Patrick Schurig
89406495a8 sunspec: add Fronius vendor with its own control rules
Adds a fronius vendor and a froniusConnection thing class alongside the
generic sunspec and solarEdge ones, following the SolarEdge mechanism but
none of its workarounds - no proprietary battery block and no PV
production computed by difference, since the GEN24 exposes model 160.

FroniusRules holds the vendor decisions as pure functions:

  - discovery only keeps devices announcing Fronius as manufacturer;
  - the byte order is the SunSpec default, not the forced big endian that
    is specific to SolarEdge, and no endianness parameter is exposed;
  - meterSlaveId defaults to 200, 0 meaning no meter on this connection;
  - a hard 7 s floor on the poll interval. Polling faster can push the
    inverter offline towards the vendor portal, and recovery needs an
    AC+DC power cycle on site, so this is a guard in the code rather than
    a configurable default;
  - the registers the inverter accepts and then silently ignores are
    refused before anything reaches the wire;
  - the six HEMS battery modes map onto ChaGriSet, StorCtl_Mod, InWRte and
    OutWRte, negative meaning charge;
  - model 160 blocks are classified by IDStr, never by index: on a three
    or four MPPT inverter the battery blocks are not in position 3 and 4.

Storages under a Fronius connection default revertTime to 300 s.

Setpoints now reread the scale factor before writing and read the written
registers back afterwards, reporting a mismatch through a new
controlHealthy state - the only defence against writes that are accepted
and then ignored without a Modbus exception.

Byte order and the revert timer semantics on model 124 are inferences, not
measurements; see specs/fronius-sunspec.md, H-2 and H-3.
2026-07-31 10:33:12 +02:00
Patrick Schurig
c5c3f46f57 sunspec: arm the storage revert timer after every setpoint
setInOutWRteRvrtTms() existed but was never called. InOutWRte_RvrtTms is
the delay after which the inverter drops the setpoint and resumes its
native behaviour. Left at 0, a setpoint stays active indefinitely, HEMS
stopped, network lost or process crashed included - the battery stays
where the last command put it.

Add a per-thing revertTime parameter, 0..28800 s, defaulting to 0 so the
generic vendor keeps its current behaviour, and route every setpoint
through SunSpecStorageLogic::planSetpoint(). The plan orders the writes -
ChaGriSet, StorCtl_Mod, then the rates - and appends the revert timer
last, so the timer never starts counting against a setpoint that has not
been written yet.

Writes are issued sequentially rather than in parallel: the order is part
of the contract with the hardware.
2026-07-31 10:26:01 +02:00
Patrick Schurig
4ec7aa50e8 sunspec: reconcile storage states from the registers actions write
onStorageBlockUpdated() fed chargingRate from wChaGra() and dischargingRate
from wDisChaGra(). Those are the gradients, in percent of WChaMax per
second, and read only on several inverters. The matching actions write
InWRte and OutWRte, in percent of WChaMax. The user wrote one quantity and
read back another.

Feed the two rate states from inWRte() and outWRte(), and keep the
gradients under names that cannot be mistaken for setpoints:
chargeGradient and dischargeGradient, read only.

enableDischarging was never reconciled either, while enableCharging was.
It stayed frozen on the last written value and drifted silently as soon as
the inverter changed StorCtl_Mod on its own. Reconcile both flags.

The mapping moves into SunSpecStorageLogic so it can be exercised on a
register dump without a running nymea.
2026-07-31 10:22:44 +02:00
Patrick Schurig
bb842eea55 sunspec: vendor plugin sources from nymea-plugins-modbus 1.15.2
Vendor the sunspec plugin into this repo so the Fronius work and the
upstream storage fixes can live here. Sources only: build artefacts and
generated plugininfo headers are excluded.

libnymea-sunspec is deliberately NOT vendored - the plugin must stay
rebasable on upstream nymea, so it links against libnymea-sunspec-dev.
sunspec.pri resolves it via pkg-config, with a NYMEA_SUNSPEC_PATH
override for a local sysroot, mirroring modbus.pri.

See sunspec/VENDORED.md.