A GEN24 answers for the inverter on one unit ID and for the Smart Meter
on another, behind the same host and port. Isolate the decision to open
that second connection as a pure function, so it can be pinned down
without nymea, and leave the logging of the refusal to the caller.
Refuses a meter slave ID out of the 0..247 range, treats 0 as "no meter
on this connection" as documented, and refuses a meter slave ID equal to
the inverter one: a second socket on the same unit ID would rediscover
the very same models and duplicate every child thing. That last case is
reachable, since the discovery writes the scanned slave ID into the
thing parameter.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The existing suite only exercises free functions and the plugin JSON, so it
cannot see whether a thing class is dispatched at all. A thing class missing
from the dispatch in setupThing() falls into the final Q_ASSERT_X: in a debug
build the process dies, in a release build the assert is compiled out and
setupThing() returns without ever calling info->finish(), leaving the pairing
stuck with no message.
Split the tests into two suites. The logic one keeps its former scope and its
single dependency on libnymea-sunspec. The new one instantiates the plugin
behind the real ThingManager of libnymea-core and a faked HardwareManager, so
the dispatch of setupThing(), postSetupThing() and thingRemoved() is covered.
No network access takes place: the faked monitor is never reachable, so the
plugin never attempts a Modbus connection.
The four new cases fail: froniusConnection is not dispatched yet.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>