added operating mode description
parent
8fb4cda64c
commit
9c38777272
|
|
@ -251,6 +251,12 @@ void IntegrationPluginGenericThings::setupThing(ThingSetupInfo *info)
|
|||
thermostatCheckPowerOutputState(thing);
|
||||
}
|
||||
});
|
||||
} else if (thing->thingClassId() == sgReadyThingClassId) {
|
||||
bool relay1 = thing->stateValue(sgReadyRelay1StateTypeId).toBool();
|
||||
bool relay2 = thing->stateValue(sgReadyRelay2StateTypeId).toBool();
|
||||
int operatingMode = sgReadyOperatingMode(relay1, relay2);
|
||||
thing->setStateValue(sgReadyOperatingModeStateTypeId, operatingMode);
|
||||
thing->setStateValue(sgReadyOperatingModeDescriptionStateTypeId, sgReadyOperatingModeDescription(operatingMode));
|
||||
}
|
||||
info->finish(Thing::ThingErrorNoError);
|
||||
}
|
||||
|
|
@ -671,17 +677,17 @@ void IntegrationPluginGenericThings::executeAction(ThingActionInfo *info)
|
|||
thing->setStateValue(sgReadyOperatingModeStateTypeId, operatingMode);
|
||||
thing->setStateValue(sgReadyOperatingModeDescriptionStateTypeId, sgReadyOperatingModeDescription(operatingMode));
|
||||
if (operatingMode == 1) {
|
||||
thing->setStateValue(sgReadyRelay1StateTypeId, 1);
|
||||
thing->setStateValue(sgReadyRelay2StateTypeId, 0);
|
||||
thing->setStateValue(sgReadyRelay1StateTypeId, true);
|
||||
thing->setStateValue(sgReadyRelay2StateTypeId, false);
|
||||
} else if (operatingMode == 2) {
|
||||
thing->setStateValue(sgReadyRelay1StateTypeId, 0);
|
||||
thing->setStateValue(sgReadyRelay2StateTypeId, 0);
|
||||
thing->setStateValue(sgReadyRelay1StateTypeId, false);
|
||||
thing->setStateValue(sgReadyRelay2StateTypeId, false);
|
||||
} else if (operatingMode == 3) {
|
||||
thing->setStateValue(sgReadyRelay1StateTypeId, 0);
|
||||
thing->setStateValue(sgReadyRelay2StateTypeId, 1);
|
||||
thing->setStateValue(sgReadyRelay1StateTypeId, false);
|
||||
thing->setStateValue(sgReadyRelay2StateTypeId, true);
|
||||
} else if (operatingMode == 4) {
|
||||
thing->setStateValue(sgReadyRelay1StateTypeId, 1);
|
||||
thing->setStateValue(sgReadyRelay2StateTypeId, 1);
|
||||
thing->setStateValue(sgReadyRelay1StateTypeId, true);
|
||||
thing->setStateValue(sgReadyRelay2StateTypeId, true);
|
||||
}
|
||||
info->finish(Thing::ThingErrorNoError);
|
||||
return;
|
||||
|
|
@ -860,13 +866,13 @@ void IntegrationPluginGenericThings::thermostatCheckPowerOutputState(Thing *thin
|
|||
QString IntegrationPluginGenericThings::sgReadyOperatingModeDescription(int operatingMode)
|
||||
{
|
||||
if (operatingMode == 1) {
|
||||
return "Operating mode 1";
|
||||
return "Stop heating.";
|
||||
} else if (operatingMode == 2) {
|
||||
return "Operating mode 2";
|
||||
return "Normal mode, with partial heat storage filling.";
|
||||
} else if (operatingMode == 3) {
|
||||
return "Operating mode 3";
|
||||
return "Increased room and heat storage temperature.";
|
||||
} else if (operatingMode == 4) {
|
||||
return "Operating mode 4";
|
||||
return "Start heating.";
|
||||
}
|
||||
return QString("Unknown operating mode %1").arg(operatingMode);
|
||||
}
|
||||
|
|
@ -875,33 +881,33 @@ int IntegrationPluginGenericThings::sgReadyOperatingMode(bool relay1, bool relay
|
|||
{
|
||||
if (relay1 && !relay2) {
|
||||
/*
|
||||
* Betriebszustand 1 (1 Schaltzustand, bei Klemmenlösung: 1:0):
|
||||
* Dieser Betriebszustand ist abwärtskompatibel zur häufig zu festen Uhrzeiten
|
||||
* geschalteten EVU-Sperre und umfasst maximal 2 Stunden „harte“ Sperrzeit.
