chore(release): 1.15.2+etm13
Les deux correctifs V2C de la campagne du 2026-08-28 : sessionEnergy construit par accumulation, et les registres 0x0BD9-0x0BDB republiés en ampères. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01A41CTzMvir1Y5ABPXW8xpB
This commit is contained in:
parent
0798b2937d
commit
32779b39f4
42
debian/changelog
vendored
42
debian/changelog
vendored
@ -1,3 +1,45 @@
|
||||
etm-powersync-plugins-modbus (1.15.2+etm13) trixie; urgency=medium
|
||||
|
||||
* v2c: sessionEnergy is now BUILT by the plugin, not wired to a register.
|
||||
|
||||
The Trydan publishes no session energy. Its ChargeEnergy counter (0x0BC4)
|
||||
is accurate -- integrating it matches currentPower to better than one
|
||||
percent, twice over -- but it is not conserved: the firmware zeroes it on
|
||||
every CHARGE STOP, cable still plugged in. Measured cycle: stop at t+1 s,
|
||||
zeroed at t+8 s, unplug only at t+127 s. The trigger is the stop, not the
|
||||
unplug.
|
||||
|
||||
That makes it our problem, not the firmware's: under surplus control it is
|
||||
our own arbitration that cuts when a cloud passes. The HEMS would erase its
|
||||
own measurement several times a day, and an overnight charge read back at
|
||||
07:00 would be 0 -- "nothing delivered", which LM-1009 condition C1 forbids
|
||||
displaying.
|
||||
|
||||
The plugin accumulates the increments before each reset. In the plugin and
|
||||
not in the engine: the plugin polls at 30 s, the engine at one minute, so an
|
||||
increment erased between two engine reads would be invisible to it. Reset
|
||||
happens when a session OPENS, never when it closes, so the total stays
|
||||
readable in the morning once the car has gone. Unplug is confirmed over 3
|
||||
SUCCESSFUL polls; failed polls are not counted, so a WiFi outage freezes the
|
||||
absence counter instead of advancing it. State survives a nymead restart via
|
||||
two cached states plus a transition-only flag in pluginStorage().
|
||||
|
||||
chargeEnergy stays published alongside under its exact name -- the raw
|
||||
charger counter next to the built quantity. Only its displayName changes.
|
||||
|
||||
* v2c: registers 0x0BD9-0x0BDB carry AMPERES, not watts.
|
||||
|
||||
V2C's sheet labels them "Power_L1/L2/L3". Measured: a 6 A setpoint reads
|
||||
5.9-6.0, a 10 A setpoint reads 9.x-10. At 230 V a phase power would be
|
||||
~1380 W, not 5.9. Published as Watt, the app showed "5.9 W" where the
|
||||
charger says "5.9 A". States renamed currentL1/L2/L3, unit Ampere; the
|
||||
UUIDs do NOT change, as the identifier always carried amperes -- it was the
|
||||
name that lied. Side benefit: per-phase imbalance, which no other charger in
|
||||
the catalogue provides, useful for the per-phase overload ceiling
|
||||
(LM-1006-1).
|
||||
|
||||
-- Patrick Schurig <etm.schurig@gmail.com> Fri, 28 Aug 2026 14:30:00 +0200
|
||||
|
||||
etm-powersync-plugins-modbus (1.15.2+etm12) trixie; urgency=medium
|
||||
|
||||
* v2c: the Trydan now declares phaseCount, and it is ENTERED at pairing.
|
||||
|
||||