Merge PR #216: Wattsonic: Improve inverter generation detection and provide fallback mechanism
commit
c8eeeac911
|
|
@ -157,7 +157,17 @@ void IntegrationPluginWattsonic::setupWattsonicConnection(ThingSetupInfo *info)
|
|||
return;
|
||||
}
|
||||
|
||||
WattsonicInverter *connection = new WattsonicInverter(hardwareManager()->modbusRtuResource()->getModbusRtuMaster(uuid), slaveId, this);
|
||||
QString inverterGenerationModeString = thing->paramValue(inverterThingInverterGenerationParamTypeId).toString();
|
||||
WattsonicInverter::InverterGenerationMode inverterGenerationMode;
|
||||
if (inverterGenerationModeString == "Gen2") {
|
||||
inverterGenerationMode = WattsonicInverter::InverterGenerationModeGen2;
|
||||
} else if (inverterGenerationModeString == "Gen3") {
|
||||
inverterGenerationMode = WattsonicInverter::InverterGenerationModeGen3;
|
||||
} else {
|
||||
inverterGenerationMode = WattsonicInverter::InverterGenerationModeAuto;
|
||||
}
|
||||
|
||||
WattsonicInverter *connection = new WattsonicInverter(hardwareManager()->modbusRtuResource()->getModbusRtuMaster(uuid), slaveId, inverterGenerationMode, this);
|
||||
m_connections.insert(thing, connection);
|
||||
|
||||
// Only for setup
|
||||
|
|
|
|||
|
|
@ -44,6 +44,14 @@
|
|||
"displayName": "Serial number",
|
||||
"type": "QString",
|
||||
"defaultValue": ""
|
||||
},
|
||||
{
|
||||
"id": "388032f7-80c6-4410-8f7b-367cd06cb40a",
|
||||
"name": "inverterGeneration",
|
||||
"displayName": "Inverter generation",
|
||||
"type": "QString",
|
||||
"allowedValues": ["Auto", "Gen2", "Gen3"],
|
||||
"defaultValue": "Auto"
|
||||
}
|
||||
],
|
||||
"stateTypes": [
|
||||
|
|
|
|||
|
|
@ -77,7 +77,7 @@ void WattsonicDiscovery::tryConnect(ModbusRtuMaster *master, quint16 slaveId)
|
|||
qCDebug(dcWattsonic()) << "Discovery: Scanning modbus RTU master" << master->modbusUuid() << "Slave ID:" << slaveId;
|
||||
m_verifiedMasters.append(master);
|
||||
|
||||
WattsonicInverter *connection = new WattsonicInverter(master, slaveId, this);
|
||||
WattsonicInverter *connection = new WattsonicInverter(master, slaveId, WattsonicInverter::InverterGenerationModeAuto, this);
|
||||
connect(connection, &WattsonicInverter::reachableChanged, this, [connection](bool reachable){
|
||||
if (reachable) {
|
||||
qCDebug(dcWattsonic()) << "Discovery: The connection is now reachable. Starting the initialization";
|
||||
|
|
|
|||
|
|
@ -29,12 +29,14 @@
|
|||
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
|
||||
|
||||
#include "wattsonicinverter.h"
|
||||
#include "extern-plugininfo.h"
|
||||
|
||||
#include <QLoggingCategory>
|
||||
Q_DECLARE_LOGGING_CATEGORY(dcWattsonicModbusRtuConnection)
|
||||
|
||||
WattsonicInverter::WattsonicInverter(ModbusRtuMaster *modbusRtuMaster, quint16 slaveId, QObject *parent)
|
||||
: WattsonicModbusRtuConnection{modbusRtuMaster, slaveId, parent}
|
||||
WattsonicInverter::WattsonicInverter(ModbusRtuMaster *modbusRtuMaster, quint16 slaveId, InverterGenerationMode generationMode, QObject *parent)
|
||||
: WattsonicModbusRtuConnection{modbusRtuMaster, slaveId, parent},
|
||||
m_generationMode{generationMode}
|
||||
{
|
||||
connect(this, &WattsonicInverter::initializationFinished, this, [this](bool success){
|
||||
|
||||
|
|
@ -58,26 +60,43 @@ WattsonicInverter::WattsonicInverter(ModbusRtuMaster *modbusRtuMaster, quint16 s
|
|||
qCDebug(dcWattsonicModbusRtuConnection()) << "Internal init finished successfully" << serialNumber() << inverterInfo.type << inverterInfo.model;
|
||||
m_inverterInfo = inverterInfo;
|
||||
|
||||
// Verify which generation this is by testing one generation dependent register.
|
||||
ModbusRtuReply *reply = readBatteryVoltageDcGen2();
|
||||
if (!reply) {
|
||||
qCWarning(dcWattsonicModbusRtuConnection()) << "Unable to test the generation request on the modbus master. Something might be wrong with the connection.";
|
||||
emit customInitializationFinished(false);
|
||||
return;
|
||||
if (m_generationMode == InverterGenerationModeAuto) {
|
||||
|
||||
// Verify which generation this is by testing one generation dependent register.