|
||||
* Operating state 1 (Relay state: 1: 0):
|
||||
* This operating state is downward compatible with the often fixed times
|
||||
* activated EVU lock and includes a maximum of 2 hours of "hard" lock time.
|
||||
*/
|
||||
return 1;
|
||||
} else if (!relay1 && !relay2) {
|
||||
/*
|
||||
* Betriebszustand 2 (1 Schaltzustand, bei Klemmenlösungen: 0:0):
|
||||
* In dieser Schaltung läuft die Wärmepumpe im energieffizienten Normalbetrieb
|
||||
* mit anteiliger Wärmespeicher-Füllung für die maximal zweistündige EVU-Sperre.
|
||||
* Operating state 2 (Relay state: 0: 0):
|
||||
* In this circuit, the heat pump runs in energy-efficient normal mode
|
||||
* with partial heat storage filling for the maximum two-hour EVU lock.
|
||||
*/
|
||||
return 2;
|
||||
} else if (!relay1 && relay2) {
|
||||
/*
|
||||
* Betriebszustand 3 (1 Schaltzustand, bei Klemmenlösung 0:1):
|
||||
* In diesem Betriebszustand läuft die Wärmepumpe innerhalb des Reglers im verstärkten
|
||||
* Betrieb für Raumheizung und Warmwasserbereitung. Es handelt sich dabei nicht um einen
|
||||
* definitiven Anlaufbefehl, sondern um eine Einschaltempfehlung entsprechend der heutigen Anhebung.
|
||||
* Operating state 3 (Relay state: 0: 1):
|
||||
* In this operating state, the heat pump within the controller runs in amplified mode
|
||||
* Operation for space heating and hot water preparation. It's not one
|
||||
* definitive start-up command, but a switch-on recommendation according to the current increase.
|
||||
*/
|
||||
return 3;
|
||||
} else {
|
||||
/*
|
||||
* Betriebszustand 4 (1 Schaltzustand, bei Klemmenlösung 1:1):
|
||||
* Hierbei handelt es sich um einen definitiven Anlaufbefehl, insofern dieser im Rahmen der Regeleinstellungen möglich ist.
|
||||
* Für diesen Betriebszustand müssen für verschiedene Tarif- und Nutzungsmodelle verschiedene Regelungsmodelle am Regler einstellbar sein:
|
||||
* Variante 1: Die Wärmepumpe (Verdichter) wird aktiv eingeschaltet.
|
||||
* Variante 2: Die Wärmepumpe (Verdichter und elektrische Zusatzheizungen) wird aktiv eingeschaltet, optional: höhere Temperatur in den Wärmespeichern
|
||||
* Operating state 4 (Relay state 1: 1):
|
||||
* This is a definitive start-up command, insofar as this is possible within the framework of the rule settings.
|
||||
* For this operating state, different control models must be set on the controller for different tariff and usage models:
|
||||
* Variant 1: The heat pump (compressor) is actively switched on.
|
||||
* Variant 2: The heat pump (compressor and electrical auxiliary heating) is actively switched on, optional: higher temperature in the heat storage
|
||||
*/
|
||||
return 4;
|
||||
}
|
||||
|
|
|
|||
Loading…