Build fixes found during first local compilation (qmake6 + g++ -Werror):
1. Logging category: nymea-plugininfocompiler generates 'dcV2C' (uppercase C)
from the JSON vendor name "V2C". All three source files used 'dcV2c'
(lowercase c) — corrected to 'dcV2C' in integrationpluginv2c.cpp,
trydanmodbustcpmaster.cpp, v2ctcpdiscovery.cpp.
2. modbus.pri: hardcoded include(/usr/include/nymea-modbus/modbus-tool.pri)
fails when libnymea-modbus-dev is not system-installed. Changed to a
conditional: checks $$[QT_INSTALL_PREFIX] first, then NYMEA_MODBUS_PATH
override, with a graceful fallback (warning + manual C++17 CONFIG flag).
The v2c plugin has MODBUS_CONNECTIONS empty so the tool loop is a no-op
either way; the fallback is safe.
3. debian/: add powersync-plugin-v2c package entry (control, .install,
changelog entry 1.15.0+etm4).
Build verified: libnymea_integrationpluginv2c.so links against libnymea.so.1,
libnymea-modbus.so.1, Qt6Network/SerialBus/Core, 0 compiler warnings
(with -Werror -Wall -Wextra -std=c++17).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
qMin(32, m_maxIntensity) gives 0 when firmware returns 0 for MaxIntensity
(aberrant value). maxIntensity()==0 then causes every setMaxChargingCurrent
call to be clamped to 0, falling into the <6 A path which pauses charging
silently — the user sees the action succeed but the charger stops.
qBound(6, val, 32) is correct in all cases:
- firmware reports 16 A (mono Trydan) → 16 (real installation limit kept)
- firmware reports 0 (aberrant) → 6 (safe floor, does not claim 32 A)
- firmware reports 65535 (aberrant) → 32 (IEC absolute ceiling)
The real installation limit still comes from MaxIntensity read on the device;
the bounds [6, 32] are only IEC guardrails, not hardcoded defaults.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Architecture choice: separate the register map / business logic from the
physical transport. TrydanModbusMaster (abstract QObject) holds:
- the complete ReadRegister / WriteRegister enums with addresses
- float32 Big/Big decode helpers (memcpy pattern, matches pymodbus
BinaryPayloadDecoder byteorder=Endian.Big wordorder=Endian.Big)
- all last-polled cached values accessible via simple getters
TrydanModbusTcpMaster (concrete, Étape 1) wraps libnymea-modbus
ModbusTcpMaster. Each register read is a distinct FC3(addr, 2)
transaction via a recursive runReadSequence/doNextRead pattern —
never a block read, because the V2C firmware's register windows
overlap (0x0BC2 and 0x0BC3 each span 2 registers, so a range read
starting at 0x0BC2 for ≥3 registers returns garbage for the second
value). Writes use FC6 (single uint16, not float).
writeCompleted(quint16 address, bool success) carries the originating
register address so that concurrent background writes (e.g. PauseDynamic
from the conflict manager firing during an action) do not interfere with
action handlers waiting on a specific register's acknowledgement.
0x177E (Dynamic) is intentionally absent from WriteRegister: writing it
to 0 silences ChargePower telemetry even though the charger keeps running.
cf. evcc charger/trydan.go and github.com/evcc-io/evcc/issues/28047.
Étape 2 (RTU) will add TrydanModbusRtuMaster on the same interface;
no changes to plugin or register logic will be required.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>