Commit Graph

26 Commits (cd60c171ebef4a309565ce26c8593f6251b9de4e)

Author SHA1 Message Date
Simon Stürz fdee0d6453 Update discovery to renamed network device 2021-06-28 18:42:55 +02:00
Simon Stürz 6651121030 Extend modbus tcp class 2021-06-28 14:39:18 +02:00
Simon Stürz a71b86f82e Fix modbus tcp master code errors from rebase 2021-06-27 17:28:25 +02:00
Hermann Detz 621c98369e Added initial version of M-Tec heatpump plugin
Currently only read functionality.
Not yet tested with actual hardware.
2021-06-27 17:28:25 +02:00
Simon Stürz a62032ae45 Improve reconnect behaviour 2021-06-27 17:28:25 +02:00
Simon Stürz f8bc078437 Extend modbus tcp class 2021-06-27 17:28:25 +02:00
Boernsman 4d5911a098 switched to modbus rtu resource 2021-06-27 17:27:15 +02:00
Boernsman 7fed767ff1 added modbusTcp error method 2021-06-27 17:24:38 +02:00
Boernsman 4c1ec41a15 added set target temperature action 2021-06-27 17:24:38 +02:00
Boernsman f004899127 changed interface, fixed remarks from reviewer 2021-06-27 17:24:38 +02:00
Boernsman ccdb0c371f fixed wrong modbus tcp signals 2021-06-27 17:24:38 +02:00
Hermann Detz 2c342bc658 Added functionality to set target room temp 2021-06-27 17:24:38 +02:00
Hermann Detz 375b7a9d5d Added humidity and connected state
ModbusTCPMaster now emits readRequestError and writeRequestError, which
trigger connected = false.
2021-06-27 17:24:38 +02:00
Hermann Detz ad70d1d254 Fixes for Idm plugin
Hopefully reading room temperature and outside temperature correctly
now.
2021-06-27 17:24:38 +02:00
Hermann Detz bd5f3be35d Helper functions to convert modbus reg to float 2021-06-27 17:24:38 +02:00
Simon Stürz 352413563f Use new modbus RTU hardware resource for the modbus commander plugin
Use new modbus RTU hardware resource for the modbus commander plugin

Fix action abort for RTU actions and fix connected state fro child RTU things

Fix modbus rtu client and make it work with the basic resource component

Remove modbusrtu master from project file

Remove custom modbus rtu master include
2021-06-27 17:22:41 +02:00
Boernsman 71e51e8337 fixed wallbe plugin 2021-02-22 20:31:44 +01:00
Boernsman 0a57de310c stop sending read requests if the interface is not connected 2020-12-07 22:06:05 +01:00
Boernsman 78055fbdf5 fixed typos and extended readme 2020-12-07 21:52:56 +01:00
Boernsman e8a5cfb228 added number of retries and timeout settings 2020-12-02 11:43:45 +01:00
Boernsman c73248048c improved RTU client setup 2020-12-02 09:37:57 +01:00
Michael Zanetti 0b0955f050 Fix logging categories 2020-10-22 22:12:00 +02:00
Boernsman 68e38a1eaf fixed Fronius plug-in 2020-06-17 16:16:35 +02:00
Boernsman bdbb239c59 changed fronius to make use of QModbus 2020-06-17 13:34:05 +02:00
Boernsman 05e71c24f6 moved mypv to QModbus 2020-06-16 17:32:42 +02:00
Boernsman bd6cfd8b02 added modbus abstaction class 2020-06-16 16:56:20 +02:00