|
||||
// On Gen3 this request returns with an exception response
|
||||
|
||||
// Note: The DC voltage returns in both generations valid data, don't use that one
|
||||
qCDebug(dcWattsonic()) << "Inverter generation autodetection active. Checking the inverter generation...";
|
||||
ModbusRtuReply *reply = readSOCGen2();
|
||||
if (!reply) {
|
||||
qCWarning(dcWattsonicModbusRtuConnection()) << "Unable to test the generation request on the modbus master. Something might be wrong with the connection.";
|
||||
emit customInitializationFinished(false);
|
||||
return;
|
||||
}
|
||||
|
||||
connect(reply, &ModbusRtuReply::finished, this, [this, reply](){
|
||||
if (reply->error() != ModbusRtuReply::NoError) {
|
||||
qCWarning(dcWattsonicModbusRtuConnection()) << "Reply finished with error after reading a Gen2 register. Assuming this is a Gen3 inverter.";
|
||||
m_generation = Generation3;
|
||||
emit customInitializationFinished(true);
|
||||
return;
|
||||
} else {
|
||||
qCDebug(dcWattsonicModbusRtuConnection()) << "Successfully read gen2 register. Assuming this is a Gen2 inverter.";
|
||||
m_generation = Generation2;
|
||||
emit customInitializationFinished(true);
|
||||
}
|
||||
});
|
||||
} else {
|
||||
if (m_generationMode == InverterGenerationModeGen2) {
|
||||
m_generation = Generation2;
|
||||
} else {
|
||||
m_generation = Generation3;
|
||||
}
|
||||
|
||||
emit customInitializationFinished(true);
|
||||
qCDebug(dcWattsonic()) << "Inverter generation forced to" << m_generation;
|
||||
}
|
||||
|
||||
connect(reply, &ModbusRtuReply::finished, this, [this, reply](){
|
||||
if (reply->error() != ModbusRtuReply::NoError) {
|
||||
qCWarning(dcWattsonicModbusRtuConnection()) << "Reply finished with error after reading gen 2 register. Assuming this is a gen 3 device.";
|
||||
m_generation = Generation3;
|
||||
emit customInitializationFinished(true);
|
||||
return;
|
||||
} else {
|
||||
qCDebug(dcWattsonicModbusRtuConnection()) << "Successfully read gen2 register. Assuming this is a gen 2 device.";
|
||||
m_generation = Generation2;
|
||||
emit customInitializationFinished(true);
|
||||
}
|
||||
});
|
||||
});
|
||||
}
|
||||
|
||||
|
|
@ -163,7 +182,7 @@ float WattsonicInverter::SOH() const
|
|||
|
||||
bool WattsonicInverter::update()
|
||||
{
|
||||
if (m_generation == GenerationUnknwon) {
|
||||
if (m_generation == GenerationUnknown) {
|
||||
qCDebug(dcWattsonicModbusRtuConnection()) << "Tried to update but we don't know yet if this is a gen2 or gen3 inverter. Waiting for the information.";
|
||||
return false;
|
||||
}
|
||||
|
|
|
|||
|
|
@ -44,14 +44,21 @@ public:
|
|||
QString model;
|
||||
};
|
||||
|
||||
enum InverterGenerationMode {
|
||||
InverterGenerationModeAuto,
|
||||
InverterGenerationModeGen2,
|
||||
InverterGenerationModeGen3
|
||||
};
|
||||
Q_ENUM(InverterGenerationMode)
|
||||
|
||||
enum Generation {
|
||||
GenerationUnknwon,
|
||||
GenerationUnknown,
|
||||
Generation2,
|
||||
Generation3
|
||||
};
|
||||
Q_ENUM(Generation)
|
||||
|
||||
explicit WattsonicInverter(ModbusRtuMaster *modbusRtuMaster, quint16 slaveId, QObject *parent = nullptr);
|
||||
explicit WattsonicInverter(ModbusRtuMaster *modbusRtuMaster, quint16 slaveId, InverterGenerationMode generationMode = InverterGenerationModeAuto, QObject *parent = nullptr);
|
||||
|
||||
Generation generation() const;
|
||||
WattsonicInverter::Info inverterInfo() const;
|
||||
|
|
@ -75,7 +82,8 @@ signals:
|
|||
|
||||
private:
|
||||
WattsonicInverter::Info m_inverterInfo;
|
||||
Generation m_generation = GenerationUnknwon;
|
||||
InverterGenerationMode m_generationMode = InverterGenerationModeAuto;
|
||||
Generation m_generation = GenerationUnknown;
|
||||
|
||||
};
|
||||
|
||||
|
|
|
|||
Loading…