# Amperfied - Heidelberg Connects nymea to a Amperfied/Heidelberg wallboxes. Currently supported models are: * Amperfied Energy Control * Amperfied connect.home * Amperfied connect.solar * Amperfied connect.business # Requirements nymea requires the use of a firmware greator or equal version 1.0.7 on the wallbox. ## Amperfied Energy Control The Amperfied Energy Control is a Modbus RTU device. This means it must be connected to the nymea system using an RS485 port. The Modbus RTU must be configured with a baud rate of 19200, even parity, 8 data bits and 1 stop bit. In order to allow nymea to automatically discover the wallbox on the bus, the Modbus slave ID must be in the range of 1 - 20. If a higher slave ID number is required, the manual setup is to be used. ## Amperfied connect.home/solar/business The Amperfied connect.home is a Modbus TCP device. This means it must be connected to the same network the nymea system is in.