Simon Stürz
fdee0d6453
Update discovery to renamed network device
2021-06-28 18:42:55 +02:00
Simon Stürz
6651121030
Extend modbus tcp class
2021-06-28 14:39:18 +02:00
Simon Stürz
a71b86f82e
Fix modbus tcp master code errors from rebase
2021-06-27 17:28:25 +02:00
Hermann Detz
621c98369e
Added initial version of M-Tec heatpump plugin
...
Currently only read functionality.
Not yet tested with actual hardware.
2021-06-27 17:28:25 +02:00
Simon Stürz
a62032ae45
Improve reconnect behaviour
2021-06-27 17:28:25 +02:00
Simon Stürz
f8bc078437
Extend modbus tcp class
2021-06-27 17:28:25 +02:00
Boernsman
4d5911a098
switched to modbus rtu resource
2021-06-27 17:27:15 +02:00
Boernsman
7fed767ff1
added modbusTcp error method
2021-06-27 17:24:38 +02:00
Boernsman
4c1ec41a15
added set target temperature action
2021-06-27 17:24:38 +02:00
Boernsman
f004899127
changed interface, fixed remarks from reviewer
2021-06-27 17:24:38 +02:00
Boernsman
ccdb0c371f
fixed wrong modbus tcp signals
2021-06-27 17:24:38 +02:00
Hermann Detz
2c342bc658
Added functionality to set target room temp
2021-06-27 17:24:38 +02:00
Hermann Detz
375b7a9d5d
Added humidity and connected state
...
ModbusTCPMaster now emits readRequestError and writeRequestError, which
trigger connected = false.
2021-06-27 17:24:38 +02:00
Hermann Detz
ad70d1d254
Fixes for Idm plugin
...
Hopefully reading room temperature and outside temperature correctly
now.
2021-06-27 17:24:38 +02:00
Hermann Detz
bd5f3be35d
Helper functions to convert modbus reg to float
2021-06-27 17:24:38 +02:00
Simon Stürz
352413563f
Use new modbus RTU hardware resource for the modbus commander plugin
...
Use new modbus RTU hardware resource for the modbus commander plugin
Fix action abort for RTU actions and fix connected state fro child RTU things
Fix modbus rtu client and make it work with the basic resource component
Remove modbusrtu master from project file
Remove custom modbus rtu master include
2021-06-27 17:22:41 +02:00
Boernsman
71e51e8337
fixed wallbe plugin
2021-02-22 20:31:44 +01:00
Boernsman
0a57de310c
stop sending read requests if the interface is not connected
2020-12-07 22:06:05 +01:00
Boernsman
78055fbdf5
fixed typos and extended readme
2020-12-07 21:52:56 +01:00
Boernsman
e8a5cfb228
added number of retries and timeout settings
2020-12-02 11:43:45 +01:00
Boernsman
c73248048c
improved RTU client setup
2020-12-02 09:37:57 +01:00
Michael Zanetti
0b0955f050
Fix logging categories
2020-10-22 22:12:00 +02:00
Boernsman
68e38a1eaf
fixed Fronius plug-in
2020-06-17 16:16:35 +02:00
Boernsman
bdbb239c59
changed fronius to make use of QModbus
2020-06-17 13:34:05 +02:00
Boernsman
05e71c24f6
moved mypv to QModbus
2020-06-16 17:32:42 +02:00
Boernsman
bd6cfd8b02
added modbus abstaction class
2020-06-16 16:56:20 +02:00