162 lines
5.9 KiB
C++
162 lines
5.9 KiB
C++
// SPDX-License-Identifier: GPL-3.0-or-later
|
|
|
|
/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
|
|
*
|
|
* Copyright (C) 2013 - 2024, nymea GmbH
|
|
* Copyright (C) 2024 - 2025, chargebyte austria GmbH
|
|
*
|
|
* This file is part of nymea-plugins-modbus.
|
|
*
|
|
* nymea-plugins-modbus is free software: you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation, either version 3 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* nymea-plugins-modbus is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with nymea-plugins-modbus. If not, see <https://www.gnu.org/licenses/>.
|
|
*
|
|
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
|
|
|
|
#ifndef MTEC_H
|
|
#define MTEC_H
|
|
|
|
#include <QDateTime>
|
|
#include <QObject>
|
|
|
|
#include <modbustcpmaster.h>
|
|
|
|
class MTec : public QObject
|
|
{
|
|
Q_OBJECT
|
|
public:
|
|
enum HeatpumpState {
|
|
HeatpumpStateStandby = 0,
|
|
HeatpumpStatePreRun = 1,
|
|
HeatpumpStateAutomaticHeat = 2,
|
|
HeatpumpStateDefrost = 3,
|
|
HeatpumpStateAutomaticCool = 4,
|
|
HeatpumpStatePostRun = 5,
|
|
HeatpumpStateSaftyShutdown = 7,
|
|
HeatpumpStateError = 8
|
|
};
|
|
Q_ENUM(HeatpumpState)
|
|
|
|
explicit MTec(const QHostAddress &address, QObject *parent = nullptr);
|
|
~MTec();
|
|
|
|
ModbusTcpMaster *modbusTcpMaster() const;
|
|
|
|
QHostAddress hostAddress() const;
|
|
|
|
bool connected() const;
|
|
|
|
QModbusReply *setTargetRoomTemperature(double targetRoomTemperature);
|
|
QModbusReply *setSmartHomeEnergy(quint16 smartHomeEnergy);
|
|
|
|
public slots:
|
|
bool connectDevice();
|
|
void disconnectDevice();
|
|
|
|
void updateValues();
|
|
|
|
private:
|
|
/** Modbus Unit ID (undocumented, guessing 1 for now) */
|
|
static const quint16 ModbusUnitID = 1;
|
|
|
|
/** The following modbus addresses can be read: */
|
|
enum Register {
|
|
/* R APPL.CtrlAppl.sParam.heatCircuit[0].tempRoom.values.actValue
|
|
* Actual room temperature [1/10°C]. */
|
|
RegisterRoomTemperature = 1,
|
|
|
|
/* RW APPL.CtrlAppl.sParam.heatCircuit[0].param.normalSetTemp
|
|
* Room set temperature for heating circuit [1/10°C]. */
|
|
RegisterTargetRoomTemperature = 4,
|
|
|
|
/* R APPL.CtrlAppl.sParam.hotWaterTank[0].topTemp.values.actValue
|
|
* Hot water tank top temperature [1/10°C]. */
|
|
RegisterHotWaterTankTemperature = 401,
|
|
|
|
/* R APPL.CtrlAppl.sParam.bufferTank[0].topTemp.values.actValue
|
|
* Buffer Actual top temperature [1/10°C]. */
|
|
RegisterBufferTankTemperature = 601,
|
|
|
|
/* R APPL.CtrlAppl.sStatisticalData.heatpump[0].consumption.energy
|
|
* Total accumulated heating energy [kWh] */
|
|
RegisterTotalAccumulatedHeatingEnergy = 701,
|
|
|
|
/* R APPL.CtrlAppl.sStatisticalData.heatpump[0].consumption.electricalenergy
|
|
* Total accumulated electrical energy [kWh] */
|
|
RegisterTotalAccumulatedElectricalEnergy = 702,
|
|
|
|
/* R APPL.CtrlAppl.sParam.heatpump[0].values.heatpumpState */
|
|
RegisterHeatpumpState = 703,
|
|
|
|
/* R APPL.CtrlAppl.sParam.heatpump[0].HeatMeter.values.power
|
|
* Actual power consumtion [W] */
|
|
RegisterHeatMeterPowerConsumption = 706,
|
|
|
|
/* R APPL.CtrlAppl.sParam.heatpump[0].ElectricEnergyMeter.values.power
|
|
* Actual power consumtion [W] */
|
|
RegisterEnergyMeterPowerConsumption = 707,
|
|
|
|
/* RW APPL.CtrlAppl.sIOModule.Virt[0].param.sensor[0]
|
|
* Acutal excess energy given from Smart home System [W] */
|
|
RegisterActualExcessEnergySmartHome = 1000,
|
|
|
|
/* R APPL.CtrlAppl.sParam.photovoltaics.ElectricEnergyMeter.values.power
|
|
* Acutal excess energy given from Electricity Meter [W] */
|
|
RegisterActualExcessEnergySmartHomeElectricityMeter = 1002,
|
|
|
|
/* R APPL.CtrlAppl.sParam.outdoorTemp.values.actValue
|
|
* Actual exterior temperature [°C] */
|
|
RegisterActualOutdoorTemperature = 1502,
|
|
|
|
};
|
|
|
|
QHostAddress m_hostAddress;
|
|
ModbusTcpMaster *m_modbusMaster = nullptr;
|
|
|
|
double m_roomTemperature = 0;
|
|
double m_targetRoomTemperature = 0;
|
|
double m_waterTankTopTemperature = 0;
|
|
double m_bufferTankTemperature = 0;
|
|
double m_totalAccumulatedHeatingEnergy = 0;
|
|
double m_totalAccumulatedElectricalEnergy = 0;
|
|
HeatpumpState m_heatPumpState = HeatpumpStateStandby;
|
|
double m_heatMeterPowerConsumption = 0;
|
|
double m_energyMeterPowerConsumption = 0;
|
|
double m_actualExcessEnergySmartHome = 0;
|
|
double m_actualExcessEnergySmartHomeElectricityMeter = 0;
|
|
double m_actualOutdoorTemperature = 0;
|
|
|
|
signals:
|
|
void connectedChanged(bool connected);
|
|
|
|
void roomTemperatureChanged(double roomTemperature);
|
|
void targetRoomTemperatureChanged(double targetRoomTemperature);
|
|
void waterTankTopTemperatureChanged(double waterTankTopTemperature);
|
|
void bufferTankTemperatureChanged(double bufferTankTemperature);
|
|
void totalAccumulatedHeatingEnergyChanged(double totalAccumulatedHeatingEnergy);
|
|
void totalAccumulatedElectricalEnergyChanged(double totalAccumulatedElectricalEnergy);
|
|
void heatPumpStateChanged(HeatpumpState heatPumpState);
|
|
void heatMeterPowerConsumptionChanged(double heatMeterPowerConsumption);
|
|
void energyMeterPowerConsumptionChanged(double energyMeterPowerConsumption);
|
|
void actualExcessEnergySmartHomeChanged(double actualExcessEnergySmartHome);
|
|
void actualExcessEnergySmartHomeElectricityMeterChanged(double actualExcessEnergySmartHomeElectricityMeter);
|
|
void actualOutdoorTemperatureChanged(double actualOutdoorTemperature);
|
|
|
|
private slots:
|
|
void onModbusError();
|
|
void onReceivedHoldingRegister(int slaveAddress, int modbusRegister, const QVector<quint16> &value);
|
|
|
|
};
|
|
|
|
#endif // MTEC_H
|
|
|