# Modbus Commander A nymea integration plugin to send Modbus RTU or TCP requests. ## Usage Set up one Modbus RTU or TCP client first. Afterwards a register **thing** can be set-up and during the setup process the modbus client can be selected. ## Supported Things * Modbus TCP client * Modbus TCP interface * IP Address and Port of the target device are requried. * Modbus RTU client * Modbus RTU interface * All available serial ports will be discovered. * Baudrate, data bits, stop bits and parity are required. * Coil * Writes and reads a single Modbus Coil * Modbus device- and register address are required. * Discrete input * Reads a single Modbus discrete input * Modbus device- and register address are required. * Input register * Reads a single Modbus input register * Modbus device- and register address are required. * Holding register * Writes and reads a single Modbus holding register * Modbus device- and register address are required. ## Requirements * The package 'nymea-plugin-modbuscommander' must be installed. * For Modbus RTU, a serial port must be available. * For Modbus TCP, the target deviecc must be in the same network. ## Settings ### Plug-In Configuration *Update interval* Defines the interval for register polling in seconds. Minimum and default value is 1 second. ### Modbus TCP & RTU Client Settings *Timeout* Default value is 100 ms, the minimum timeout is 10 ms. The timeout is used by the Modbus client to determine how long it waits for a response from the server. The request failes if the response is not received within the given timeout. *Number of retries* Sets the number of retries a client will perform before a request fails. The default value is set to 3. ## More http://www.modbus.org/