInverterAsDisconnected(Thing *thing)
|
||||
{
|
||||
thing->setStateValue("connected", false);
|
||||
thing->setStateValue("currentPower", 0);
|
||||
// Note: do not reset the energy counters since they are always counting up until reset on the device
|
||||
}
|
||||
|
||||
void IntegrationPluginFronius::markMeterAsDisconnected(Thing *thing)
|
||||
{
|
||||
thing->setStateValue("connected", false);
|
||||
thing->setStateValue("currentPower", 0);
|
||||
thing->setStateValue("voltagePhaseA", 0);
|
||||
thing->setStateValue("voltagePhaseB", 0);
|
||||
thing->setStateValue("voltagePhaseC", 0);
|
||||
thing->setStateValue("currentPhaseA", 0);
|
||||
thing->setStateValue("currentPhaseB", 0);
|
||||
thing->setStateValue("currentPhaseC", 0);
|
||||
thing->setStateValue("currentPowerPhaseA", 0);
|
||||
thing->setStateValue("currentPowerPhaseB", 0);
|
||||
thing->setStateValue("currentPowerPhaseC", 0);
|
||||
thing->setStateValue("frequency", 0);
|
||||
// Note: do not reset the energy counters since they are always counting up until reset on the device
|
||||
}
|
||||
|
||||
void IntegrationPluginFronius::markStorageAsDisconnected(Thing *thing)
|
||||
{
|
||||
thing->setStateValue("connected", false);
|
||||
thing->setStateValue("currentPower", 0);
|
||||
thing->setStateValue("chargingState", "idle");
|
||||
// Note: do not reset the energy counters since they are always counting up until reset on the device
|
||||
}
|
||||
|
|
|
|||
|
|
@ -1,6 +1,6 @@
|
|||
/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
|
||||
*
|
||||
* Copyright 2013 - 2022, nymea GmbH
|
||||
* Copyright 2013 - 2023, nymea GmbH
|
||||
* Contact: contact@nymea.io
|
||||
*
|
||||
* This file is part of nymea.
|
||||
|
|
@ -68,6 +68,9 @@ private:
|
|||
void updateMeters(FroniusSolarConnection *connection);
|
||||
void updateStorages(FroniusSolarConnection *connection);
|
||||
|
||||
void markInverterAsDisconnected(Thing *thing);
|
||||
void markMeterAsDisconnected(Thing *thing);
|
||||
void markStorageAsDisconnected(Thing *thing);
|
||||
};
|
||||
|
||||
#endif // INTEGRATIONPLUGINFRONIUS_H
|
||||
|
|
|
|||
Loading…