nymea-plugins-modbus/bgetech/integrationpluginbgetech.json

231 lines
11 KiB
JSON

{
"name": "bgeTech",
"displayName": "B+G E-Tech",
"id": "e373f492-4527-4d5f-aa48-34d38c55b0d6",
"paramTypes":[ ],
"vendors": [
{
"name": "bgetech",
"displayName": "B+G E-Tech",
"id": "215035fe-95e8-43d8-a52e-0a31b787d902",
"thingClasses": [
{
"name": "sdm630",
"displayName": "SDM630",
"id": "f37597bb-35fe-48f2-9617-343dd54c0903",
"createMethods": ["discovery"],
"interfaces": ["energymeter", "connectable"],
"discoveryParamTypes": [
{
"id": "6ab43559-53ec-47ba-b8a0-8d3b7f8d90c2",
"name": "slaveAddress",
"displayName": "Slave address",
"type": "int",
"defaultValue": 1
}
],
"paramTypes": [
{
"id": "ac77ea98-b006-486e-a3e8-b30a483f26c1",
"name": "slaveAddress",
"displayName": "Modbus slave address",
"type": "uint",
"defaultValue": 1
},
{
"id": "d90e9292-d03c-4f2a-957e-5d965018c9c9",
"name": "modbusMasterUuid",
"displayName": "Modbus RTU master",
"type": "QUuid",
"defaultValue": "",
"readOnly": true
}
],
"stateTypes": [
{
"id": "8050bd0b-1dad-4a7e-b632-c71ead3c9f8b",
"name": "connected",
"displayName": "Connected",
"displayNameEvent": "Connected changed",
"type": "bool",
"cached": false,
"defaultValue": false
},
{
"id": "db018146-0441-4dc0-9834-6d43ebaf8311",
"name": "voltagePhaseA",
"displayName": "Voltage phase A",
"displayNameEvent": "Voltage phase A changed",
"type": "double",
"unit": "Volt",
"defaultValue": 0
},
{
"id": "406f6d02-d5eb-49b3-87da-3247568e6054",
"name": "voltagePhaseB",
"displayName": "Voltage phase B",
"displayNameEvent": "Voltage phase B changed",
"type": "double",
"unit": "Volt",
"defaultValue": 0
},
{
"id": "ace6294d-deaa-4d9a-af78-d64379bcb229",
"name": "voltagePhaseC",
"displayName": "Voltage phase C",
"displayNameEvent": "Voltage phase C changed",
"type": "double",
"unit": "Volt",
"defaultValue": 0
},
{
"id": "4baf1d08-5ffa-49cf-95ef-9527b0c6f081",
"name": "currentPhaseA",
"displayName": "Current phase A",
"displayNameEvent": "Current phase A changed",
"type": "double",
"unit": "Ampere",
"defaultValue": 0
},
{
"id": "99e47d06-0a6a-4bfd-b164-61ecb6ba2818",
"name": "currentPhaseB",
"displayName": "Current phase B",
"displayNameEvent": "Current phase B changed",
"type": "double",
"unit": "Ampere",
"defaultValue": 0
},
{
"id": "4a092a66-352d-4d60-90ab-6ac5f58b92fe",
"name": "currentPhaseC",
"displayName": "Current phase C",
"displayNameEvent": "Current phase C changed",
"type": "double",
"unit": "Ampere",
"defaultValue": 0
},
{
"id": "c824e97b-a6d1-4030-9d7a-00af6fb8e1c3",
"name": "currentPower",
"displayName": "Current power",
"displayNameEvent": "Current power changed",
"type": "double",
"unit": "Watt",
"defaultValue": 0
},
{
"id": "3982fb12-b179-40f7-9b27-36adb1cadd37",
"name": "currentPowerPhaseA",
"displayName": "Current power phase A",
"displayNameEvent": "Current power phase A changed",
"type": "double",
"unit": "Watt",
"defaultValue": 0
},
{
"id": "2a231c58-b095-4037-8394-a730431e70b8",
"name": "currentPowerPhaseB",
"displayName": "Current power phase B",
"displayNameEvent": "Current power phase B changed",
"type": "double",
"unit": "Watt",
"defaultValue": 0
},
{
"id": "ee8c4f0c-2b69-4210-9966-1553a592b06d",
"name": "currentPowerPhaseC",
"displayName": "Current power phase C",
"displayNameEvent": "Current power phase C changed",
"type": "double",
"unit": "Watt",
"defaultValue": 0
},
{
"id": "ab24f26c-dc15-4ec3-8d76-06a48285440b",
"name": "frequency",
"displayName": "Frequency",
"displayNameEvent": "Frequency changed",
"type": "double",
"unit": "Hertz",
"defaultValue": 0.00
},
{
"id": "98d858a8-22e8-4262-b5c7-25bb027942ad",
"name": "totalEnergyConsumed",
"displayName": "Total energy consumed",
"displayNameEvent": "Total energy consumed changed",
"type": "double",
"unit": "KiloWattHour",
"defaultValue": 0.00
},
{
"id": "e469b3ff-a4c2-42da-af35-ccafaef214af",
"name": "totalEnergyProduced",
"displayName": "Total energy produced",
"displayNameEvent": "Total energy produced changed",
"type": "double",
"unit": "KiloWattHour",
"defaultValue": 0.00
},
{
"id": "6ca06c81-fe75-4448-a22f-47c303421440",
"name": "energyConsumedPhaseA",
"displayName": "Energy consumed phase A",
"displayNameEvent": "Energy consumed phase A changed",
"type": "double",
"unit": "KiloWattHour",
"defaultValue": 0.00
},
{
"id": "fa2b879b-2a81-4bc8-9577-98082c4d9330",
"name": "energyConsumedPhaseB",
"displayName": "Energy consumed phase B",
"displayNameEvent": "Energy consumed phase B changed",
"type": "double",
"unit": "KiloWattHour",
"defaultValue": 0.00
},
{
"id": "4c084c9e-7a5d-42d1-96b2-a8a4b4a25713",
"name": "energyConsumedPhaseC",
"displayName": "Energy consumed phase C",
"displayNameEvent": "Energy consumed phase C changed",
"type": "double",
"unit": "KiloWattHour",
"defaultValue": 0.00
},
{
"id": "308fa88e-6054-4c79-b12a-be2d0a404ef6",
"name": "energyProducedPhaseA",
"displayName": "Energy produced phase A",
"displayNameEvent": "Energy produced phase A changed",
"type": "double",
"unit": "KiloWattHour",
"defaultValue": 0.00
},
{
"id": "48ab6e61-dfb4-4f85-b5cc-9d89e53c6b39",
"name": "energyProducedPhaseB",
"displayName": "Energy produced phase B",
"displayNameEvent": "Energy produced phase B changed",
"type": "double",
"unit": "KiloWattHour",
"defaultValue": 0.00
},
{
"id": "6b3ddf15-3d4b-4dc1-8e5a-84fbf90b49ff",
"name": "energyProducedPhaseC",
"displayName": "Energy produced phase C",
"displayNameEvent": "Energy produced phase C changed",
"type": "double",
"unit": "KiloWattHour",
"defaultValue": 0.00
}
]
}
]
}
]
}