nymea-plugins-modbus/mennekes
Simon Stürz c525b33d44 Mennekes: Update EV charger interface and add full charging current resolution 2026-01-07 16:40:39 +01:00
..
translations Mennekes: Update translations and allow IP based connections 2024-07-03 09:14:12 +02:00
ECU_modbus_tcp_server_spec_rev_1.07.pdf Mennekes: Add support for Mennekes ECU with firmware older than 5.22 2023-11-21 15:05:11 +01:00
ModbusRTU_AmtronCompact2-0s_Description_v1-2.pdf Mennekes: Add support for the Amtron Compact 2.0s 2023-05-16 12:52:39 +02:00
Modbus_AMTRON HCC3_v01_2021-06-25_en.pdf New plugin: Mennekes HCC3 and ECU wallboxes 2022-10-20 15:42:01 +02:00
Modbus_AMTRON_ACU_modbus_tcp_server_spec_rev_1.07.pdf New plugin: Mennekes HCC3 and ECU wallboxes 2022-10-20 15:42:01 +02:00
README.md Mennekes: Add support for Mennekes ECU with firmware older than 5.22 2023-11-21 15:05:11 +01:00
amtron-compact20-registers.json Mennekes: Add support for the Amtron Compact 2.0s 2023-05-16 12:52:39 +02:00
amtron-ecu-registers.json Mennekes: Add support for Mennekes ECU with firmware older than 5.22 2023-11-21 15:05:11 +01:00
amtron-hcc3-registers.json Mennekes: Finish HCC3 controller implementation 2023-04-06 11:33:36 +02:00
amtroncompact20discovery.cpp Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
amtroncompact20discovery.h Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
amtronecu.cpp Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
amtronecu.h Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
amtronecudiscovery.cpp Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
amtronecudiscovery.h Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
amtronhcc3discovery.cpp Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
amtronhcc3discovery.h Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
integrationpluginmennekes.cpp Mennekes: Update EV charger interface and add full charging current resolution 2026-01-07 16:40:39 +01:00
integrationpluginmennekes.h Update license text and add SPDX identifier 2025-11-18 12:02:13 +01:00
integrationpluginmennekes.json Mennekes: Update EV charger interface and add full charging current resolution 2026-01-07 16:40:39 +01:00
mennekes.pro Mennekes: Add support for Mennekes ECU with firmware older than 5.22 2023-11-21 15:05:11 +01:00
mennekes.svg New plugin: Mennekes HCC3 and ECU wallboxes 2022-10-20 15:42:01 +02:00
meta.json New plugin: Mennekes HCC3 and ECU wallboxes 2022-10-20 15:42:01 +02:00

README.md

MENNEKES

Connects nymea to a MENNEKES wallboxes. Currently supported models are:

  • AMTRON Xtra
  • AMTRON Premium
  • AMTRON Professional
  • AMTRON Charge Control
  • Amedio Professional
  • AMTRON Compact 2.0s

Requirements

nymea uses the Modbus RTU (AMTRON Compact 2.0s) or Modbus TCP (all other models) connection to connect to the wallbox.

The Modbus TCP connection needs to be enabled manually on the Wallbox.

For the Amtron Charge Control and Premium models, log in to the wallbox's web interface as operator. The login credentials can be obtained from the user manual of the wallbox. Once logged in, navigate to the Load Management tab and set the Modbus TCP Server to On.

Note: Amtron Charge Control and Premium models also support firmware version 5.12 since the latest version is not complient with the calibration law.

For the AMTRON Compact 2.0s, DIP switch 4 and 5 on Bank 51 must be set to ON in order to allow nymea controlling the wallbox. With this DIP switch configuration, the solar charging mode will merely control the LED display of the wallbox.